Literature DB >> 20105090

Breast tomosynthesis: Accuracy of tumor measurement compared with digital mammography and ultrasonography.

Daniel Förnvik1, Sophia Zackrisson, Otto Ljungberg, Tony Svahn, Pontus Timberg, Anders Tingberg, Ingvar Andersson.   

Abstract

BACKGROUND: Mammographic tumor size measurement can be difficult because breast structures are superimposed onto a two-dimensional (2D) plane, potentially obscuring the tumor outline. Breast tomosynthesis (BT) is a 3D X-ray imaging technique in which low-dose images are acquired over a limited angular range at a total dose comparable to digital mammography (DM). These low-dose images are used to mathematically reconstruct a 3D image volume of the breast, thus reducing the problem of superimposed tissue.
PURPOSE: To investigate whether breast cancer size can be more accurately assessed with breast tomosynthesis than with digital mammography and ultrasonography (US), by reducing the disturbance effect of the projected anatomy.
MATERIAL AND METHODS: A prototype BT system was used. The main inclusion criterion for BT examination was subtle but suspicious findings of breast cancer on 2D mammography. Sixty-two women with 73 breast cancers were included. BT, DM, and US sizes were measured independently by experienced radiologists without knowledge of the pathology results, which were used as reference.
RESULTS: The tumor outline could be determined in significantly more cases with BT (63) and US (60) than DM (49). BT and US size correlated well with pathology (R=0.86 and R=0.85, respectively), and significantly better than DM size (R=0.71). Accordingly, staging was significantly more accurate with BT than with DM.
CONCLUSION: The study indicates that BT is superior to DM in the assessment of breast tumor size and stage.

Entities:  

Mesh:

Year:  2010        PMID: 20105090     DOI: 10.3109/02841850903524447

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  37 in total

Review 1.  [Digital breast tomosynthesis : technical principles, current clinical relevance and future perspectives].

Authors:  K Hellerhoff
Journal:  Radiologe       Date:  2010-11       Impact factor: 0.635

2.  Digital Breast Tomosynthesis: State of the Art.

Authors:  Srinivasan Vedantham; Andrew Karellas; Gopal R Vijayaraghavan; Daniel B Kopans
Journal:  Radiology       Date:  2015-12       Impact factor: 11.105

3.  Diagnostic accuracy of digital breast tomosynthesis versus digital mammography for benign and malignant lesions in breasts: a meta-analysis.

Authors:  Junqiang Lei; Pin Yang; Li Zhang; Yinzhong Wang; Kehu Yang
Journal:  Eur Radiol       Date:  2014-03       Impact factor: 5.315

4.  [Digital breast tomosynthesis].

Authors:  H Preibsch; K C Siegmann-Luz
Journal:  Radiologe       Date:  2015-01       Impact factor: 0.635

5.  Staging of breast cancer and the advanced applications of digital mammogram: what the physician needs to know?

Authors:  Maha H Helal; Sahar M Mansour; Mai Zaglol; Lamia A Salaleldin; Omniya M Nada; Marwa A Haggag
Journal:  Br J Radiol       Date:  2017-02-22       Impact factor: 3.039

6.  Digital breast tomosynthesis versus supplemental diagnostic mammographic views for evaluation of noncalcified breast lesions.

Authors:  Margarita L Zuley; Andriy I Bandos; Marie A Ganott; Jules H Sumkin; Amy E Kelly; Victor J Catullo; Grace Y Rathfon; Amy H Lu; David Gur
Journal:  Radiology       Date:  2012-11-09       Impact factor: 11.105

7.  Digital breast tomosynthesis versus mammography and breast ultrasound: a multireader performance study.

Authors:  Fabienne Thibault; Clarisse Dromain; Catherine Breucq; Corinne S Balleyguier; Caroline Malhaire; Luc Steyaert; Anne Tardivon; Enrica Baldan; Harir Drevon
Journal:  Eur Radiol       Date:  2013-05-15       Impact factor: 5.315

8.  Accuracy of tumour size assessment in the preoperative staging of breast cancer: comparison of digital mammography, tomosynthesis, ultrasound and MRI.

Authors:  Andrea Luparia; Giovanna Mariscotti; Manuela Durando; Stefano Ciatto; Davide Bosco; Pier Paolo Campanino; Isabella Castellano; Anna Sapino; Giovanni Gandini
Journal:  Radiol Med       Date:  2013-06-25       Impact factor: 3.469

9.  [Future of mammography-based imaging].

Authors:  R Schulz-Wendtland; T Wittenberg; T Michel; A Hartmann; M W Beckmann; C Rauh; S M Jud; B Brehm; M Meier-Meitinger; G Anton; M Uder; P A Fasching
Journal:  Radiologe       Date:  2014-03       Impact factor: 0.635

10.  A model study of 3-dimensional localization of breast tumors using piezoelectric fingers of different probe sizes.

Authors:  Xin Xu; Wei-Heng Shih; Wan Y Shih
Journal:  Rev Sci Instrum       Date:  2019-01       Impact factor: 1.523

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.