Literature DB >> 20170875

Impact of multiple and long sirolimus-eluting stent implantation on 3-year clinical outcomes in the j-Cypher Registry.

Shinichi Shirai1, Takeshi Kimura, Masakiyo Nobuyoshi, Takeshi Morimoto, Kenji Ando, Yoshimitsu Soga, Kyohei Yamaji, Katsuhiro Kondo, Koyu Sakai, Takeshi Arita, Masahiko Goya, Masashi Iwabuchi, Hiroyoshi Yokoi, Hideyuki Nosaka, Kazuaki Mitsudo.   

Abstract

OBJECTIVES: Our aim was to study the relationships between total stent length (TSL) and long-term clinical outcomes after sirolimus-eluting stent (SES) implantation.
BACKGROUND: SES compared with bare-metal stent use for long lesion treatment is associated with reduced restenosis rates.
METHODS: Three-year follow-up data were available for 10,773 patients (14,651 lesions) that had been treated with only SES (Cypher, Cordis Corp., Warren, New Jersey) in the j-Cypher registry. Patients and lesions were divided into quartile groups: TSL per patient (Q1: 8 to 23 mm, Q2: 24 to 36 mm, Q3: 37 to 54 mm, Q4: 55 to 293 mm), and TSL per lesion (QA: 8 to 18 mm, QB: 19 to 23 mm, QC: 24 to 33 mm, QD: 34 to 150 mm).
RESULTS: In per-lesion data, longer TSL increased target lesion revascularization (TLR) rates but did not increase stent thrombosis rates (p = 0.2324). In per-patient data, the incidences of TLR remarkably increased with increasing TSL. Incidence of composite of death and myocardial infarction also increased with increasing TSL; however, after adjustment for baseline differences, there was no statistical significance. Definite stent thrombosis rate in group Q4 was significantly higher than in other groups, both unadjusted (hazard ratio: 1.770, p = 0.0081) and adjusted (hazard ratio: 1.727, p = 0.0122) for baseline differences.
CONCLUSIONS: TSL per lesion and patient had significantly impacts on TLR rates. Longer TSL per patient was associated with increased incidence of stent thrombosis through 3 years. Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20170875     DOI: 10.1016/j.jcin.2009.11.009

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  10 in total

1.  Scanning electron microscopic analysis of polymer damage in drug-eluting stents during multiple stenting.

Authors:  Aiko Shimokado; Takashi Kubo; Hirotoshi Utsunomiya; Hisashi Yamasaki; Takashi Tanimoto; Yasushi Ino; Yong Liu; Ikuko Teraguchi; Yuichi Ozaki; Yasutsugu Shiono; Makoto Orii; Kunihiro Shimamura; Takashi Yamano; Tomoyuki Yamaguchi; Kumiko Hirata; Toshio Imanishi; Takashi Akasaka
Journal:  Int J Cardiovasc Imaging       Date:  2013-09-13       Impact factor: 2.357

2.  Calibration-free device sizing using an inverse geometry x-ray system.

Authors:  Michael T Tomkowiak; Michael A Speidel; Amish N Raval; Michael S Van Lysel
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

3.  Influence of hemodialysis duration on mid-term clinical outcomes in hemodialysis patients with coronary artery disease after drug-eluting stent implantation.

Authors:  Norihiro Kobayashi; Toshiya Muramatsu; Reiko Tsukahara; Yoshiaki Ito; Hiroshi Ishimori; Keisuke Hirano; Masatsugu Nakano; Masahiro Yamawaki; Motoharu Araki; Hideyuki Takimura; Yasunari Sakamoto
Journal:  Heart Vessels       Date:  2014-12-19       Impact factor: 2.037

4.  Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation.

Authors:  Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel; Tobias Funk; Michael A Speidel
Journal:  J Med Imaging (Bellingham)       Date:  2014-10

5.  Calibration-Free Coronary Artery Measurements for Interventional Device Sizing using Inverse Geometry X-ray Fluoroscopy: In Vivo Validation.

Authors:  Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel; Tobias Funk; Michael A Speidel
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-19

6.  Impact of lesion complexity on long-term vascular response to cobalt-chromium everolimus-eluting stent: five-year follow-up optical coherence tomography study.

Authors:  Shoichi Kuramitsu; Shinjo Sonoda; Tomohiro Shinozaki; Hiroyuki Jinnouch; Yoshitaka Muraoka; Takenori Domei; Makoto Hyodo; Shinichi Shirai; Kenji Ando; Yutaka Otsuji
Journal:  Heart Vessels       Date:  2017-10-19       Impact factor: 2.037

7.  Very Late Stent Thrombosis of Sirolimus-eluting Stent 59 Months After Implantation: A First Report from The Middle-East and Review of Literature.

Authors:  Prashanth Panduranga; Mohammed Al-Mukhaini
Journal:  Heart Views       Date:  2011-01

Review 8.  Clinical Outcomes of Successful Revascularization of Chronic Total Coronary Occlusions with Bioresorbable Vascular Scaffolds: A Systematic Review.

Authors:  Roman Marchenko; Salik Nazir; Shelina Malla; Anthony Donato
Journal:  Cureus       Date:  2018-11-28

9.  Association of Second-Generation Drug-Eluting Stent Length With 2-Year Adverse Clinical Outcomes Among Japanese Patients With Ischemic Heart Disease.

Authors:  Kentaro Ejiri; Mitsuaki Sawano; Yohei Numasawa; Shigetaka Noma; Hiroshi Ito; Keiichi Fukuda; Shun Kohsaka
Journal:  JAMA Netw Open       Date:  2020-08-03

10.  Lesion length impacts long term outcomes of drug-eluting stents and bare metal stents differently.

Authors:  Shang-Hung Chang; Chun-Chi Chen; Ming-Jer Hsieh; Chao-Yung Wang; Cheng-Hung Lee; I-Chang Hsieh
Journal:  PLoS One       Date:  2013-01-11       Impact factor: 3.240

  10 in total