Literature DB >> 31894449

The impact of iterative reconstruction protocol, signal-to-background ratio and background activity on measurement of PET spatial resolution.

Sahar Rezaei1,2, Pardis Ghafarian3,4, Mehrdad Bakhshayesh-Karam5,6, Carlos F Uribe7, Arman Rahmim8,9, Saeed Sarkar2, Mohammad Reza Ay1,2.   

Abstract

OBJECTIVES: The present study aims to assess the impact of acquisition time, different iterative reconstruction protocols as well as image context (including contrast levels and background activities) on the measured spatial resolution in PET images.
METHODS: Discovery 690 PET/CT scanner was used to quantify spatial resolutions in terms of full width half maximum (FWHM) as derived (i) directly from capillary tubes embedded in air and (ii) indirectly from 10 mm-diameter sphere of the NEMA phantom. Different signal-to-background ratios (SBRs), background activity levels and acquisition times were applied. The emission data were reconstructed using iterative reconstruction protocols. Various combinations of iterations and subsets (it × sub) were evaluated.
RESULTS: For capillary tubes, improved FWHM values were obtained for higher it × sub, with improved performance for PSF algorithms relative to non-PSF algorithms. For the NEMA phantom, by increasing acquisition times from 1 to 5 min, intrinsic FWHM for reconstructions with it × sub 32 (54) was improved by 15.3% (13.2%), 15.1% (13.8%), 14.5% (12.8%) and 13.7% (12.7%) for OSEM, OSEM + PSF, OSEM + TOF and OSEM + PSF + TOF, respectively. Furthermore, for all reconstruction protocols, the FWHM improved with more impact for higher it × sub.
CONCLUSION: Our results indicate that PET spatial resolution is greatly affected by SBR, background activity and the choice of the reconstruction protocols.

Entities:  

Keywords:  FWHM; Iterative reconstruction; PSF; Positron emission tomography; Spatial resolution; TOF

Mesh:

Year:  2020        PMID: 31894449     DOI: 10.1007/s11604-019-00914-3

Source DB:  PubMed          Journal:  Jpn J Radiol        ISSN: 1867-1071            Impact factor:   2.374


  43 in total

1.  Impact of Image Reconstruction Settings on Texture Features in 18F-FDG PET.

Authors:  Jianhua Yan; Jason Lim Chu-Shern; Hoi Yin Loi; Lih Kin Khor; Arvind K Sinha; Swee Tian Quek; Ivan W K Tham; David Townsend
Journal:  J Nucl Med       Date:  2015-07-30       Impact factor: 10.057

Review 2.  Partial-volume effect in PET tumor imaging.

Authors:  Marine Soret; Stephen L Bacharach; Irène Buvat
Journal:  J Nucl Med       Date:  2007-05-15       Impact factor: 10.057

3.  A method for on-site measurements of the effective spatial resolution in PET image volumes reconstructed with OSEM and Gaussian post-filters.

Authors:  Arne Skretting
Journal:  Radiat Prot Dosimetry       Date:  2010-02-17       Impact factor: 0.972

4.  Impact of [¹⁸F]FDG PET imaging parameters on automatic tumour delineation: need for improved tumour delineation methodology.

Authors:  Patsuree Cheebsumon; Maqsood Yaqub; Floris H P van Velden; Otto S Hoekstra; Adriaan A Lammertsma; Ronald Boellaard
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-08-20       Impact factor: 9.236

5.  Quantification and reduction of respiratory induced artifacts in positron emission tomography/computed tomography using the time-of-flight technique.

Authors:  Roya Sharifpour; Pardis Ghafarian; Arman Rahmim; Mohammad R Ay
Journal:  Nucl Med Commun       Date:  2017-11       Impact factor: 1.690

6.  Impact of time-of-flight and point-spread-function in SUV quantification for oncological PET.

Authors:  Elena Prieto; Inés Domínguez-Prado; María José García-Velloso; Iván Peñuelas; José Ángel Richter; Josep Maria Martí-Climent
Journal:  Clin Nucl Med       Date:  2013-02       Impact factor: 7.794

7.  Clinical impact of time-of-flight and point response modeling in PET reconstructions: a lesion detection study.

Authors:  Joshua Schaefferkoetter; Michael Casey; David Townsend; Georges El Fakhri
Journal:  Phys Med Biol       Date:  2013-02-13       Impact factor: 3.609

8.  Simultaneous measurement of noise and spatial resolution in PET phantom images.

Authors:  Martin A Lodge; Arman Rahmim; Richard L Wahl
Journal:  Phys Med Biol       Date:  2010-01-28       Impact factor: 3.609

9.  Improvement in PET/CT image quality in overweight patients with PSF and TOF.

Authors:  Takafumi Taniguchi; Go Akamatsu; Yukiko Kasahara; Katsuhiko Mitsumoto; Shingo Baba; Yuji Tsutsui; Kazuhiko Himuro; Shohei Mikasa; Daisuke Kidera; Masayuki Sasaki
Journal:  Ann Nucl Med       Date:  2014-09-26       Impact factor: 2.668

10.  The influence of different signal-to-background ratios on spatial resolution and F18-FDG-PET quantification using point spread function and time-of-flight reconstruction.

Authors:  Julian Mm Rogasch; Frank Hofheinz; Alexandr Lougovski; Christian Furth; Juri Ruf; Oliver S Großer; Konrad Mohnike; Peter Hass; Mathias Walke; Holger Amthauer; Ingo G Steffen
Journal:  EJNMMI Phys       Date:  2014-09-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.