Literature DB >> 20087776

The effects of concentric ring electrode electrical stimulation on rat skin.

W Besio1, V Sharma, J Spaulding.   

Abstract

Surface electrodes are commonly used electrodes clinically, in applications such as functional electrical stimulation for the restoration of motor functions, pain relief, transcutaneous electrical nerve stimulation, electrocardiographic monitoring, defibrillation, surface cardiac pacing, and advanced drug delivery systems. Common to these applications are occasional reports of pain, tissue damage, rash, or burns on the skin at the point where electrodes are placed. In this study, we quantitatively analyzed the effects of acute noninvasive electrical stimulation from concentric ring electrodes (CRE) to determine the maximum safe current limit. We developed a three-dimensional multi-layer model and calculated the temperature profile under the CRE and the corresponding energy density with electrical-thermal coupled field analysis. Infrared thermography was used to measure skin temperature during electrical stimulation to verify the computer simulations. We also performed histological analysis to study cell morphology and characterize any resulting tissue damage. The simulation results are accurate for low energy density distributions. It can also be concluded that as long as the specified energy density applied is kept below 0.92 (A2/cm4.s(-1)), the maximum temperature will remain within the safe limits. Future work should focus on the effects of the electrode paste.

Entities:  

Mesh:

Year:  2010        PMID: 20087776      PMCID: PMC2905673          DOI: 10.1007/s10439-009-9891-y

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  28 in total

1.  Burns as a complication of the use of diathermy.

Authors:  J W Vedovato; V P Pólvora; D F Leonardi
Journal:  J Burn Care Rehabil       Date:  2004 Jan-Feb

Review 2.  Electrical stimulation of excitable tissue: design of efficacious and safe protocols.

Authors:  Daniel R Merrill; Marom Bikson; John G R Jefferys
Journal:  J Neurosci Methods       Date:  2005-02-15       Impact factor: 2.390

3.  Burns of the skin caused by a peripheral-nerve stimulator.

Authors:  M Lippmann; W A Fields
Journal:  Anesthesiology       Date:  1974-01       Impact factor: 7.892

4.  Burns in functional electric stimulation: two case reports.

Authors:  M T Balmaseda; M T Fatehi; S H Koozekanani; J S Sheppard
Journal:  Arch Phys Med Rehabil       Date:  1987-07       Impact factor: 3.966

5.  Direct-current injury from external pacemaker results in tissue electrolysis.

Authors:  E A Grossi; M A Parish; M R Kralik; L R Glassman; R A Esposito; G H Ribakove; A C Galloway; S B Colvin
Journal:  Ann Thorac Surg       Date:  1993-07       Impact factor: 4.330

6.  Analysis and control of the current distribution under circular dispersive electrodes.

Authors:  J D Wiley; J G Webster
Journal:  IEEE Trans Biomed Eng       Date:  1982-05       Impact factor: 4.538

7.  Current-based transthoracic defibrillation.

Authors:  R E Kerber; R A Kieso; M G Kienzle; B Olshansky; A L Waldo; M D Carlson; D J Wilber; A M Aschoff; S Birger; F Charbonnier
Journal:  Am J Cardiol       Date:  1996-11-15       Impact factor: 2.778

8.  An investigation of the hypoalgesic effects of TENS delivered by a glove electrode.

Authors:  Stephen Cowan; Joanne McKenna; Evie McCrum-Gardner; Mark I Johnson; Kathleen A Sluka; Deirdre M Walsh
Journal:  J Pain       Date:  2009-04-23       Impact factor: 5.820

9.  Improvement of spatial selectivity and decrease of mutual information of tri-polar concentric ring electrodes.

Authors:  Kanthaiah Koka; Walter G Besio
Journal:  J Neurosci Methods       Date:  2007-06-15       Impact factor: 2.390

10.  Estimation of current density distribution under electrodes for external defibrillation.

Authors:  Vessela Tz Krasteva; Sava P Papazov
Journal:  Biomed Eng Online       Date:  2002-12-16       Impact factor: 2.819

View more
  7 in total

1.  Toward a noninvasive automatic seizure control system in rats with transcranial focal stimulations via tripolar concentric ring electrodes.

Authors:  Oleksandr Makeyev; Xiang Liu; Hiram Luna-Munguía; Gabriela Rogel-Salazar; Samuel Mucio-Ramirez; Yuhong Liu; Yan L Sun; Steven M Kay; Walter G Besio
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2012-07       Impact factor: 3.802

2.  Effects of transcranial focal electrical stimulation via tripolar concentric ring electrodes on pentylenetetrazole-induced seizures in rats.

Authors:  W G Besio; O Makeyev; A Medvedev; K Gale
Journal:  Epilepsy Res       Date:  2013-01-03       Impact factor: 3.045

3.  Transcranial focal electrical stimulation via tripolar concentric ring electrodes does not modify the short- and long-term memory formation in rats evaluated in the novel object recognition test.

Authors:  G Rogel-Salazar; H Luna-Munguía; K E Stevens; W G Besio
Journal:  Epilepsy Behav       Date:  2013-02-15       Impact factor: 2.937

4.  Noninvasive transcranial focal stimulation via tripolar concentric ring electrodes lessens behavioral seizure activity of recurrent pentylenetetrazole administrations in rats.

Authors:  Oleksandr Makeyev; Hiram Luna-Munguía; Gabriela Rogel-Salazar; Xiang Liu; Walter G Besio
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2012-06-05       Impact factor: 3.802

5.  Noninvasive pacing during transfemoral implantation of the Edwards SAPIEN valve for tricuspid valve bioprosthesis stenosis.

Authors:  Marcin Demkow; Witold Rużyłło; Sebastian Bujak; Marek Konka; Piotr Szatkowski; Barbara Lubiszewska
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-02-11       Impact factor: 1.426

6.  Case-study of a user-driven prosthetic arm design: bionic hand versus customized body-powered technology in a highly demanding work environment.

Authors:  Wolf Schweitzer; Michael J Thali; David Egger
Journal:  J Neuroeng Rehabil       Date:  2018-01-03       Impact factor: 4.262

7.  Safety of the Transcranial Focal Electrical Stimulation via Tripolar Concentric Ring Electrodes for Hippocampal CA3 Subregion Neurons in Rats.

Authors:  Samuel Mucio-Ramírez; Oleksandr Makeyev
Journal:  J Healthc Eng       Date:  2017-08-13       Impact factor: 2.682

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.