Literature DB >> 20161147

Effectiveness of Intravenous Infusion Algorithms for Glucose Control in Diabetic Patients Using Different Simulation Models.

Terry G Farmer1, Thomas F Edgar, Nicholas A Peppas.   

Abstract

The effectiveness of closed-loop insulin infusion algorithms is assessed for three different mathematical models describing insulin and glucose dynamics within a Type I diabetes patient. Simulations are performed to assess the effectiveness of proportional plus integral plus derivative (PID) control, feedforward control, and a physiologically-based control system with respect to maintaining normal glucose levels during a meal and during exercise. Control effectiveness is assessed by comparing the simulated response to a simulation of a healthy patient during both a meal and exercise and establishing maximum and minimum glucose levels and insulin infusion levels, as well as maximum duration of hyperglycemia. Controller effectiveness is assessed within the minimal model, the Sorensen model, and the Hovorka model. Results showed that no type of control was able to maintain normal conditions when simulations were performed using the minimal model. For both the Sorensen model and the Hovorka model, proportional control was sufficient to maintain normal glucose levels. Given published clinical data showing the ineffectiveness of PID control in patients, the work demonstrates that controller success based on simulation results can be misleading, and that future work should focus on addressing the model discrepancies.

Entities:  

Year:  2009        PMID: 20161147      PMCID: PMC2732993          DOI: 10.1021/ie800871t

Source DB:  PubMed          Journal:  Ind Eng Chem Res        ISSN: 0888-5885            Impact factor:   3.720


  20 in total

Review 1.  The intravenous route to blood glucose control.

Authors:  R S Parker; F J Doyle; N A Peppas
Journal:  IEEE Eng Med Biol Mag       Date:  2001 Jan-Feb

Review 2.  Closed-loop insulin delivery-the path to physiological glucose control.

Authors:  G M Steil; A E Panteleon; K Rebrin
Journal:  Adv Drug Deliv Rev       Date:  2004-02-10       Impact factor: 15.470

3.  A model-based algorithm for blood glucose control in type I diabetic patients.

Authors:  R S Parker; F J Doyle; N A Peppas
Journal:  IEEE Trans Biomed Eng       Date:  1999-02       Impact factor: 4.538

4.  On-line adaptive algorithm with glucose prediction capacity for subcutaneous closed loop control of glucose: evaluation under fasting conditions in patients with Type 1 diabetes.

Authors:  H C Schaller; L Schaupp; M Bodenlenz; M E Wilinska; L J Chassin; P Wach; T Vering; R Hovorka; T R Pieber
Journal:  Diabet Med       Date:  2006-01       Impact factor: 4.359

5.  Multicentric, randomized, controlled trial to evaluate blood glucose control by the model predictive control algorithm versus routine glucose management protocols in intensive care unit patients.

Authors:  Johannes Plank; Jan Blaha; Jeremy Cordingley; Malgorzata E Wilinska; Ludovic J Chassin; Cliff Morgan; Stephen Squire; Martin Haluzik; Jaromir Kremen; Stepan Svacina; Wolfgang Toller; Andreas Plasnik; Martin Ellmerer; Roman Hovorka; Thomas R Pieber
Journal:  Diabetes Care       Date:  2006-02       Impact factor: 19.112

6.  Partitioning glucose distribution/transport, disposal, and endogenous production during IVGTT.

Authors:  Roman Hovorka; Fariba Shojaee-Moradie; Paul V Carroll; Ludovic J Chassin; Ian J Gowrie; Nicola C Jackson; Romulus S Tudor; A Margot Umpleby; Richard H Jones
Journal:  Am J Physiol Endocrinol Metab       Date:  2002-05       Impact factor: 4.310

7.  Feedback control dynamics for glucose controlled insulin infusion system.

Authors:  A H Clemens
Journal:  Med Prog Technol       Date:  1979-06-15

8.  Overestimation of minimal model glucose effectiveness in presence of insulin response is due to undermodeling.

Authors:  C Cobelli; F Bettini; A Caumo; M J Quon
Journal:  Am J Physiol       Date:  1998-12

9.  Substrate turnover during prolonged exercise in man. Splanchnic and leg metabolism of glucose, free fatty acids, and amino acids.

Authors:  G Ahlborg; P Felig; L Hagenfeldt; R Hendler; J Wahren
Journal:  J Clin Invest       Date:  1974-04       Impact factor: 14.808

10.  Blood glucose control by intermittent loop closure in the basal mode: computer simulation studies with a diabetic model.

Authors:  S M Furler; E W Kraegen; R H Smallwood; D J Chisholm
Journal:  Diabetes Care       Date:  1985 Nov-Dec       Impact factor: 19.112

View more
  1 in total

1.  Optimal design of clinical tests for the identification of physiological models of type 1 diabetes in the presence of model mismatch.

Authors:  Federico Galvanin; Massimiliano Barolo; Sandro Macchietto; Fabrizio Bezzo
Journal:  Med Biol Eng Comput       Date:  2010-11-30       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.