Literature DB >> 16524149

Update on pediatric perfusion practice in North America: 2005 survey.

Robert C Groom1, Shane Froebe, Janine Martin, Michael J Manfra, John E Cormack, Catherine Morse, Andreas H Taenzer, Reed D Quinn.   

Abstract

The devices and techniques used for pediatric cardiopulmonary bypass (CPB) undergo continuous change. New techniques and clinical comparisons of devices are frequently reported in the literature; however, information about the extent to which these techniques and devices are adopted into clinical practice at pediatric heart centers are not well described. We conducted a mail survey of North American pediatric cardiac surgery centers to gain perspective on the extent to which various devices and techniques were used for CPB along with program demographic data. In January 2005, surveys were mailed to 180 North American open heart centers. The survey was nearly identical in format and content to three earlier surveys completed in 1989, 1994, and 1999, with the exception that new questions were added to address new techniques and devices that have emerged over the years. Responses were received from 76 hospitals, for an overall response rate of 42%. Of the responding centers, 53 were performing pediatric open heart surgery and 23 were not. Twenty centers performed only pediatric open heart surgery, and 33 performed both pediatric and adult open heart surgery. The mean pediatric annual caseload of responding centers was 195 procedures/yr (range, 20-650 procedures/yr; median, 154 procedures/yr). A total of 9943 pediatric open heart procedures were performed at responding centers in 2004. Most of the centers surveyed reported use of an open venous reservoir system (88%), use of roller pumps (90%), and use of arterial line filtration (98%). Most centers used circuits that have surface treatments with heparin or some other surface-modifying agent (74%). There has been an increase in the use of all types of safety devices. Modified ultrafiltration is used at 75% of the centers surveyed. Centers reported an increase in the availability of all types of cardiac support devices including extracorporeal membrane oxygenation for postcardiotomy cardiac support (90%). This survey provides an overview of clinical practice in 2004. The series of surveys document the historical progression of clinical practice over the past 16 years. Practice surveys may also be useful for identifying gaps between evidence-based knowledge and clinical practice. These surveys document the diffusion of innovation related to CPB during the past 16 years and areas of variation in practice that need further study.

Entities:  

Mesh:

Year:  2005        PMID: 16524149      PMCID: PMC4680823     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  22 in total

1.  Factors affecting perfusionists' decisions on equipment utilization: results of a United States survey.

Authors:  A H Stammers; B L Mejak; E D Rauch; S N Vang; T W Viessman
Journal:  J Extra Corpor Technol       Date:  2000-03

2.  Superior biocompatibility of heparin-bonded circuits in pediatric cardiopulmonary bypass.

Authors:  T Ozawa; K Yoshihara; N Koyama; S Yamazaki; Y Takanashi
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  1999-12

3.  Cardiopulmonary bypass: Evidence or experience based?

Authors:  Claus Bartels; Anja Gerdes; Jörg Babin-Ebell; Friedhelm Beyersdorf; Udo Boeken; Torsten Doenst; Peter Feindt; Michael Heiermann; Christian Schlensak; Hans-Hinrich Sievers
Journal:  J Thorac Cardiovasc Surg       Date:  2002-07       Impact factor: 5.209

4.  Current paediatric perfusion practice in North America.

Authors:  A G Hill; R C Groom; B F Akl; E A Lefrak; M Kurusz
Journal:  Perfusion       Date:  1993-01       Impact factor: 1.972

5.  Blood gas management and degree of cooling: effects on cerebral metabolism before and after circulatory arrest.

Authors:  L A Skaryak; P J Chai; F H Kern; W J Greeley; R M Ungerleider
Journal:  J Thorac Cardiovasc Surg       Date:  1995-12       Impact factor: 5.209

6.  Oxygenation strategy and neurologic damage after deep hypothermic circulatory arrest. II. hypoxic versus free radical injury.

Authors:  G Nollert; M Nagashima; J Bucerius; T Shin'oka; H G Lidov; A du Plessis; R A Jonas
Journal:  J Thorac Cardiovasc Surg       Date:  1999-06       Impact factor: 5.209

7.  Quantitative evaluation of heparin-coated versus non-heparin-coated bypass circuits during cardiopulmonary bypass.

Authors:  A H Stammers; K A Christensen; J Lynch; D P Zavadil; J J Deptula; R T Sydzyik
Journal:  J Extra Corpor Technol       Date:  1999-09

8.  Perioperative effects of alpha-stat versus pH-stat strategies for deep hypothermic cardiopulmonary bypass in infants.

Authors:  A J du Plessis; R A Jonas; D Wypij; P R Hickey; J Riviello; D L Wessel; S J Roth; F A Burrows; G Walter; D M Farrell; A Z Walsh; C A Plumb; P del Nido; R P Burke; A R Castaneda; J E Mayer; J W Newburger
Journal:  J Thorac Cardiovasc Surg       Date:  1997-12       Impact factor: 5.209

9.  Hyperoxia for management of acid-base status during deep hypothermia with circulatory arrest.

Authors:  J M Pearl; D W Thomas; G Grist; J Y Duffy; P B Manning
Journal:  Ann Thorac Surg       Date:  2000-09       Impact factor: 4.330

10.  Influence of two different perfusion systems on inflammatory response in pediatric heart surgery.

Authors:  Eva Jensen; Svenerik Andréasson; Anders Bengtsson; Håkan Berggren; Rolf Ekroth; Lena Lindholm; John Ouchterlony
Journal:  Ann Thorac Surg       Date:  2003-03       Impact factor: 4.330

View more
  21 in total

1.  In-vitro quantification of gaseous microemboli in two extracorporeal life support circuits.

Authors:  Jeffrey Burnside; Daniel Gomez; Thomas J Preston; Vincent F Olshove; Alistair Phillips
Journal:  J Extra Corpor Technol       Date:  2011-09

2.  Optimizing venous drainage using an ultrasonic flow probe on the venous line.

Authors:  Joshua L Walker; Haven A Young; D Scott Lawson; S Adil Husain; John H Calhoon
Journal:  J Extra Corpor Technol       Date:  2011-09

3.  Australian and New Zealand perfusion survey: equipment and monitoring.

Authors:  Robert A Baker; Timothy W Willcox
Journal:  J Extra Corpor Technol       Date:  2006-09

4.  Retrospective analysis comparing hollow fiber and silicone membrane oxygenators for neonates on ECMO.

Authors:  Brian Mejak; Carmen Giacomuzzi; Eileen Heller; Xiaomang You; Ross Ungerleider; Irving Shen
Journal:  J Extra Corpor Technol       Date:  2007-06

5.  The fall of Sardis: the power of observation.

Authors:  Robert C Groom
Journal:  J Extra Corpor Technol       Date:  2008-09

6.  International Pediatric Perfusion Practice: 2016 Survey Results.

Authors:  Ashley Walcƶak; Thomas Klein; Jordan Voss; Vincent Olshove; Rajeev Gupta; Tatiana Averina; Luiz Caneo; Robert Groom
Journal:  J Extra Corpor Technol       Date:  2021-03

7.  International pediatric perfusion practice: 2011 survey results.

Authors:  Brian Harvey; Kenneth G Shann; David Fitzgerald; Brian Mejak; Donald S Likosky; Luc Puis; Robert A Baker; Robert C Groom
Journal:  J Extra Corpor Technol       Date:  2012-12

Review 8.  Improvements in survival and neurodevelopmental outcomes in surgical treatment of hypoplastic left heart syndrome: a meta-analytic review.

Authors:  Joseph J Sistino; Heather Shaw Bonilha
Journal:  J Extra Corpor Technol       Date:  2012-12

9.  North American neonatal extracorporeal membrane oxygenation (ECMO) devices and team roles: 2008 survey results of Extracorporeal Life Support Organization (ELSO) centers.

Authors:  D Scott Lawson; Andrea F Lawson; Rich Walczak; Craig McRobb; Patty McDermott; Ian R Shearer; Andrew Lodge; James Jaggers
Journal:  J Extra Corpor Technol       Date:  2008-09

10.  Clinical evaluation of the Terumo Capiox FX05 hollow fiber oxygenator with integrated arterial line filter.

Authors:  Joseph Deptula; Melinda Valleley; Kimberly Glogowski; John Detwiler; James Hammel; Kim Duncan
Journal:  J Extra Corpor Technol       Date:  2009-12
View more