Effects of cold sphere walls in PET phantom measurements on the volume reproducing threshold.

F Hofheinz1, S Dittrich, C Pötzsch, J van den Hoff.   

Abstract

We studied quantitatively the effects of the discontinuity introduced in an otherwise homogeneous background by the cold walls of the standard spherical glass inserts commonly used in phantom measurements for calibration of threshold-based approaches to volumetric evaluation of PET investigations. We concentrated especially on the question of threshold-based volume determination. We computed analytically the convolution of an isotropic Gaussian point-spread function with the insert geometry (hot sphere + cold wall + warm background) and derived the theoretical background dependence of the volume reproducing threshold. This analysis shows a clear wall-related reduction of the optimal threshold with increasing background. The predictions of our theoretical analysis were verified in phantom measurements at background fractions between 0 and 0.29. Defining the background-corrected relative threshold [formula: see text] (T(abs): absolute volume reproducing threshold, A: measured activity at centre, B: background), we find that for a wall-less sphere T is independent of the background level. In the presence of cold walls, T drops (for not too small spheres, where recovery at the centre approaches 100%) from about 43% at B/A = 0 to about 25% at B/A = 0.5. Applying these thresholds to wall-less spheres leads to sizeable overestimates of the true volumes (43% at B/A = 0.5 for a sphere of 6 ml volume). We conclude that phantom measurements with standard sphere inserts for calibration of optimal thresholding algorithms introduce a systematic bias if performed at finite background levels. The observed background dependence is an artefact of the measurement procedure and does not reflect the conditions present in actual patient investigations.

Entities:  

Mesh:

Year:  2010        PMID: 20107246     DOI: 10.1088/0031-9155/55/4/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  27 in total

Review 1.  A review on segmentation of positron emission tomography images.

Authors:  Brent Foster; Ulas Bagci; Awais Mansoor; Ziyue Xu; Daniel J Mollura
Journal:  Comput Biol Med       Date:  2014-04-28       Impact factor: 4.589

2.  The impact of iterative reconstruction protocol, signal-to-background ratio and background activity on measurement of PET spatial resolution.

Authors:  Sahar Rezaei; Pardis Ghafarian; Mehrdad Bakhshayesh-Karam; Carlos F Uribe; Arman Rahmim; Saeed Sarkar; Mohammad Reza Ay
Journal:  Jpn J Radiol       Date:  2020-01-01       Impact factor: 2.374

3.  A fillable micro-hollow sphere lesion detection phantom using superposition.

Authors:  Frank P Difilippo; Sven L Gallo; Ryan S Klatte; Sagar Patel
Journal:  Phys Med Biol       Date:  2010-08-24       Impact factor: 3.609

4.  Pre-treatment partial-volume-corrected TLG is the best predictor of overall survival in patients with relapsing/refractory non-hodgkin lymphoma following radioimmunotherapy.

Authors:  Raheleh Taghvaei; Mahdi Zirakchian Zadeh; Reza Sirous; Sara Pourhassan Shamchi; William Y Raynor; Siavash Mehdizadeh Seraj; Mateen Moghbel; Shiyu Wang; Thomas J Werner; Hongming Zhuang; Abass Alavi
Journal:  Am J Nucl Med Mol Imaging       Date:  2018-12-20

5.  FDG PET/CT in Crohn's disease: correlation of quantitative FDG PET/CT parameters with clinical and endoscopic surrogate markers of disease activity.

Authors:  Babak Saboury; Ali Salavati; Alex Brothers; Sandip Basu; Thomas C Kwee; Marnix G E H Lam; Roland Hustinx; Edouard Louis; Drew A Torigian; Abass Alavi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-20       Impact factor: 9.236

6.  Impact of [¹⁸F]FDG PET imaging parameters on automatic tumour delineation: need for improved tumour delineation methodology.

Authors:  Patsuree Cheebsumon; Maqsood Yaqub; Floris H P van Velden; Otto S Hoekstra; Adriaan A Lammertsma; Ronald Boellaard
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-08-20       Impact factor: 9.236

7.  A Study of the Feasibility of FDG-PET/CT to Systematically Detect and Quantify Differential Metabolic Effects of Chronic Tobacco Use in Organs of the Whole Body-A Prospective Pilot Study.

Authors:  Drew A Torigian; Judith Green-McKenzie; Xianling Liu; Frances S Shofer; Thomas Werner; Catherine E Smith; Andrew A Strasser; Mateen C Moghbel; Ami H Parekh; Grace Choi; Marcus D Goncalves; Natalie Spaccarelli; Saied Gholami; Prithvi S Kumar; Yubing Tong; Jayaram K Udupa; Clementina Mesaros; Abass Alavi
Journal:  Acad Radiol       Date:  2016-10-18       Impact factor: 3.173

8.  The first MICCAI challenge on PET tumor segmentation.

Authors:  Mathieu Hatt; Baptiste Laurent; Anouar Ouahabi; Hadi Fayad; Shan Tan; Laquan Li; Wei Lu; Vincent Jaouen; Clovis Tauber; Jakub Czakon; Filip Drapejkowski; Witold Dyrka; Sorina Camarasu-Pop; Frédéric Cervenansky; Pascal Girard; Tristan Glatard; Michael Kain; Yao Yao; Christian Barillot; Assen Kirov; Dimitris Visvikis
Journal:  Med Image Anal       Date:  2017-12-09       Impact factor: 8.545

9.  Combining multiple FDG-PET radiotherapy target segmentation methods to reduce the effect of variable performance of individual segmentation methods.

Authors:  Ross J McGurk; James Bowsher; John A Lee; Shiva K Das
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

10.  PET-based delineation of tumour volumes in lung cancer: comparison with pathological findings.

Authors:  Andrea Schaefer; Yoo Jin Kim; Stephanie Kremp; Sebastian Mai; Jochen Fleckenstein; Hendrik Bohnenberger; Hans-Joachim Schäfers; Jan-Martin Kuhnigk; Rainer M Bohle; Christian Rübe; Carl-Martin Kirsch; Aleksandar Grgic
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-04-30       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.