Clinical evaluation of the Sorin Synthesis oxygenator with integrated arterial filter.

Gerard J Myers1, Ken Gardiner, Steve N Ditmore, Wilfred J Swyer, Chris Squires, David R Johnstone, Clarie V Power, Lance B Mitchell, Jan E Ditmore, Bill Cook.   

Abstract

The use of arterial line filters has long been a standard of practice in the field of cardiopulmonary bypass. Sorin Biomedica has designed an adult hollow-fiber oxygenator that not only incorporates their Mimesys biomimicry coating technology but also has a 40-micron arterial filter as an integrated component of this unique membrane oxygenator. We did a prospective, randomized clinical trial of 54 Synthesis coated oxygenators and compared them with 54 uncoated Monolyth Pro oxygenators, the latter of which incorporated an external arterial line filter with a standard bypass loop There were few statistically significant differences found between the Synthesis group and the Monolyth group with regard to pressure differentials, hemodynamic resistance, and platelet drop. The Synthesis oxygenator did require less priming volume, but the amount was not significant. Platelet counts with the Phosphorylcholine coated Synthesis oxygenators, using crystalloid perfusates, was similar to our previously published data on platelet protection and Albumin perfusates. We conclude that the Sorin Synthesis oxygenator appears to have better flow characteristics than the Monolyth oxygenator, with the potential for lower priming volumes. The most clinically significant benefit comes from the elimination of the arterial filter bypass loop and the avoidance of inverting the arterial filter during priming.

Entities:  

Mesh:

Year:  2005        PMID: 16117460      PMCID: PMC4682537     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  8 in total

1.  Ex vivo testing of the Quart arterial line filter.

Authors:  X M Mueller; H T Tevaearai; D Jegger; M Augstburger; M Burki; L K von Segesser
Journal:  Perfusion       Date:  1999-11       Impact factor: 1.972

2.  Evaluation of Mimesys phosphorylcholine (PC)-coated oxygenators during cardiopulmonary bypass in adults.

Authors:  Gerard J Myers; David R Johnstone; Wilfred J Swyer; Scott McTeer; Sandy L Maxwell; Chris Squires; Steve N Ditmore; Clarie V Power; Lance B Mitchell; Jan E Ditmore; Larry D Aniuk; Greg M Hirsch; Karen J Buth
Journal:  J Extra Corpor Technol       Date:  2003-03

3.  Ex vivo evaluation of a new neonatal/infant oxygenator: comparison of the Terumo CAPIOX Baby RX with Dideco Lilliput 1 and Polystan Safe Micro in the piglet model.

Authors:  J Dubois; L Jamaer; U Mees; J- L Pauwels; F Briers; J Lehaen; M Hendrikx
Journal:  Perfusion       Date:  2004       Impact factor: 1.972

4.  Clinical evaluation of nine hollow-fibre membrane oxygenators.

Authors:  P A Segers; J F Heida; I de Vries; C Maas; A J Boogaart; S Eilander
Journal:  Perfusion       Date:  2001-03       Impact factor: 1.972

5.  A multicenter investigation into the occurrence of high-pressure excursions.

Authors:  Gerard J Myers; Patrick R Weighell; Brian J McCloskey; Alison M Holt; Scott McTeer; Sandy L Maxwell
Journal:  J Extra Corpor Technol       Date:  2003-06

6.  Biomembranes as models for polymer surfaces. IV. ESCA analyses of a phosphorylcholine surface covalently bound to hydroxylated substrates.

Authors:  J A Hayward; A A Durrani; Y Lu; C R Clayton; D Chapman
Journal:  Biomaterials       Date:  1986-07       Impact factor: 12.479

7.  Arterial line filtration protects brain microcirculation during cardiopulmonary bypass in the pig.

Authors:  J Waaben; H R Sørensen; U L Andersen; K Gefke; J Lund; S Aggestrup; B Husum; H Laursen; A Gjedde
Journal:  J Thorac Cardiovasc Surg       Date:  1994-04       Impact factor: 5.209

8.  Elimination of microbubbles from the extracorporeal circuit: dynamic bubble trap versus arterial filter.

Authors:  S Martens; M Dietrich; R Pietrzyk; K Graubitz; H Keller; A Moritz
Journal:  Int J Artif Organs       Date:  2004-01       Impact factor: 1.595

  8 in total
  5 in total

1.  Goal-Directed Perfusion Methodology for Determining Oxygenator Performance during Clinical Cardiopulmonary Bypass.

Authors:  Alfred H Stammers; Randi Miller; Stephen G Francis; Laszlo Fuzesi; Anthony Nostro; Eric Tesdahl
Journal:  J Extra Corpor Technol       Date:  2017-06

2.  Effects of Purge-Flow Rate on Microbubble Capture in Radial Arterial-Line Filters.

Authors:  Daniel P Herbst
Journal:  J Extra Corpor Technol       Date:  2016-09

3.  Arterial filter bypass loop: what occurs in this area during cardiopulmonary bypass and are there potential patient implications.

Authors:  Justin L Hawkins; Gerard J Myers; Jean-Francois Légaré; Wilfred Swyer
Journal:  J Extra Corpor Technol       Date:  2010-03

4.  Clinical evaluation of the Terumo Capiox FX05 hollow fiber oxygenator with integrated arterial line filter.

Authors:  Joseph Deptula; Melinda Valleley; Kimberly Glogowski; John Detwiler; James Hammel; Kim Duncan
Journal:  J Extra Corpor Technol       Date:  2009-12

5.  Comparison of new technology integrated and nonintegrated arterial filters used in cardiopulmonary bypass surgery: a randomized, prospective, and single blind study.

Authors:  Özgür Gürsu; Selim Isbir; Koray Ak; Fethullah Gerin; Sinan Arsan
Journal:  Biomed Res Int       Date:  2013-11-11       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.