Literature DB >> 20136231

Ultrasound characterization of red blood cell aggregation with intervening attenuating tissue-mimicking phantoms.

Emilie Franceschini1, François T H Yu, François Destrempes, Guy Cloutier.   

Abstract

The analysis of the ultrasonic frequency-dependent backscatter coefficient of aggregating red blood cells reveals information about blood structural properties. The difficulty in applying this technique in vivo is due to the frequency-dependent attenuation caused by intervening tissue layers that distorts the spectral content of signals backscattered by blood. An optimization method is proposed to simultaneously estimate tissue attenuation and blood structure properties, and was termed the structure factor size and attenuation estimator (SFSAE). An ultrasound scanner equipped with a wide-band 25 MHz probe was used to insonify porcine blood sheared in both Couette and tubular flow devices. Since skin is one of the most attenuating tissue layers during in vivo scanning, four skin-mimicking phantoms with different attenuation coefficients were introduced between the transducer and the blood flow. The SFSAE gave estimates with relative errors below 25% for attenuations between 0.115 and 0.411 dBMHz and kR<2.08 (k being the wave number and R the aggregate radius). The SFSAE can be useful to examine in vivo and in situ abnormal blood conditions suspected to promote pathophysiological cardiovascular consequences.

Entities:  

Mesh:

Year:  2010        PMID: 20136231      PMCID: PMC2830269          DOI: 10.1121/1.3277200

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  24 in total

1.  High-frequency ultrasonic attenuation and backscatter coefficients of in vivo normal human dermis and subcutaneous fat.

Authors:  B I Raju; M A Srinivasan
Journal:  Ultrasound Med Biol       Date:  2001-11       Impact factor: 2.998

2.  Estimation of total attenuation and scatterer size from backscattered ultrasound waveforms.

Authors:  Timothy A Bigelow; Michael L Oelze; William D O'Brien
Journal:  J Acoust Soc Am       Date:  2005-03       Impact factor: 1.840

3.  Evaluation of the spectral fit algorithm as functions of frequency range and deltakaeff.

Authors:  Timothy A Bigelow; William D O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-11       Impact factor: 2.725

4.  Relationship of ultrasonic spectral parameters to features of tissue microstructure.

Authors:  F L Lizzi; M Ostromogilsky; E J Feleppa; M C Rorke; M M Yaremko
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1987       Impact factor: 2.725

5.  Simultaneous estimation of attenuation and structure parameters of aggregated red blood cells from backscatter measurements.

Authors:  Emilie Franceschini; François T H Yu; Guy Cloutier
Journal:  J Acoust Soc Am       Date:  2008-04       Impact factor: 1.840

6.  An approach for measuring ultrasonic backscattering from biological tissues with focused transducers.

Authors:  S H Wang; K K Shung
Journal:  IEEE Trans Biomed Eng       Date:  1997-07       Impact factor: 4.538

7.  Application of stochastic analysis to ultrasonic echoes--estimation of attenuation and tissue heterogeneity from peaks of echo envelope.

Authors:  P He; J F Greenleaf
Journal:  J Acoust Soc Am       Date:  1986-02       Impact factor: 1.840

8.  Relationship between collagen and ultrasonic backscatter in myocardial tissue.

Authors:  M O'Donnell; J W Mimbs; J G Miller
Journal:  J Acoust Soc Am       Date:  1981-02       Impact factor: 1.840

9.  Ultrasound attenuation and texture analysis of diffuse liver disease: methods and preliminary results.

Authors:  B J Oosterveld; J M Thijssen; P C Hartman; R L Romijn; G J Rosenbusch
Journal:  Phys Med Biol       Date:  1991-08       Impact factor: 3.609

10.  Identifying acoustic scattering sources in normal renal parenchyma in vivo by varying arterial and ureteral pressures.

Authors:  M F Insana; J G Wood; T J Hall
Journal:  Ultrasound Med Biol       Date:  1992       Impact factor: 2.998

View more
  15 in total

1.  Assessment of accuracy of the structure-factor-size-estimator method in determining red blood cell aggregate size from ultrasound spectral backscatter coefficient.

Authors:  Ratan K Saha; Emilie Franceschini; Guy Cloutier
Journal:  J Acoust Soc Am       Date:  2011-04       Impact factor: 1.840

2.  On the estimation of backscatter coefficients using single-element focused transducers.

Authors:  Roberto J Lavarello; Goutam Ghoshal; Michael L Oelze
Journal:  J Acoust Soc Am       Date:  2011-05       Impact factor: 1.840

3.  Lower Bound on Estimation Variance of the Ultrasonic Attenuation Coefficient Using the Spectral-Difference Reference-phantom Method.

Authors:  Kayvan Samimi; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2016-10-20       Impact factor: 1.578

4.  Low Variance Estimation of Backscatter Quantitative Ultrasound Parameters Using Dynamic Programming.

Authors:  Zara Vajihi; Ivan M Rosado-Mendez; Timothy J Hall; Hassan Rivaz
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-09-12       Impact factor: 2.725

5.  Predicting human blood viscosity in silico.

Authors:  Dmitry A Fedosov; Wenxiao Pan; Bruce Caswell; Gerhard Gompper; George E Karniadakis
Journal:  Proc Natl Acad Sci U S A       Date:  2011-07-05       Impact factor: 11.205

6.  Analysis of Two Quantitative Ultrasound Approaches.

Authors:  Pauline Muleki-Seya; Aiguo Han; Michael P Andre; John W Erdman; William D O'Brien
Journal:  Ultrason Imaging       Date:  2017-09-25       Impact factor: 1.578

7.  Effects of the container on structure function with impedance map analysis of dense scattering media.

Authors:  Adam C Luchies; Michael L Oelze
Journal:  J Acoust Soc Am       Date:  2018-04       Impact factor: 1.840

Review 8.  Computational Biomechanics of Human Red Blood Cells in Hematological Disorders.

Authors:  Xuejin Li; He Li; Hung-Yu Chang; George Lykotrafitis; George Em Karniadakis
Journal:  J Biomech Eng       Date:  2017-02-01       Impact factor: 2.097

9.  Optimum Diffraction-Corrected Frequency-Shift Estimator of the Ultrasonic Attenuation Coefficient.

Authors:  Kayvan Samimi; Tomy Varghese
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-03-04       Impact factor: 2.725

10.  Quantitative ultrasound estimates from populations of scatterers with continuous size distributions: effects of the size estimator algorithm.

Authors:  Roberto Lavarello; Michael Oelze
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-09       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.