Feedback control dynamics for glucose controlled insulin infusion system.

A H Clemens.   

Abstract

Miles Laboratories has developed a Glucose Controlled Insulin Infusion System (GCIIS) designated by the Trademark (BIOSTATOR) as a tool to investigate the physiologic control parameters of carbohydrate metabolism and regulatory deficiencies in diabetes. It consists, in principle, of a rapid on-line glucose analyzer, a computer/controller for the calculation and control of insulin or dextrose infusion, and a multichannel infusion system. A silent printer records, on a minute-by-minute basis, the glucose value measured, the insulin and/or dextrose infusion rates, and the cumulative total of the insulin infused. The on-line glucose analyzer employs an electrochemical sensor with immobilized glucose oxidase and measures the hydrogen peroxide produced. Its linearity extends beyond 700 mg/dl glucose; it permits a rapid two-point calibration of the sensor and the overall calibration of the on-line analyzer without disconnecting the catheter from the patient. The system's response time, including blood sample transport from the patient, is less than 90 seconds with a blood loss of approximately 50 ml per 24 h. The insulin and dextrose infusions are governed by control algorithms; various mathematical models have been developed and employed toward improved feedback control dynamics. The rapid glucose analyzer eliminates the need for the calculation of a "predicted" glucose value and permits, instead, the use of a derivative function for dynamic control. A multichannel infusion system combines the principles of a peristaltic pump with the advantages of a precision pump performance and individual computer control for each of the pump channels.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 481365

Source DB:  PubMed          Journal:  Med Prog Technol        ISSN: 0047-6552


  19 in total

Review 1.  The future of open- and closed-loop insulin delivery systems.

Authors:  Terry G Farmer; Thomas F Edgar; Nicholas A Peppas
Journal:  J Pharm Pharmacol       Date:  2008-01       Impact factor: 3.765

2.  Engineering implications of closed-loop control during cardiac surgery.

Authors:  A V Sebald; M Quinn; N T Smith; A Karimi; G Schnurer; S Isaka
Journal:  J Clin Monit       Date:  1990-07

3.  Adaptive closed-loop control provides blood-glucose regulation using dual subcutaneous insulin and glucagon infusion in diabetic Swine.

Authors:  Firas H El-Khatib; John Jiang; Edward R Damiano
Journal:  J Diabetes Sci Technol       Date:  2007-03

4.  Effects of glucagon on plasma amino acids.

Authors:  G Boden; I Rezvani; O E Owen
Journal:  J Clin Invest       Date:  1984-03       Impact factor: 14.808

Review 5.  Glucose clamp algorithms and insulin time-action profiles.

Authors:  B Wayne Bequette
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

6.  Design of an Artificial Pancreas using Zone Model Predictive Control with a Moving Horizon State Estimator.

Authors:  Justin J Lee; Ravi Gondhalekar; Francis J Doyle
Journal:  Proc IEEE Conf Decis Control       Date:  2015-02-12

7.  Periodic zone-MPC with asymmetric costs for outpatient-ready safety of an artificial pancreas to treat type 1 diabetes.

Authors:  Ravi Gondhalekar; Eyal Dassau; Francis J Doyle
Journal:  Automatica (Oxf)       Date:  2016-06-01       Impact factor: 5.944

8.  In silico preclinical trials: a proof of concept in closed-loop control of type 1 diabetes.

Authors:  Boris P Kovatchev; Marc Breton; Chiara Dalla Man; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2009-01

9.  Multi-objective blood glucose control for type 1 diabetes.

Authors:  Pinky Dua; Francis J Doyle; Efstratios N Pistikopoulos
Journal:  Med Biol Eng Comput       Date:  2009-02-13       Impact factor: 2.602

10.  Analysis of algorithms for intensive care unit blood glucose control.

Authors:  B Wayne Bequette
Journal:  J Diabetes Sci Technol       Date:  2007-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.