Literature DB >> 20122425

Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes.

Janalt Damstra1, Zacharias Fourie, James J R Huddleston Slater, Yijin Ren.   

Abstract

INTRODUCTION: The aims of this study were to determine the linear accuracy of 3-dimensional surface models derived from a commercially available cone-beam computed tomography (CBCT) dental imaging system and volumetric rendering software and to investigate the influence of voxel resolution on the linear accuracy of CBCT surface models.
METHODS: Glass sphere markers were fixed on 10 dry mandibles. The mandibles were scanned with 0.40 and 0.25 voxel size resolutions in 3 sessions. Anatomic truth was established with 6 direct digital caliper measurements. The surface models were rendered by a volumetric rendering program, and the CBCT measurements were established as the mean of the 3 measurements.
RESULTS: The intraclass correlation coefficients between the physical measurements and the measurements of the CBCT images of 0.40 and 0.25 voxels were all more than 0.99. All CBCT measurements were accurate. There was no difference between the accuracy of the measurements between the 0.40 and 0.25 voxel size groups. The smallest detectable differences of the CBCT measurements were minimal, confirming the accuracy of the CBCT measurement procedure.
CONCLUSIONS: The measurements on 3-dimensional surface models of 0.25 and 0.40 voxel size data sets made with the 3D eXam CBCT scanner (KaVo Dental GmbH, Bismarckring, Germany) and SimPlant Ortho Pro software (version 2.00, Materialise Dental, Leuven, Belgium) are accurate compared with direct caliper measurements. An increased voxel resolution did not result in greater accuracy of the surface model measurments. Copyright 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Mesh:

Year:  2010        PMID: 20122425     DOI: 10.1016/j.ajodo.2009.06.016

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  37 in total

1.  Accuracy of CBCT measurements of a human skull.

Authors:  Kivanç Kamburoğlu; Eray Kolsuz; Hakan Kurt; Cenk Kiliç; Tuncer Özen; Candan Semra Paksoy
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

2.  Accuracy of anatomical landmark identification using different CBCT- and MSCT-based 3D images: an in vitro study.

Authors:  Jürgen Medelnik; Klaus Hertrich; Stefanie Steinhäuser-Andresen; Ursula Hirschfelder; Elisabeth Hofmann
Journal:  J Orofac Orthop       Date:  2011-09-08       Impact factor: 1.938

3.  Comparison of the influence of FOV sizes and different voxel resolutions for the assessment of periodontal defects.

Authors:  M E Kolsuz; N Bagis; K Orhan; H Avsever; K Ö Demiralp
Journal:  Dentomaxillofac Radiol       Date:  2015-04-22       Impact factor: 2.419

4.  Analysis of linear measurements on 3D surface models using CBCT data segmentation obtained by automatic standard pre-set thresholds in two segmentation software programs: an in vitro study.

Authors:  Marcelo Lupion Poleti; Thais Maria Freire Fernandes; Otávio Pagin; Marcela Rodrigues Moretti; Izabel Regina Fischer Rubira-Bullen
Journal:  Clin Oral Investig       Date:  2015-05-13       Impact factor: 3.573

5.  Artifacts in orthodontic bracket systems in cone-beam computed tomography and multislice computed tomography.

Authors:  V Hirschinger; S Hanke; U Hirschfelder; E Hofmann
Journal:  J Orofac Orthop       Date:  2015-03       Impact factor: 1.938

Review 6.  Impact of voxel size variation on CBCT-based diagnostic outcome in dentistry: a systematic review.

Authors:  Rubens Spin-Neto; Erik Gotfredsen; Ann Wenzel
Journal:  J Digit Imaging       Date:  2013-08       Impact factor: 4.056

7.  Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography.

Authors:  Dongyun Wang; Andreas Künzel; Vladimir Golubovic; Ilya Mihatovic; Gordon John; Zhuofan Chen; Jürgen Becker; Frank Schwarz
Journal:  Clin Oral Investig       Date:  2012-10-12       Impact factor: 3.573

8.  Comparative study of image quality and radiation dose of cone beam and low-dose multislice computed tomography--an in-vitro investigation.

Authors:  Elisabeth Hofmann; Matthias Schmid; Martin Sedlmair; Rosemarie Banckwitz; Ursula Hirschfelder; Michael Lell
Journal:  Clin Oral Investig       Date:  2013-03-05       Impact factor: 3.573

9.  Integration of a maxillary model into facial surface stereophotogrammetry.

Authors:  T E Bechtold; T G Göz; E Schaupp; B Koos; A Godt; S Reinert; M Berneburg
Journal:  J Orofac Orthop       Date:  2012-04       Impact factor: 1.938

10.  Cone beam computed tomography and low-dose multislice computed tomography in orthodontics and dentistry: a comparative evaluation on image quality and radiation exposure.

Authors:  E Hofmann; M Schmid; M Lell; U Hirschfelder
Journal:  J Orofac Orthop       Date:  2014-08-28       Impact factor: 1.938

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.