Literature DB >> 1924541

Ultrasound attenuation and texture analysis of diffuse liver disease: methods and preliminary results.

B J Oosterveld1, J M Thijssen, P C Hartman, R L Romijn, G J Rosenbusch.   

Abstract

A study was performed to find and test quantitative methods of analysing echographic signals for the differentiation of diffuse liver diseases. An on-line data acquisition system was used to acquire radiofrequency (RF) echo signals from volunteers and patients. Several methods to estimate the frequency-dependent attenuation coefficient were evaluated, in which a correction for the frequency and depth-dependent diffraction and focusing effects caused by the sound beam was applied. Using the estimated value of the attenuation coefficient the RF signals themselves were corrected to remove the depth dependencies caused by the sound beam and by the frequency-dependent attenuation. After this preprocessing the envelope of the corrected RF signals was calculated and B-mode images were reconstructed. The texture was analysed in the axial direction by first- and second-order statistical methods. The accuracy and precision of the attenuation methods were assessed by using computer simulated RF signals and RF data obtained from a tissue-mimicking phantom. The phantom measurements were also used to test the performance of the methods to correct for the depth dependencies. The echograms of 163 persons, both volunteers and patients suffering from a diffuse liver disease (cirrhosis, hepatitis, haemochromatosis), were recorded. The mutual correlations between the estimated parameters were used to preselect parameters contributing independent information, and which can subsequently be used in a discriminant analysis to differentiate between the various diseased conditions.

Entities:  

Mesh:

Year:  1991        PMID: 1924541     DOI: 10.1088/0031-9155/36/8/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  In vivo ultrasonic attenuation slope estimates for detecting cervical ripening in rats: Preliminary results.

Authors:  Timothy A Bigelow; Barbara L McFarlin; William D O'Brien; Michael L Oelze
Journal:  J Acoust Soc Am       Date:  2008-03       Impact factor: 1.840

2.  Simultaneous estimation of attenuation and structure parameters of aggregated red blood cells from backscatter measurements.

Authors:  Emilie Franceschini; François T H Yu; Guy Cloutier
Journal:  J Acoust Soc Am       Date:  2008-04       Impact factor: 1.840

3.  Usefulness of textural analysis as a tool for noninvasive liver fibrosis staging.

Authors:  Cristian Vicas; Monica Lupsor; Radu Badea; Sergiu Nedevschi
Journal:  J Med Ultrason (2001)       Date:  2011-05-27       Impact factor: 1.314

4.  Ultrasound characterization of red blood cell aggregation with intervening attenuating tissue-mimicking phantoms.

Authors:  Emilie Franceschini; François T H Yu; François Destrempes; Guy Cloutier
Journal:  J Acoust Soc Am       Date:  2010-02       Impact factor: 1.840

5.  Ultrasonic attenuation estimation of the pregnant cervix: a preliminary report.

Authors:  B L McFarlin; T A Bigelow; Y Laybed; W D O'Brien; M L Oelze; J S Abramowicz
Journal:  Ultrasound Obstet Gynecol       Date:  2010-08       Impact factor: 7.299

6.  Studies on tissue characterization by texture analysis with co-occurrence matrix method using ultrasonography and CT imaging.

Authors:  Yi Wang; Kouichi Itoh; Nobuyuki Taniguchi; Hisao Toei; Fukiko Kawai; Michiru Nakamura; Kiyoka Omoto; Kyoko Yokota; Tomoko Ono
Journal:  J Med Ultrason (2001)       Date:  2002-12       Impact factor: 1.314

7.  Adaptive attenuation correction during H-scan ultrasound imaging using K-means clustering.

Authors:  Haowei Tai; Mawia Khairalseed; Kenneth Hoyt
Journal:  Ultrasonics       Date:  2019-08-23       Impact factor: 2.890

8.  Backscattering measurement from a single microdroplet.

Authors:  Jungwoo Lee; Jin Ho Chang; Jong Seob Jeong; Changyang Lee; Shia-Yen Teh; Abraham Lee; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-04       Impact factor: 2.725

9.  Feasibility of A-mode ultrasound attenuation as a monitoring method of local hyperthermia treatment.

Authors:  Noraida Abd Manaf; Maizatul Nadwa Che Aziz; Dzulfadhli Saffuan Ridzuan; Maheza Irna Mohamad Salim; Asnida Abd Wahab; Khin Wee Lai; Yan Chai Hum
Journal:  Med Biol Eng Comput       Date:  2016-04-02       Impact factor: 2.602

Review 10.  Review of Quantitative Ultrasound: Envelope Statistics and Backscatter Coefficient Imaging and Contributions to Diagnostic Ultrasound.

Authors:  Michael L Oelze; Jonathan Mamou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-01-08       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.