Literature DB >> 20092076

Clinical evaluation of the Terumo Capiox FX05 hollow fiber oxygenator with integrated arterial line filter.

Joseph Deptula1, Melinda Valleley, Kimberly Glogowski, John Detwiler, James Hammel, Kim Duncan.   

Abstract

Perfusion techniques and equipment in pediatric open heart surgery have continued to focus on decreasing prime volumes and lowering surface areas of the cardiopulmonary bypass circuit. While this has improved drastically over the last 20 years, greater demand is being placed on the perfusionist to reduce the deleterious effects of bypass without compromising safety or efficiency. Specifically, manufacturers of disposable perfusion equipment have focused on providing pediatric perfusionists with oxygenators that provide the smallest prime and surface area possible while attempting to maximize performance. Recently,Terumo Cardiovascular has introduced the Capiox FX05, a neonatal hollow fiber oxygenator that includes an integrated arterial line filter. The FX05 provides a blood flow range of 0.1-1.5 L/min and a low priming volume of 43 mL. Additionally, it is coated with X Coating, a biocompatible, hydrophilic polymer surface coating that reduces platelet adhesion and protein denaturation. The purpose of this study was to test the FX05 for gas transfer, blood path resistance, and blood handling characteristics in a standardized clinical setting. Heat exchange coefficients were also calculated during the cooling and warming period. Other data analyzed includes bypass circuit prime volumes and initial patient hematocrit along with the total operative homologous blood donor exposures. In summary, the FX05 offers good gas exchange capabilities and a low pressure drop during normal cardiopulmonary bypass parameters along with the safety of an integrated arterial line filter. Furthermore, the FX05 with integrated filter allows a reduction in overall bypass prime volume and surface area while promoting the reduction of homologous blood transfusions, optimizing hemostasis.

Entities:  

Mesh:

Year:  2009        PMID: 20092076      PMCID: PMC4813544     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  9 in total

1.  In vivo comparison study of FDA-approved surface-modifying additives and poly-2-methoxyethylacrylate circuit surfaces coatings during cardiopulmonary bypass.

Authors:  Angela Ask; David Holt; Lynette Smith
Journal:  J Extra Corpor Technol       Date:  2006-03

Review 2.  Risks of transfusion: outcome focus.

Authors:  Bruce D Spiess
Journal:  Transfusion       Date:  2004-12       Impact factor: 3.157

3.  Clinical evaluation of the Sorin Synthesis oxygenator with integrated arterial filter.

Authors:  Gerard J Myers; Ken Gardiner; Steve N Ditmore; Wilfred J Swyer; Chris Squires; David R Johnstone; Clarie V Power; Lance B Mitchell; Jan E Ditmore; Bill Cook
Journal:  J Extra Corpor Technol       Date:  2005-06

4.  Update on pediatric perfusion practice in North America: 2005 survey.

Authors:  Robert C Groom; Shane Froebe; Janine Martin; Michael J Manfra; John E Cormack; Catherine Morse; Andreas H Taenzer; Reed D Quinn
Journal:  J Extra Corpor Technol       Date:  2005-12

5.  Effect of hemofiltrated whole blood pump priming on hemodynamics and respiratory function after the arterial switch operation in neonates.

Authors:  M Nagashima; Y Imai; K Seo; M Terada; M Aoki; T Shinóka; M Koide
Journal:  Ann Thorac Surg       Date:  2000-12       Impact factor: 4.330

6.  Use of a low-prime circuit for bloodless heart transplantation in xenotransplant of 5-7 kilogram primates.

Authors:  D Gomez; V F Olshove; S Weinstein; J T Davis; R E Michler
Journal:  J Extra Corpor Technol       Date:  2000-09

7.  Autologous priming technique to reduce blood transfusion in pediatric cardiopulmonary bypass.

Authors:  Jacob Ostrowsky; Mark Henderson; Hani Hennein
Journal:  J Extra Corpor Technol       Date:  2006-06

8.  Effect of polymer coating (poly 2-methoxyethylacrylate) of the oxygenator on hemostatic markers during cardiopulmonary bypass in children.

Authors:  Michael J Eisses; Jeremy M Geiduschek; Christer Jonmarker; Gordon A Cohen; Wayne L Chandler
Journal:  J Cardiothorac Vasc Anesth       Date:  2006-07-26       Impact factor: 2.628

9.  180 ml and less: cardiopulmonary bypass techniques to minimize hemodilution for neonates and small infants.

Authors:  Kevin Charette; Yasutaka Hirata; Adam Bograd; Linda Mongero; Jonathan Chen; Jan Quaegebeur; Ralph Mosca
Journal:  Perfusion       Date:  2007-09       Impact factor: 1.972

  9 in total
  6 in total

1.  Effects of Purge-Flow Rate on Microbubble Capture in Radial Arterial-Line Filters.

Authors:  Daniel P Herbst
Journal:  J Extra Corpor Technol       Date:  2016-09

2.  Removal of Gross Air Embolization from Cardiopulmonary Bypass Circuits with Integrated Arterial Line Filters: A Comparison of Circuit Designs.

Authors:  James A Reagor; David W Holt
Journal:  J Extra Corpor Technol       Date:  2016-03

3.  Modification of sodium, glucose, potassium, and osmolarity in packed red blood cells and fresh frozen plasma using a desktop hemoconcentrator setup.

Authors:  Carrie Whittaker Striker; Stacia Woldorf; David Holt
Journal:  J Extra Corpor Technol       Date:  2012-06

4.  Stage 1 palliation for hypoplastic left heart syndrome without the use of allogeneic tissue, with reduced allogeneic blood product exposure: a case report.

Authors:  Joseph Deptula; James Hammel; Kari George; John Detwiler; Kimberly Glogowski; Melinda Valleley; Kim Duncan
Journal:  J Extra Corpor Technol       Date:  2011-12

5.  Randomized trial of the Terumo Capiox FX05 oxygenator with integral arterial filter versus Terumo Capiox Baby RX05 and Terumo Capiox AF02 arterial filter in infants undergoing cardiopulmonary bypass.

Authors:  Mark M Nuszkowski; Nina Deutsch; Richard A Jonas; David Zurakowski; Erin Montague; David W Holt
Journal:  J Extra Corpor Technol       Date:  2011-12

6.  Cryoprecipitate and platelet administration during modified ultrafiltration in children less than 10 kg undergoing cardiac surgery.

Authors:  Brian L Mejak; Richard J Ing; Craig McRobb; W Cory Ellis; D Scott Lawson; Mark D Twite; James Jaggers
Journal:  J Extra Corpor Technol       Date:  2013-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.