Literature DB >> 20149579

Minimum 5-year follow-up of a cementless, modular, tapered stem in hip revision arthroplasty.

Rüdiger J Weiss1, Mats O Beckman, Anders Enocson, Anders Schmalholz, André Stark.   

Abstract

Hip revision surgery with a cementless tapered femoral component can provide axial and rotational stability in patients with compromised proximal bone stock. This study includes 90 cases revised with the Link MP (Waldemar Link, Hamburg, Germany) prosthesis. The median age at surgery was 72 (38-89) years. Aseptic loosening (70%) and periprosthetic fracture (22%) were common indications for surgery. Sixty-three patients (70%) were followed clinically with a median of 6 (5-11) years of follow-up. All other patients were followed through the Swedish Hip Register. The 5-year survival rate was 98% with stem removal and 90% with any reoperation as the end point. Complications included hip dislocation in 17 (19%) patients. The median Harris hip score was 78 (16-100) points, and the median radiographic stem migration was 2.7 mm at follow-up.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20149579     DOI: 10.1016/j.arth.2009.11.009

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  28 in total

Review 1.  Management of periprosthetic femoral fractures following total hip arthroplasty: a review.

Authors:  Matthew P Abdel; Umberto Cottino; Tad M Mabry
Journal:  Int Orthop       Date:  2015-08-29       Impact factor: 3.075

2.  [Cement-free and cemented Excia hip shaft prosthesis: comparison of intermediate term results].

Authors:  C Urschel; M Döring; W Strecker
Journal:  Orthopade       Date:  2014-09       Impact factor: 1.087

3.  CORR Insights®: modular tapered implants for severe femoral bone loss in THA: reliable osseointegration but frequent complications.

Authors:  Curtis W Hartman
Journal:  Clin Orthop Relat Res       Date:  2014-09-09       Impact factor: 4.176

4.  Revision total hip arthroplasty using a cementless tapered revision stem in patients with a mean age of 82 years.

Authors:  Daniel Neumann; Lothar Dueckelmann; Christoph Thaler; Ulrich Dorn
Journal:  Int Orthop       Date:  2011-10-26       Impact factor: 3.075

5.  Revision hip arthroplasty with a rectangular tapered cementless stem: a retrospective study of the SLR-Plus stem at a mean follow-up of 4.1 years.

Authors:  Iker Uriarte; Jesús Moreta; Laura Cortés; Lucía Bernuy; Urko Aguirre; José Luis Martínez de Los Mozos
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-10-15

6.  Distal non-traumatic fracture of the cementless MP stem: A case report and review of previous reported cases.

Authors:  Hussein Abdelaziz; Christian Ansorge; Thorsten Gehrke; Mustafa Citak
Journal:  J Clin Orthop Trauma       Date:  2019-07-30

7.  Acetabular liner with focal constraint to prevent dislocation after THA.

Authors:  Jacob T Munro; Mihai H Vioreanu; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

8.  Periprosthetic femur fractures treated with modular fluted, tapered stems.

Authors:  Matthew P Abdel; David G Lewallen; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

9.  Tapered fluted titanium stems in the management of Vancouver B2 and B3 periprosthetic femoral fractures.

Authors:  Jacob T Munro; Donald S Garbuz; Bassam A Masri; Clive P Duncan
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

10.  Modular tapered implants for severe femoral bone loss in THA: reliable osseointegration but frequent complications.

Authors:  Nicholas M Brown; Matthew Tetreault; Cara A Cipriano; Craig J Della Valle; Wayne Paprosky; Scott Sporer
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.