Literature DB >> 20138501

A technique for stereotactic radiosurgery treatment planning with helical tomotherapy.

Emilie T Soisson1, Peter W Hoban, Thomas Kammeyer, Jeffrey M Kapatoes, David C Westerly, Amar Basavatia, Wolfgang A Tomé.   

Abstract

The purpose of this study was to develop an efficient and effective planning technique for stereotactic radiosurgery using helical tomotherapy. Planning CTs and contours of 20 patients, previously treated in our clinic for brain metastases with linac-based radiosurgery using circular collimators, were used to develop a robust TomoTherapy planning technique. Plan calculation times as well as delivery times were recorded for all patients to allow for an efficiency evaluation. In addition, conformation and homogeneity indices were calculated as metrics to compare plan quality with that which is achieved with conventional radiosurgery delivery systems. A robust and efficient planning technique was identified to produce plans of radiosurgical quality using the TomoTherapy treatment planning system. Dose calculation did not exceed a few hours and resulting delivery times were less than 1 hour, which allows the process to fit into a single day radiosurgery workflow. Plan conformity compared favorably with published results for gamma knife radiosurgery. In addition, plan homogeneity was similar to linac-based approaches. The TomoTherapy planning software can be used to create plans of acceptable quality for stereotactic radiosurgery in a time that is appropriate for a radiosurgery workflow that requires that planning and delivery occur within 1 treatment day.
Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 20138501      PMCID: PMC2892558          DOI: 10.1016/j.meddos.2009.11.003

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  15 in total

1.  Development of a model to predict permanent symptomatic postradiosurgery injury for arteriovenous malformation patients. Arteriovenous Malformation Radiosurgery Study Group.

Authors:  J C Flickinger; D Kondziolka; L D Lunsford; A Kassam; L K Phuong; R Liscak; B Pollock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-03-15       Impact factor: 7.038

2.  A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note.

Authors:  I Paddick
Journal:  J Neurosurg       Date:  2000-12       Impact factor: 5.115

3.  Dose conformity of gamma knife radiosurgery and risk factors for complications.

Authors:  J L Nakamura; L J Verhey; V Smith; P L Petti; K R Lamborn; D A Larson; W M Wara; M W McDermott; P K Sneed
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-12-01       Impact factor: 7.038

4.  On the making of sharp longitudinal dose profiles with helical tomotherapy.

Authors:  Michael W Kissick; Ryan T Flynn; David C Westerly; Thomas Rockwell Mackie; Peter W Hoban
Journal:  Phys Med Biol       Date:  2007-10-16       Impact factor: 3.609

5.  Quality assurance of an image guided intracranial stereotactic positioning system.

Authors:  Emilie T Soisson; Geoff Sobering; Daniel Lucas; Edward Chao; Gustavo Olivera; Wolfgang A Tomé
Journal:  Technol Cancer Res Treat       Date:  2009-02

6.  Stereotactic image-guided intensity modulated radiotherapy using the HI-ART II helical tomotherapy system.

Authors:  Timothy W Holmes; Richard Hudes; Sylwester Dziuba; Abdul Kazi; Mark Hall; Dana Dawson
Journal:  Med Dosim       Date:  2008-04-01       Impact factor: 1.482

7.  Whole brain radiotherapy with hippocampal avoidance and simultaneously integrated brain metastases boost: a planning study.

Authors:  Alonso N Gutiérrez; David C Westerly; Wolfgang A Tomé; Hazim A Jaradat; Thomas R Mackie; Søren M Bentzen; Deepak Khuntia; Minesh P Mehta
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-10-01       Impact factor: 7.038

8.  Estimation of complications for linear accelerator radiosurgery with the integrated logistic formula.

Authors:  J C Flickinger; M C Schell; D A Larson
Journal:  Int J Radiat Oncol Biol Phys       Date:  1990-07       Impact factor: 7.038

9.  Target dose versus extratarget dose in stereotactic radiosurgery.

Authors:  I Lax
Journal:  Acta Oncol       Date:  1993       Impact factor: 4.089

10.  12 Gy gamma knife radiosurgical volume is a predictor for radiation necrosis in non-AVM intracranial tumors.

Authors:  Timothy Korytko; Tomas Radivoyevitch; Valdir Colussi; Barry W Wessels; Kunjan Pillai; Robert J Maciunas; Douglas B Einstein
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-10-14       Impact factor: 7.038

View more
  6 in total

1.  A dosimetric comparison between CyberKnife and tomotherapy treatment plans for single brain metastasis.

Authors:  Daniela Greto; Stefania Pallotta; Laura Masi; Cinzia Talamonti; Livia Marrazzo; Raffaella Doro; Calogero Saieva; Silvia Scoccianti; Isacco Desideri; Lorenzo Livi
Journal:  Radiol Med       Date:  2017-02-15       Impact factor: 3.469

2.  Optimal prescription isodose line in SBRT for lung tumor treatment with volumetric-modulated arc therapy.

Authors:  David Wang; Albert DeNittis; Tracey Evans; Thomas Meyer
Journal:  J Radiosurg SBRT       Date:  2020

3.  Evaluation of the target dose coverage of stereotactic body radiotherapy for lung cancer using helical tomotherapy: A dynamic phantom study.

Authors:  Masahide Saito; Hidekazu Suzuki; Naoki Sano; Kazunari Ashizawa; Kazuya Yoshizawa; Yuki Shibata; Koji Ueda; Takafumi Komiyama; Kan Marino; Shinichi Aoki; Ryo Saito; Yoshiyasu Maehata; Hiroshi Onishi
Journal:  Rep Pract Oncol Radiother       Date:  2020-01-14

4.  Intracranial Stereotactic Radiation Therapy With a Jawless Ring Gantry Linear Accelerator Equipped With New Dual Layer Multileaf Collimator.

Authors:  Nels C Knutson; William R Kennedy; Francisco J Reynoso; Jiayuan Peng; Lauren E Henke; Eric Laugeman; Michael Watts; Jessica Hillard; Ana Heermann; Geoffrey D Hugo; Sasa Mutic; Bin Cai
Journal:  Adv Radiat Oncol       Date:  2020-01-28

5.  The new SRS/FSRT technique HyperArc for benign brain lesions: a dosimetric analysis.

Authors:  Hsiu-Wen Ho; Ching-Chieh Yang; Hsiu-Man Lin; Hsiao-Yun Chen; Chun-Chiao Huang; Shih-Chang Wang; Yu-Wei Lin
Journal:  Sci Rep       Date:  2021-10-26       Impact factor: 4.379

6.  Strategies to optimize stereotactic radiosurgery plans for brain tumors with volumetric-modulated arc therapy.

Authors:  David Wang; Albert DeNittis; Yibing Hu
Journal:  J Appl Clin Med Phys       Date:  2020-02-11       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.