Literature DB >> 20082776

Application of a new potentiometric method for determination of phosphate based on a surfactant-modified zeolite carbon-paste electrode (SMZ-CPE).

Alireza Nezamzadeh Ejhieh1, Neda Masoudipour.   

Abstract

A phosphate-selective electrode based on surfactant-modified zeolite (SMZ) particles into carbon-paste has been proposed (SMZ-CPE). The electrode was fully characterized in terms of composition, response time, ionic strength, thermal stability and usable pH range. The electrode containing 20% SMZ exhibited linear response range to phosphate species in the range of 1.58 x 10(-5) to 1.00 x 10(-2) M with a detection limit of 1.28 x 10(-5) M and a Nernstian slope of 29.9+/-0.9 mV per decade of phosphate concentration. The electrode response to phosphate remains constant in the pH range of 4-12 and in the presence of 1 x 10(-4) to 4 x 10(-3) M NaNO(3). The response of the electrode reaches equilibrium within several seconds after immersing the electrode in phosphate solution. Common anions such as Cl(-), Br(-), I(-), NO(3)(-), SO(4)(2-) and Cr(2)O(7)(2-) have little effect on the determination of phosphate but AsO(4)(3-) shows some interference. A successful application of the electrode for determination of phosphate in a fertilizer, using direct potentiometry, is presented. The electrode was also used for the potentiometric titration of phosphate. The validation of the obtained results in each case was proved by statistical methods. Copyright 2009 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20082776     DOI: 10.1016/j.aca.2009.10.064

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  5 in total

1.  Dye removal of AR27 with enhanced degradation and power generation in a microbial fuel cell using bioanode of treated clinoptilolite-modified graphite felt.

Authors:  Seyedeh Nazanin Kardi; Norahim Ibrahim; Ghasem Najafpour Darzi; Noor Aini Abdul Rashid; José Villaseñor
Journal:  Environ Sci Pollut Res Int       Date:  2017-06-03       Impact factor: 4.223

2.  Maize tassel-modified carbon paste electrode for voltammetric determination of Cu(II).

Authors:  Mambo Moyo; Jonathan O Okonkwo; Nana M Agyei
Journal:  Environ Monit Assess       Date:  2014-04-06       Impact factor: 2.513

3.  Printed Electrode for Measuring Phosphate in Environmental Water.

Authors:  Alisha Prasad; Sushant P Sahu; Sara Karoline Figueiredo Stofela; Ardalan Chaichi; Syed Mohammad Abid Hasan; Wokil Bam; Kanchan Maiti; Kevin M McPeak; Gang Logan Liu; Manas Ranjan Gartia
Journal:  ACS Omega       Date:  2021-04-22

Review 4.  Surfactant modified/mediated thin-layer chromatographic systems for the analysis of amino acids.

Authors:  Showkat A Bhawani; Hassan M Albishri; Ziya Ahmad Khan; Mohamad N Mohamad Ibrahim; A Mohammad
Journal:  J Anal Methods Chem       Date:  2013-12-21       Impact factor: 2.193

5.  Online Coupling of Lab-on-Valve Format to Amperometry Based on Polyvinylpyrrolidone-Doped Carbon Paste Electrode and Its Application to the Analysis of Morin.

Authors:  Yang Wang; Guojun Yao; Jie Tang; Chun Yang; Qin Xu; Xiaoya Hu
Journal:  J Anal Methods Chem       Date:  2012-04-05       Impact factor: 2.193

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.