A high-resolution radiographic method for soft tissues in the small joints of the hand would aid in the study and treatment of rheumatoid arthritis (RA) and osteoarthritis (OA), which often attacks these joints. Of particular interest would be imaging with <100 µm resolution the joint cartilage, whose integrity is a main indicator of disease. Differential phase-contrast (DPC) or refraction-based x-ray imaging with Talbot grating interferometers could provide such a method, since it enhances soft tissue contrast and can be implemented with conventional x-ray tubes. A numerical joint phantom was first developed to assess the angular sensitivity and spectrum needed for a hand DPC system. The model predicts that, due to quite similar refraction indexes for joint soft tissues, the refraction effects are very small, requiring high angular resolution. To compare our model to experiment we built a high-resolution bench-top interferometer using 10 µm period gratings, a W anode tube and a CCD-based detector. Imaging experiments on animal cartilage and on a human finger support the model predictions. For instance, the estimated difference between the index of refraction of cartilage and water is of only several percent at ∼25 keV mean energy, comparable to that between the linear attenuation coefficients. The potential advantage of DPC imaging thus comes mainly from the edge enhancement at the soft tissue interfaces. Experiments using a cadaveric human finger are also qualitatively consistent with the joint model, showing that refraction contrast is dominated by tendon embedded in muscle, with the cartilage layer difficult to observe in our conditions. Nevertheless, the model predicts that a DPC radiographic system for the small hand joints of the hand could be feasible using a low energy quasi-monochromatic source, such as a K-edge filtered Rh or Mo tube, in conjunction with a ∼2 m long 'symmetric' interferometer operated in a high Talbot order.
A high-resolution n class="Disease">ran>diographic method for soft tissues in the small joints of the hand would aid in the study and treatment of rheumatoid arthritis (RA) and osteoarthritis (OA), which often attacks these joints. Of particular interest would be imaging with <100 µm resolution the joint cartilage, whose integrity is a main indicator of disease. Differential phase-contrast (DPC) or refraction-based x-ray imaging with Talbot grating interferometers could provide such a method, since it enhances soft tissue contrast and can be implemented with conventional x-ray tubes. A numerical joint phantom was first developed to assess the angular sensitivity and spectrum needed for a hand DPC system. The model predicts that, due to quite similar refraction indexes for joint soft tissues, the refraction effects are very small, requiring high angular resolution. To compare our model to experiment we built a high-resolution bench-top interferometer using 10 µm period gratings, a W anode tube and a CCD-based detector. Imaging experiments on animalcartilage and on a human finger support the model predictions. For instance, the estimated difference between the index of refraction of cartilage and water is of only several percent at ∼25 keV mean energy, comparable to that between the linear attenuation coefficients. The potential advantage of DPC imaging thus comes mainly from the edge enhancement at the soft tissue interfaces. Experiments using a cadaveric human finger are also qualitatively consistent with the joint model, showing that refraction contrast is dominated by tendon embedded in muscle, with the cartilage layer difficult to observe in our conditions. Nevertheless, the model predicts that a DPCradiographic system for the small hand joints of the hand could be feasible using a low energy quasi-monochromatic source, such as a K-edge filtered Rh or Mo tube, in conjunction with a ∼2 m long 'symmetric' interferometer operated in a high Talbot order.
Authors: Jani Keyriläinen; Alberto Bravin; Manuel Fernández; Mikko Tenhunen; Pekka Virkkunen; Pekka Suortti Journal: Acta Radiol Date: 2010-10 Impact factor: 1.990
Authors: Martin Bech; Oliver Bunk; Christian David; Ronald Ruth; Jeff Rifkin; Rod Loewen; Robert Feidenhans'l; Franz Pfeiffer Journal: J Synchrotron Radiat Date: 2008-11-27 Impact factor: 2.616
Authors: Paola Coan; Fabian Bamberg; Paul C Diemoz; Alberto Bravin; Kirsten Timpert; Elisabeth Mützel; Jose G Raya; Silvia Adam-Neumair; Maximilian F Reiser; Christian Glaser Journal: Invest Radiol Date: 2010-07 Impact factor: 6.016
Authors: M Fuerst; J Bertrand; L Lammers; R Dreier; F Echtermeyer; Y Nitschke; F Rutsch; F K W Schäfer; O Niggemeyer; J Steinhagen; C H Lohmann; T Pap; W Rüther Journal: Arthritis Rheum Date: 2009-09
Authors: Arne Tapfer; Martin Bech; Astrid Velroyen; Jan Meiser; Jürgen Mohr; Marco Walter; Joachim Schulz; Bart Pauwels; Peter Bruyndonckx; Xuan Liu; Alexander Sasov; Franz Pfeiffer Journal: Proc Natl Acad Sci U S A Date: 2012-09-10 Impact factor: 11.205
Authors: Guibin Zan; David John Vine; Wenbing Yun; Sylvia Jia Yun Lewis; Qiuping Wang; Ge Wang Journal: Phys Med Biol Date: 2020-02-04 Impact factor: 3.609
Authors: Johannes Bopp; Veronika Ludwig; Maria Seifert; Georg Pelzer; Andreas Maier; Gisela Anton; Christian Riess Journal: Int J Comput Assist Radiol Surg Date: 2018-10-22 Impact factor: 2.924
Authors: P R T Munro; M Endrizzi; P C Diemoz; C K Hagen; M B Szafraniec; T P Millard; C E Zapata; R D Speller; A Olivo Journal: Philos Trans A Math Phys Eng Sci Date: 2014-01-27 Impact factor: 4.226
Authors: Massimo Marenzana; Charlotte K Hagen; Patricia Das Neves Borges; Marco Endrizzi; Magdalena B Szafraniec; Tonia L Vincent; Luigi Rigon; Fulvia Arfelli; Ralf-Hendrik Menk; Alessandro Olivo Journal: Philos Trans A Math Phys Eng Sci Date: 2014-01-27 Impact factor: 4.226