Patient dosimetry for hybrid MRI-radiotherapy systems.

C Kirkby1, T Stanescu, S Rathee, M Carlone, B Murray, B G Fallone.   

Abstract

A novel geometry has been proposed for a hybrid magnetic resonance imaging (MRI)-linac system in which a 6 MV linac is mounted on the open end of a biplanar, low field (0.2 T) MRI magnet on a single gantry that is free to rotate around the patient. This geometry creates a scenario in which the magnetic field vector remains fixed with respect to the incident photon beam, but moves with respect to the patient as the gantry rotates. Other proposed geometries are characterized by a radiation source rotating about a fixed cylindrical magnet where the magnetic field vector remains fixed with respect to the patient. In this investigation we simulate the inherent dose distribution patterns within the two MRI-radiation source geometries using PENELOPE and EGSnrc Monte Carlo radiation transport codes with algorithms implemented to account for the magnetic field deflection of charged particles. Simulations are performed in phantoms and for clinically realistic situations. The novel geometry results in a net Lorentz force that remains fixed with respect to the patient (in the cranial-caudal direction) and results in a cumulative influence on dose distribution for a multiple beam treatment scenario. For a case where patient anatomy is reasonably homogeneous (brain plan), differences in dose compared to a conventional (no magnetic field) case are minimal for the novel geometry. In the case of a lung plan where the inhomogeneous patient anatomy allows for the magnetic field to have significant influence on charged particle transport, larger differences occur in a predictable manner. For a system using a fixed cylindrical geometry and higher magnetic field (1.5 T), differences from the case without a magnetic field are significantly greater.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18404937     DOI: 10.1118/1.2839104

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  21 in total

1.  Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems.

Authors:  M Lamey; J Yun; B Burke; S Rathee; B G Fallone
Journal:  Phys Med Biol       Date:  2010-01-20       Impact factor: 3.609

2.  A study of the effect of in-line and perpendicular magnetic fields on beam characteristics of electron guns in medical linear accelerators.

Authors:  Dragoş E Constantin; Rebecca Fahrig; Paul J Keall
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

3.  Monte Carlo simulations of patient dose perturbations in rotational-type radiotherapy due to a transverse magnetic field: a tomotherapy investigation.

Authors:  Y M Yang; M Geurts; J B Smilowitz; E Sterpin; B P Bednarz
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

4.  New concept on an integrated interior magnetic resonance imaging and medical linear accelerator system for radiation therapy.

Authors:  Xun Jia; Zhen Tian; Yan Xi; Steve B Jiang; Ge Wang
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-02

Review 5.  Magnetic resonance image guidance in external beam radiation therapy planning and delivery.

Authors:  Ilamurugu Arivarasan; Chandrasekaran Anuradha; Shanmuga Subramanian; Ayyalusamy Anantharaman; Velayudham Ramasubramanian
Journal:  Jpn J Radiol       Date:  2017-06-13       Impact factor: 2.374

6.  Comparison of dose decrement from intrafraction motion for prone and supine prostate radiotherapy.

Authors:  Jeffrey R Olsen; Parag J Parikh; Michael Watts; Camille E Noel; Kenneth W Baker; Lakshmi Santanam; Jeff M Michalski
Journal:  Radiother Oncol       Date:  2012-07-17       Impact factor: 6.280

7.  An integrated approach to segmentation and nonrigid registration for application in image-guided pelvic radiotherapy.

Authors:  Chao Lu; Sudhakar Chelikani; Xenophon Papademetris; Jonathan P Knisely; Michael F Milosevic; Zhe Chen; David A Jaffray; Lawrence H Staib; James S Duncan
Journal:  Med Image Anal       Date:  2011-05-20       Impact factor: 8.545

8.  Patient-specific quality assurance for the delivery of (60)Co intensity modulated radiation therapy subject to a 0.35-T lateral magnetic field.

Authors:  H Harold Li; Vivian L Rodriguez; Olga L Green; Yanle Hu; Rojano Kashani; H Omar Wooten; Deshan Yang; Sasa Mutic
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-10-25       Impact factor: 7.038

9.  Radiation induced currents in MRI RF coils: application to linac/MRI integration.

Authors:  B Burke; B G Fallone; S Rathee
Journal:  Phys Med Biol       Date:  2010-01-13       Impact factor: 3.609

10.  Technical Note: A Monte Carlo study of magnetic-field-induced radiation dose effects in mice.

Authors:  Ashley E Rubinstein; Zhongxing Liao; Adam D Melancon; Michele Guindani; David S Followill; Ramesh C Tailor; John D Hazle; Laurence E Court
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.