Literature DB >> 22772373

Toward a noninvasive automatic seizure control system in rats with transcranial focal stimulations via tripolar concentric ring electrodes.

Oleksandr Makeyev1, Xiang Liu, Hiram Luna-Munguía, Gabriela Rogel-Salazar, Samuel Mucio-Ramirez, Yuhong Liu, Yan L Sun, Steven M Kay, Walter G Besio.   

Abstract

Epilepsy affects approximately 1% of the world population. Antiepileptic drugs are ineffective in approximately 30% of patients and have side effects. We are developing a noninvasive, or minimally invasive, transcranial focal electrical stimulation system through our novel tripolar concentric ring electrodes to control seizures. In this study, we demonstrate feasibility of an automatic seizure control system in rats with pentylenetetrazole-induced seizures through single and multiple stimulations. These stimulations are automatically triggered by a real-time electrographic seizure activity detector based on a disjunctive combination of detections from a cumulative sum algorithm and a generalized likelihood ratio test. An average seizure onset detection accuracy of 76.14% was obtained for the test set (n = 13). Detection of electrographic seizure activity was accomplished in advance of the early behavioral seizure activity in 76.92% of the cases. Automatically triggered stimulation significantly (p = 0.001) reduced the electrographic seizure activity power in the once stimulated group compared to controls in 70% of the cases. To the best of our knowledge this is the first closed-loop automatic seizure control system based on noninvasive electrical brain stimulation using tripolar concentric ring electrode electrographic seizure activity as feedback.

Entities:  

Mesh:

Year:  2012        PMID: 22772373      PMCID: PMC3525521          DOI: 10.1109/TNSRE.2012.2197865

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  43 in total

Review 1.  The use of "overall accuracy" to evaluate the validity of screening or diagnostic tests.

Authors:  Anthony J Alberg; Ji Wan Park; Brant W Hager; Malcolm V Brock; Marie Diener-West
Journal:  J Gen Intern Med       Date:  2004-05       Impact factor: 5.128

2.  Analysis and control of the current distribution under circular dispersive electrodes.

Authors:  J D Wiley; J G Webster
Journal:  IEEE Trans Biomed Eng       Date:  1982-05       Impact factor: 4.538

Review 3.  Possible therapeutic effects of transcutaneous electrical stimulation via concentric ring electrodes.

Authors:  Walter G Besio; Karen N Gale; Andrei V Medvedev
Journal:  Epilepsia       Date:  2010-07       Impact factor: 5.864

4.  Patient and caregiver perspectives on seizure prediction.

Authors:  Susan Arthurs; Hitten P Zaveri; Mark G Frei; Ivan Osorio
Journal:  Epilepsy Behav       Date:  2010-09-20       Impact factor: 2.937

5.  Comprehensive analysis of risk factors for seizures after deep brain stimulation surgery. Clinical article.

Authors:  Nader Pouratian; Davis L Reames; Robert Frysinger; W Jeff Elias
Journal:  J Neurosurg       Date:  2011-05-06       Impact factor: 5.115

6.  Double-blind, randomized controlled pilot study of bilateral cerebellar stimulation for treatment of intractable motor seizures.

Authors:  Francisco Velasco; José D Carrillo-Ruiz; Francisco Brito; Marcos Velasco; Ana Luisa Velasco; Irma Marquez; Ross Davis
Journal:  Epilepsia       Date:  2005-07       Impact factor: 5.864

7.  Transcranial direct current stimulation decreases convulsions and spatial memory deficits following pilocarpine-induced status epilepticus in immature rats.

Authors:  Tohru Kamida; Shiqi Kong; Nobuoki Eshima; Tatsuya Abe; Minoru Fujiki; Hidenori Kobayashi
Journal:  Behav Brain Res       Date:  2010-09-06       Impact factor: 3.332

8.  Algorithm for automatic detection of pentylenetetrazole-induced seizures in rats.

Authors:  W G Besio; X Liu; Y Liu; Y L Sun; A V Medvedev; K Koka
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

9.  Vagus nerve stimulation for treatment of partial seizures: 1. A controlled study of effect on seizures. First International Vagus Nerve Stimulation Study Group.

Authors:  E Ben-Menachem; R Mañon-Espaillat; R Ristanovic; B J Wilder; H Stefan; W Mirza; W B Tarver; J F Wernicke
Journal:  Epilepsia       Date:  1994 May-Jun       Impact factor: 5.864

10.  Transcranial magnetic stimulation for the treatment of seizures: a controlled study.

Authors:  W H Theodore; K Hunter; R Chen; F Vega-Bermudez; B Boroojerdi; P Reeves-Tyer; K Werhahn; K R Kelley; L Cohen
Journal:  Neurology       Date:  2002-08-27       Impact factor: 9.910

View more
  7 in total

1.  Transcranial focal electrical stimulation via tripolar concentric ring electrodes does not modify the short- and long-term memory formation in rats evaluated in the novel object recognition test.

Authors:  G Rogel-Salazar; H Luna-Munguía; K E Stevens; W G Besio
Journal:  Epilepsy Behav       Date:  2013-02-15       Impact factor: 2.937

2.  Improving the accuracy of Laplacian estimation with novel multipolar concentric ring electrodes.

Authors:  Oleksandr Makeyev; Quan Ding; Walter G Besio
Journal:  Measurement (Lond)       Date:  2016-02-01       Impact factor: 3.927

3.  High-Frequency Oscillations Recorded on the Scalp of Patients With Epilepsy Using Tripolar Concentric Ring Electrodes.

Authors:  Walter G Besio; Iris E Martínez-Juárez; Oleksandr Makeyev; John N Gaitanis; Andrew S Blum; Robert S Fisher; Andrei V Medvedev
Journal:  IEEE J Transl Eng Health Med       Date:  2014-06-30       Impact factor: 3.316

4.  Automatic seizure detection in rats using Laplacian EEG and verification with human seizure signals.

Authors:  Amal Feltane; G Faye Boudreaux-Bartels; Walter Besio
Journal:  Ann Biomed Eng       Date:  2012-10-17       Impact factor: 3.934

5.  Safety of the Transcranial Focal Electrical Stimulation via Tripolar Concentric Ring Electrodes for Hippocampal CA3 Subregion Neurons in Rats.

Authors:  Samuel Mucio-Ramírez; Oleksandr Makeyev
Journal:  J Healthc Eng       Date:  2017-08-13       Impact factor: 2.682

6.  Improving the Accuracy of Laplacian Estimation with Novel Variable Inter-Ring Distances Concentric Ring Electrodes.

Authors:  Oleksandr Makeyev; Walter G Besio
Journal:  Sensors (Basel)       Date:  2016-06-10       Impact factor: 3.576

7.  Solving the general inter-ring distances optimization problem for concentric ring electrodes to improve Laplacian estimation.

Authors:  Oleksandr Makeyev
Journal:  Biomed Eng Online       Date:  2018-08-30       Impact factor: 2.819

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.