Literature DB >> 20103206

Patient-prosthesis mismatch in patients with aortic stenosis undergoing isolated aortic valve replacement does not affect survival.

Neil J Howell1, Bruce E Keogh, Daniel Ray, Robert S Bonser, Tim R Graham, Jorge Mascaro, Stephen J Rooney, Ian C Wilson, Domenico Pagano.   

Abstract

BACKGROUND: Data suggest that patient-prosthesis mismatch (PPM) adversely effects late survival after aortic valve replacement (AVR). This study examined the incidence and implications of PPM in patients undergoing isolated AVR.
METHODS: Prospectively collected data on patients undergoing isolated AVR for aortic stenosis between January 1, 1997 and December 31, 2007 were analyzed. The projected effective valve orifice area from in vivo data was indexed to body surface area (EOAi). PPM was defined as moderate for EOAi of < or = 0.85 cm(2)/m(2) and severe if < or = 0.6 cm(2)/m(2). The reference group comprised patients with EOAi > 0.85 cm(2)/m(2). The effect of PPM on postoperative survival was assessed by multivariate analysis.
RESULTS: Of 801 patients, PPM was severe in 48 (6.0%), moderate in 462 (57.8%), and nonexistent in 291 (36.4%). Mismatch was associated with increasing age and female gender, thus resulting in an increase in the EuroSCORE (reference group, 4.9 +/- 2.6; moderate PPM, 5.8 +/- 2.4; and severe PPM, 6.1+/-2.1; p < 0.001). PPM did not significantly increase hospital mortality. Four deaths occurred in the reference group (1.4%), 12 in the moderate PPM (2.6%), and none in the severe PPM group (p = 0.311). The 5-year survival estimates were 83% in reference, 86% in moderate PPM, and 89% in severe PPM (p = 0.25). By multivariate analysis, PPM was not an independent risk factor for reduced in-hospital or late survival.
CONCLUSIONS: Moderate PPM is common in patients undergoing AVR for aortic stenosis, but severe mismatch is rare. Patients with PPM have similar early and late postoperative survival rate. 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20103206     DOI: 10.1016/j.athoracsur.2009.07.037

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  17 in total

Review 1.  Prosthesis-patient mismatch: an update.

Authors:  Jean G Dumesnil; Philippe Pibarot
Journal:  Curr Cardiol Rep       Date:  2011-06       Impact factor: 2.931

Review 2.  Sex-Specific Considerations in Women with Aortic Stenosis and Outcomes After Transcatheter Aortic Valve Replacement.

Authors:  Christos G Mihos; Sheila L Klassen; Evin Yucel
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-06-19

3.  The impact of age on the postoperative response of the diastolic function and left ventricular mass regression after surgical or transcatheter aortic valve replacement for severe aortic stenosis.

Authors:  Teruya Nakamura; Koichi Toda; Toru Kuratani; Shigeru Miyagawa; Yasushi Yoshikawa; Satsuki Fukushima; Shunsuke Saito; Yoshiki Sawa
Journal:  Surg Today       Date:  2016-12-24       Impact factor: 2.549

4.  Patient prosthesis mismatch and its impact on left ventricular regression following aortic valve replacement in aortic stenosis patients.

Authors:  Abid Iqbal; Varghese Thomas Panicker; Jayakumar Karunakaran
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2018-08-28

Review 5.  Prosthesis-patient mismatch in aortic stenosis.

Authors:  Kentaro Honda; Yoshitaka Okamura
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-10-17

6.  Incidence and Impact of Patient-Prosthesis Mismatch in Isolated Aortic Valve Surgery.

Authors:  Selman Dumani; Ermal Likaj; Andi Kacani; Laureta Dibra; Elizana Petrela; Vera Beca; Ali Refatllari
Journal:  Open Access Maced J Med Sci       Date:  2015-10-15

7.  Impact of prosthesis-patient mismatch on early and late mortality after aortic valve replacement.

Authors:  Bart M Koene; Mohamed A Soliman Hamad; Wobbe Bouma; Massimo A Mariani; Kathinka C Peels; Jan-Melle van Dantzig; Albert H van Straten
Journal:  J Cardiothorac Surg       Date:  2013-04-17       Impact factor: 1.637

8.  Patient-prosthesis mismatch in patients with aortic valve replacement.

Authors:  Yuichiro Kaminishi; Yoshio Misawa; Junjiro Kobayashi; Hiroaki Konishi; Hiroaki Miyata; Noboru Motomura; Shin-ichi Takamoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-02-13

9.  Can postoperative mean transprosthetic pressure gradient predict survival after aortic valve replacement?

Authors:  Bart M Koene; Mohamed A Soliman Hamad; Wobbe Bouma; Massimo A Mariani; Kathinka C Peels; Jan-Melle van Dantzig; Albert H van Straten
Journal:  Clin Res Cardiol       Date:  2013-10-18       Impact factor: 5.460

10.  Mid-term outcomes of rapid deployment aortic prostheses in patients with small aortic annulus.

Authors:  José M Arribas-Leal; José Miguel Rivera-Caravaca; Ramón Aranda-Domene; José A Moreno-Moreno; Dolores Espinosa-Garcia; Antonio Jimenez-Aceituna; Joaquín Perez-Andreu; Rubén Taboada-Martin; Daniel R Saura-Espin; Sergio J Canovas-Lopez
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-10-29
View more