Removal of Gross Air Embolization from Cardiopulmonary Bypass Circuits with Integrated Arterial Line Filters: A Comparison of Circuit Designs.

James A Reagor1, David W Holt1.   

Abstract

Advances in technology, the desire to minimize blood product transfusions, and concerns relating to inflammatory mediators have lead many practitioners and manufacturers to minimize cardiopulmonary bypass (CBP) circuit designs. The oxygenator and arterial line filter (ALF) have been integrated into one device as a method of attaining a reduction in prime volume and surface area. The instructions for use of a currently available oxygenator with integrated ALF recommends incorporating a recirculation line distal to the oxygenator. However, according to an unscientific survey, 70% of respondents utilize CPB circuits incorporating integrated ALFs without a path of recirculation distal to the oxygenator outlet. Considering this circuit design, the ability to quickly remove a gross air bolus in the blood path distal to the oxygenator may be compromised. This in vitro study was designed to determine if the time required to remove a gross air bolus from a CPB circuit without a path of recirculation distal to the oxygenator will be significantly longer than that of a circuit with a path of recirculation distal to the oxygenator. A significant difference was found in the mean time required to remove a gross air bolus between the circuit designs (p = .0003). Additionally, There was found to be a statistically significant difference in the mean time required to remove a gross air bolus between Trial 1 and Trials 4 (p = .015) and 5 (p =.014) irrespective of the circuit design. Under the parameters of this study, a recirculation line distal to an oxygenator with an integrated ALF significantly decreases the time it takes to remove an air bolus from the CPB circuit and may be safer for clinical use than the same circuit without a recirculation line.

Entities:  

Keywords:  cardiopulmonary bypass; gas embolism; integrated arterial filter; practice; safety

Mesh:

Year:  2016        PMID: 27134304      PMCID: PMC4850218     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  13 in total

1.  Departmental use of perfusion crisis management drills: 2002 survey results.

Authors:  Richard Ginther; Roy Fillingham; Bruce Searles; Edward Darling
Journal:  Perfusion       Date:  2003-09       Impact factor: 1.972

2.  A survey on air bubble detector placement in the CPB circuit: a 2011 cross-sectional analysis of the practice of Certified Clinical Perfusionists.

Authors:  T Kelting; B Searles; E Darling
Journal:  Perfusion       Date:  2012-07       Impact factor: 1.972

Review 3.  Mini extracorporeal circuit cardiopulmonary bypass system: a review.

Authors:  Nathan Curtis; Hunaid A Vohra; Sunil K Ohri
Journal:  Perfusion       Date:  2010-05       Impact factor: 1.972

4.  Beneficial effects of using a minimal extracorporeal circulation system during coronary artery bypass grafting.

Authors:  Y Liu; L Tao; X Wang; H Cui; X Chen; B Ji
Journal:  Perfusion       Date:  2011-10-10       Impact factor: 1.972

5.  Mini-cardiopulmonary bypass impact on blood conservation strategy in coronary artery bypass grafting.

Authors:  Mohamed Abdel Aal; Nezar ElNahal; Bakir Moustafa Bakir; Mohamed Fouda
Journal:  Interact Cardiovasc Thorac Surg       Date:  2011-01-20

6.  Oxygenator change-out times: the value of a written protocol and simulation exercises.

Authors:  Edward Darling; Bruce Searles
Journal:  Perfusion       Date:  2010-04-21       Impact factor: 1.972

7.  Clinical evaluation of the Terumo Capiox FX05 hollow fiber oxygenator with integrated arterial line filter.

Authors:  Joseph Deptula; Melinda Valleley; Kimberly Glogowski; John Detwiler; James Hammel; Kim Duncan
Journal:  J Extra Corpor Technol       Date:  2009-12

8.  Clinical gaseous microemboli assessment of an oxygenator with integral arterial filter in the pediatric population.

Authors:  Thomas J Preston; Daniel Gomez; Vincent F Olshove; Alistair Phillips; Mark Galantowicz
Journal:  J Extra Corpor Technol       Date:  2009-12

9.  Report from AmSECT's International Consortium for Evidence-Based Perfusion: American Society of Extracorporeal Technology Standards and Guidelines for Perfusion Practice: 2013.

Authors:  Robert A Baker; Shahna L Bronson; Timothy A Dickinson; David C Fitzgerald; Donald S Likosky; Nicholas B Mellas; Kenneth G Shann
Journal:  J Extra Corpor Technol       Date:  2013-09

Review 10.  The inflammatory response to miniaturised extracorporeal circulation: a review of the literature.

Authors:  Hunaid A Vohra; Robert Whistance; Amit Modi; Sunil K Ohri
Journal:  Mediators Inflamm       Date:  2010-01-13       Impact factor: 4.711

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.