Literature DB >> 15971313

Moving targets: detection and tracking of internal organ motion for treatment planning and patient set-up.

Eike Rietzel1, Stanley J Rosenthal, David P Gierga, Christopher G Willet, George T Y Chen.   

Abstract

BACKGROUND AND
PURPOSE: Clinical target volumes of the thorax and abdomen are typically expanded to account for inter- and intrafractional organ motion. Usually, such expansions are based on clinical experience and planar observations of target motion during simulation. More precise, 4-dimensional motion margins for a specific patient may improve dose coverage of mobile targets and yet limit unnecessarily large field expansions. We are studying approaches to targeting moving tumors throughout the entire treatment process, from treatment planning to beam delivery.
MATERIAL AND METHODS: Radio-opaque markers were implanted under CT guidance in the liver at the gross tumor periphery. Organ motion during light respiration was volumetrically imaged by 4D Computed Tomography. Marker motion was also acquired by fluoroscopy and compared with 4DCT data. During treatment, daily diagnostic x-ray images were captured at end-exhale and -inhale for patient setup and target localization.
RESULTS: Based on the time-resolved CT data, target volumes can be designed to account for respiratory motion during treatment. Motion of the tumor as derived from 4DCT was consistent with fluoroscopic motion analysis. Radiographs acquired in the treatment room enabled millimeter-level patient set-up and assessment of target position relative to bony anatomy. Daily positional variations between bony anatomy and implanted markers were observed.
CONCLUSIONS: Image guided therapy, based on 4DCT imaging, fluoroscopic imaging studies, and daily gated diagonstic energy set-up radiographs is being developed to improve beam delivery precision. Monitoring internal target motion throughout the entire treatment process will ensure adequate dose coverage of the target while sparing the maximum healthy tissue.

Entities:  

Mesh:

Year:  2004        PMID: 15971313     DOI: 10.1016/s0167-8140(04)80018-5

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  16 in total

Review 1.  Imaging and image-guided radiation therapy in liver cancer.

Authors:  Kristy K Brock
Journal:  Semin Radiat Oncol       Date:  2011-10       Impact factor: 5.934

2.  A novel technique for markerless, self-sorted 4D-CBCT: feasibility study.

Authors:  Irina Vergalasova; Jing Cai; Fang-Fang Yin
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

Review 3.  [Radiotherapy of hepatic metastases].

Authors:  S E Combs; K K Herfarth; D Habermehl; J Debus
Journal:  Chirurg       Date:  2010-06       Impact factor: 0.955

4.  Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems.

Authors:  M Lamey; J Yun; B Burke; S Rathee; B G Fallone
Journal:  Phys Med Biol       Date:  2010-01-20       Impact factor: 3.609

Review 5.  Adaptive management of liver cancer radiotherapy.

Authors:  Kristy K Brock; Laura A Dawson
Journal:  Semin Radiat Oncol       Date:  2010-04       Impact factor: 5.934

6.  Potential underestimation of the internal target volume (ITV) from free-breathing CBCT.

Authors:  Irina Vergalasova; Jacqueline Maurer; Fang-Fang Yin
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

7.  Evaluation of anatomical landmark position differences between respiration-gated MRI and four-dimensional CT for radiation therapy in patients with hepatocellular carcinoma.

Authors:  J I Yu; J S Kim; H C Park; D H Lim; Y Y Han; H C Lim; S W Paik
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

Review 8.  [Computed tomography of the lungs. A step into the fourth dimension].

Authors:  J Dinkel; C Hintze; N Rochet; C Thieke; J Biederer
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

Review 9.  [Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI].

Authors:  J Biederer; C Hintze; M Fabel; J Dinkel
Journal:  Radiologe       Date:  2009-08       Impact factor: 0.635

10.  Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm.

Authors:  Krishni Wijesooriya; E Weiss; V Dill; L Dong; R Mohan; S Joshi; P J Keall
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.