Alisha Prasad1, Sushant P Sahu1, Sara Karoline Figueiredo Stofela2, Ardalan Chaichi1, Syed Mohammad Abid Hasan1, Wokil Bam3, Kanchan Maiti3, Kevin M McPeak2, Gang Logan Liu4, Manas Ranjan Gartia1. 1. Department of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, Louisiana 70803, United States. 2. Department of Chemical Engineering, Louisiana State University, Baton Rouge, Louisiana 70803, United States. 3. Department of Oceanography and Coastal Sciences, Louisiana State University, Baton Rouge, Louisiana 70803, United States. 4. Department of Electrical and Computer Engineering, University of Illinois, Urbana-Champaign, Illinois 61801, United States.
Abstract
Phosphate is a major nonpoint source pollutant in both the Louisiana local streams as well as in the Gulf of Mexico coastal waters. Phosphates from agricultural run-off have contributed to the eutrophication of global surface waters. Phosphate environmental dissemination and eutrophication problems are not yet well understood. Thus, this study aimed to monitor phosphate in the local watershed to help identify potential hot spots in the local community (Mississippi River, Louisiana) that may contribute to nutrient loading downstream (in the Gulf of Mexico). An electrochemical method using a physical vapor deposited cobalt microelectrode was utilized for phosphate detection using cyclic voltammetry and amperometry. The testing results were utilized to evaluate the phosphate distribution in river water and characterize the performance of the microsensor. Various characterizations, including the limit of detection, sensitivity, and reliability, were conducted by measuring the effect of interferences, including dissolved oxygen, pH, and common ions. The electrochemical sensor performance was validated by comparing the results with the standard colorimetry phosphate detection method. X-ray photoelectron spectroscopy (XPS) measurements were performed to understand the phosphate sensing mechanism on the cobalt electrode. This proof-of-concept sensor chip could be utilized for on-field monitoring using a portable, hand-held potentiostat.
class="Chemical">Phosphate is a major nonclass="Chemical">point source class="Chemical">pollutant in both the Louisiana local streams as well as in the Gulf of Mexiclass="Chemical">pan class="Chemical">co coastal waters. Phosphates from agricultural run-off have contributed to the eutrophication of global surface waters. Phosphateenvironmental dissemination and eutrophication problems are not yet well understood. Thus, this study aimed to monitor phosphate in the local watershed to help identify potential hot spots in the local community (Mississippi River, Louisiana) that may contribute to nutrient loading downstream (in the Gulf of Mexico). An electrochemical method using a physical vapor deposited cobalt microelectrode was utilized for phosphate detection using cyclic voltammetry and amperometry. The testing results were utilized to evaluate the phosphate distribution in river water and characterize the performance of the microsensor. Various characterizations, including the limit of detection, sensitivity, and reliability, were conducted by measuring the effect of interferences, including dissolved oxygen, pH, and common ions. The electrochemical sensor performance was validated by comparing the results with the standard colorimetry phosphate detection method. X-ray photoelectron spectroscopy (XPS) measurements were performed to understand the phosphate sensing mechanism on the cobalt electrode. This proof-of-concept sensor chip could be utilized for on-field monitoring using a portable, hand-held potentiostat.
Population
growth, class="Species">environmentally unsound agricultural class="Chemical">practices,
and increased industrialization are the class="Chemical">prime drivers in the accumulation
of excessive nutrients (class="Chemical">pan class="Chemical">nitrate, phosphate, ammonia) in water bodies,
leading to eutrophication.[1,2] This eutrophication
of water bodies results in algal blooms and low oxygen levels, referred
to as hypoxic water, that can kill fish and seagrass, impacting the
viable habitat available to aquatic life. It can also lead to harmful
algal blooms (HABs) that affect the biological lifecycle, human health,
and natural beauty.[3−5] Total phosphorous (P) in the concentration range
of 0.02–0.1 mgL–1 is considered the amount
defining the onset of eutrophication in water bodies where P is the
limiting nutrient.[6−8] Even in bodies of water where P is not the limiting
nutrient, the N/P ratio can determine the phytoplankton communities
and the development of HABs.[9−11] For these reasons, The U.S. Environmental
Protection Agency (EPA) has set the maximum allowable contaminant
level (MCL) for total phosphorus to 0.05 to 0.5 mg L–1.[12] However, phosphorus measurement at
such low concentrations in natural water on a routine basis to check
for eutrophication is challenging. Currently, the only EPA-approved
method for phosphorus detection is the spectrophotometric-based Method
365.5.[13] In this approach, dissolved and/or
suspended orthophosphates react with a cocktail of reagents such as
ammonium molybdate, antimony potassium tartarate, and ascorbic acid
in an acidic medium to produce a blue complex, the optical absorbance
of which is measured spectrophotometrically.[14] Although this method is sensitive to the detection of low concentrations
of phosphate, its disadvantages include decay in color, refractive
index errors, and turbidity interferences.[15,16] Besides, since this method relies on a batch process, it is not
suitable for field implementation or online monitoring systems. However,
some of these disadvantages have been addressed recently by quickly
measuring the final sample analytes,[17] using
high-quality quartz cuvettes,[18] and filtering
samples to measure the soluble reactive phosphorus (SRP) and blank
corrections.[19]
The primary advantage
of using in situ sensors
in the class="Chemical">molybdate-sclass="Chemical">pectrosclass="Chemical">pan class="Chemical">copy method is that it allows for obtaining
data in real time, monitoring at the higher temporal resolution, and
reducing the cost. Researchers have also automated the classic colorimetric
molybdenum-blue batch method of phosphate sensing, developing a Lab-On-Chip
(LOC) Phosphate Analyzer using microfluidics[20] and optofluidic systems[21] for the detection
of phosphate in oceans. However, these colorimetric-based methods
experience decay in color over time; since a bulky and power-intensive
system is utilized, continuous monitoring with high throughput is
challenging. Despite these disadvantages, commercial systems such
as Sea-Bird Scientific’s HydroCycle-PO4 Phosphate Sensor (OTT
HydroMet, USA) and the A1000 Phosphate sensor (Dartmouth Ocean Technologies
Inc., USA) are available to perform in situ measurements
of phosphate at sea.
Recently, alternative approaches such as
electrochemical class="Chemical">phosphate
detection have received much attention due to their class="Chemical">potential for
miniaturization. Several studies have reclass="Chemical">ported enzyme-based electrodes,[22,23] class="Chemical">pan class="Chemical">carbon paste electrodes,[24,25] and glassy carbon electrodes[26] for detecting phosphate. The amperometric or
voltammetric signals obtained are based on the oxidation–reduction
complex formed due to redox reactions of cobalt. Past research has
reported that cobalt-based sensors have achieved a limit of detection
(LOD) in the micromoles per liter range. Furthermore, phosphate sensors
utilizing enzyme-based electrodes experience enzyme inactivity when
used for a long period of time and potential issues with reproducibility
in fabricating the enzyme immobilized electrodes with a proper enzyme
orientation to sense phosphate analyte. On the other hand, the sensitivity
of carbon-based electrodes is limited due to high electrochemical
noise. To address this limitation, several studies have researched
the use of ion selective metal electrodes such as cobalt wire,[27] cobalt microelectrodes,[28,29] cobalt screen printed electrodes,[30,31] and lead wire[32] for phosphate detection. Among these, cobalt
is an attractive choice as it produces a high signal-to-noise ratio
and can be miniaturized through physical vapor deposition (PVD) methods,
although it can experience oxidation upon repetitive use. As the use
of lead as a working electrode is limited due to its toxicity issues,
here, we used cobalt as the working electrode. Since our goal is to
develop field-applicable single-use sensor chips, metal oxidation
can be tolerated.
Although significant progress has been made
in the development
of in situ class="Chemical">phosphate sensors,[31,33−36] the transclass="Chemical">port of class="Chemical">pan class="Chemical">phosphate ions in environmentalwater leading to
eutrophication is not yet well understood. Because the increase in
phosphoruscontamination is reaching critical levels in water basins
around the globe, there is an urgent need to understand the transport
of nutrients and devise a strategy to mitigate these pollutants at
the local watershed. To actively manage the nutrients leading to environmentally
compromised water bodies, we need to first measure them. Given this
motivation, the aim of this research was to develop in situ sensors for the electrochemical detection of phosphate in environmentalwater.
This work is one of the first to monitor class="Chemical">phosphate in
the local
class="Chemical">pan class="Chemical">watershed to help recognize possible ″hot spots″ in
the local community that may be contributing to nutrient stacking
downstream. First, electrochemical methods using cyclic voltammetry
and amperometry were utilized to detect phosphate in water samples.
We used a cobalt-based miniaturized working electrode for the continuous
detection of phosphate (quasi-transient) in water samples over a one
month period. We evaluated the performance of the sensor by rigorously
establishing the limit of detection, the effect of additional parameters
such as pH and dissolved oxygen, and the presence of interfering ions
in the water samples. Furthermore, the performance of the sensor was
compared with the standard color-based phosphate detection method
using spectrophotometry.
Results and Discussion
Electrochemical Phosphate Sensing and Evaluation
of Dynamic Range
Acclass="Chemical">cording to the Henderson–Hasselbalch
equation, the dissociation of class="Chemical">pan class="Chemical">KH2PO4 followswhere the potassium dihydrogen
phosphate (KH2PO4) ionizes under equilibrium
conditions at pH ∼ 4 into two species: dihydrogen phosphate
(H2PO4–), a weak acid, and hydrogen phosphate (HPO42–), its conjugate base. At pH ∼ 4 and pKa = 7.198,
[HPO42–/H2PO4–] = 3 × 10–3, meaning that the
species we are detecting using the electrochemical measurement will
predominantly be H2PO4– (the
eq 4 complex in Supplementary Information Section S1 represents the same result). As phosphate sensing in the
biological environment is challenging, this study used the electrochemical
method for signal transduction and direct conversion of the biological
analyte to a detectable electronic signal. Electrochemical responses
were recorded by performing CV measurements involving redox reactions
(oxidation and reduction) occurring on the working electrode surface. Figure a shows the CV curve
obtained at a scan rate of 50 mV/s for the cobalt sensor in a 25 mM
potassium hydrogen phthalate (KHP) buffer with a pH ∼ 4. Eight
concentrations of standard phosphate solution (orthophosphate) were
prepared in the range of 10–7 to 10–4 M KH2PO4 for calibration. H2PO4– was the dominant species at this pH range.
The CV curve was obtained by scanning the potential from −1.4
to 0.4 V vs Ag/AgCl. The current–potential (I–V) curve showed anodic current at 0.4 V
due to the oxidation of Co0 to Co2+. Furthermore,
due to the reduction of Co2+ to Co0, a cathodic
current wave was generated with a reduction peak around −1.0
V, a result that agrees with the values found in the literature.[31]
Figure 1
Cyclic voltammetry (CV) results using the phosphate sensor.
(a)
Cyclic voltammograms with a cobalt wire as the working electrode,
Ag/AgCl as the reference electrode, and Pt wire as the counter electrode
in a 25 mM KHP buffer and 1 mM KCl with KH2PO4 in a concentration range of 1 to 100 μM at a scan rate of
50 mV/s. (b) Phosphate sensor calibration curve showing a linear range
of detection from 1 to 100 μM with bulk cobalt wire. The current
signal obtained from the buffer was subtracted from all sample peak
currents. (c) Effect of scan rate from 25 to 1350 mV/s on the performance
of the phosphate sensor at a constant phosphate concentration (∼10–6 M). Inset shows I vs scan rate0.5. (d) E vs scan rate0.5.
Cyclic voltammetry (CV) results using the class="Chemical">phosphate sensor.
(a)
Cyclic voltammograms with a class="Chemical">pan class="Chemical">cobalt wire as the working electrode,
Ag/AgCl as the reference electrode, and Pt wire as the counter electrode
in a 25 mM KHP buffer and 1 mM KCl with KH2PO4 in a concentration range of 1 to 100 μM at a scan rate of
50 mV/s. (b) Phosphate sensor calibration curve showing a linear range
of detection from 1 to 100 μM with bulk cobalt wire. The current
signal obtained from the buffer was subtracted from all sample peak
currents. (c) Effect of scan rate from 25 to 1350 mV/s on the performance
of the phosphate sensor at a constant phosphateconcentration (∼10–6 M). Inset shows I vs scan rate0.5. (d) E vs scan rate0.5.
Figure b shows
the calibration curve for class="Chemical">phosphate ions in the range of 10–7 to 10–4 M class="Chemical">pan class="Chemical">KH2PO4 calculated
from the CV measurement data. It shows a linear relationship over
the dynamic range with a slope of 0.05 μA/decade. The dynamic
range found here is at least two orders of magnitude broader than
previously reported values. (The previously reported dynamic range
was from 10–5 to 10–2 M.[27,28,31,37,38]) All of our electrochemical experiments
were conducted at 50 mV/s as the CV curves were stable at this scan
rate with a good reduction peak at approximately −1.05 V. The
limit of detection of the cobalt-wire sensor was estimated to be ∼10–7 M using the relationship 3σb, where
σb is the standard deviation of the buffer solution
containing no phosphate. Experiments were conducted at least three
times at each concentration to determine the standard deviation. The
magnitude of the current response of the buffer was subtracted from
all sample peak current responses to plot the calibration curve. The R2 coefficient of the linear fit is 0.996.
The quasi-reversible electron transfer process in the resulting
cyclic voltammograms can be represented by the Randles–Sevcik
equation below:where ipc is the peak current, n is the number of
electrons transferred, A is the area of the electrode,
α is the electron transfer class="Chemical">coefficient, D is
the diffusion class="Chemical">pan class="Chemical">coefficient, v is the scan rate, and C is the concentration of the bulk solution. Figure c shows the CV curve at different
scan rates from 25 to 1350 mV/s, and the inset plot of the I vs scan rate0.5 shows that at high scan rates
(where v0.5 is small), the cobalt redox
couple exhibits an irreversible behavior. Since the couple exhibits
an expected reversible behavior up to a scan rate of 200 mV/s, all
CV experiments were conducted at 50 mV/s.
The deviation of the
peak potential E vs scan
rate0.5 is shown in Figure d.The class="Chemical">kinetics of the chemical reaction and
the diffusion of class="Chemical">pan class="Chemical">orthophosphate
ions from the solution to the electrodes were further explored using
chronoamperometry (CA). Supplementary Information Figure S2 shows the current–time profile for the phosphate
ions at various concentrations ranging from 10–7 to 10–4 M KH2PO4, obtained
by setting the working electrode at 0.25 V at a step time of 40 s
against an Ag/AgCl electrode. The plot in Figure S2a shows an increase in current with an increase in analyte
concentration, as demonstrated by the step responses. The plot in Figure S2b of the calibration curve for the orthophosphate
ions calculated from the CA measurements data shows a linear relationship
over the dynamic range with a slope of 0.13 μA/decade.
To evaluate the diffusion of the species on the class="Chemical">cobalt electrode
surface, we class="Chemical">plotted the current–time class="Chemical">profile for the class="Chemical">pan class="Chemical">phosphate
ions at individual concentrations and extrapolated the diffusion coefficient
using the Cottrell[39] equation:where I is
the current (A), n (≈4) is the number of electrons
reduced or oxidized, F is the Faraday constant (96,485
C/mol), A is the area of the electrode (1.85 cm2), D is the diffusion coefficient (cm2/s), C is the concentration of the reducible
analyte (mol/cm3), and t is the time (s). Figure a shows the plot
of I vs t at different concentrations.
The diffusion coefficient at 5 μM (∼5 × 10–9 mol/cm3) phosphateconcentration calculated using eq at t =
10 s and I = 2.94 μA was found to be 2.1 ×
10–5 cm2/s. The calculated value of the
diffusion coefficient is in good agreement with the literature value
of the diffusion coefficient of PO43– in water (which is ∼1 × 10–5 cm2/s[40]), while in the flocs, it is
7.6 × 10–5 m2 d–1.[41] The plot in Figure b shows the calibration curve for the orthophosphate
ions obtained from the measurement data in Figure a.
Figure 2
Current–time response
profile of the phosphate sensor. (a)
Chronoamperograms showing the phosphate sensor response at different
phosphate concentrations. (b) Phosphate sensor calibration curve showing
a linear range of detection from 5 × 10–7 to
5 × 10–4 M with bulk cobalt wire. The current
signal obtained from the buffer was subtracted from all sample peak
currents. The intra-assay coefficient of the variation percentage
(CV%) (n = 8) was calculated to be 4.4%. (c) Evaluation
of cobalt sensor response in the pH range of 2 to 8. Square wave pulsed
voltammograms show the characteristic cathodic current of 10–4 M aqueous KH2PO4 at various pH ranges from
2 to 8 in a 25 mM KHP buffer and 1 mM KCl at a scan rate of 50 mV/s.
(d) Evaluation of the effect of dissolved oxygen on the cobalt phosphate
sensor. Inset: Difference in current response measured at the cathodic
peak potential (−1.05 V). (e) Evaluation of the electrochemical
stability of the cobalt-based phosphate sensor at a fixed phosphate
concentration (∼10–5 M). Inset: Variation
in the current response measured at the cathodic peak potential (−1.05
V) for 10 measurements. (f) Evaluation of the cobalt sensor response
in the presence of various interfering cations. The bar graph shows
the change in the current response measured at the cathodic peak potential
(−1.05 V). Left to right: nitrate (0.05, 0.5, and 5 mM); sulfate
(0.09, 0.9, and 9 mM); iodide (0.05, 0.5, and 5 mM); acetate (0.05,
0.5, and 5 mM); carbonate (0.05, 0.5, and 5 mM); and humic acid (5,
0.5, and 0.25 mM).
Current–time response
profile of the class="Chemical">phosphate sensor. (a)
Chronoamclass="Chemical">perograms showing the class="Chemical">pan class="Chemical">phosphate sensor response at different
phosphateconcentrations. (b) Phosphate sensor calibration curve showing
a linear range of detection from 5 × 10–7 to
5 × 10–4 M with bulk cobalt wire. The current
signal obtained from the buffer was subtracted from all sample peak
currents. The intra-assay coefficient of the variation percentage
(CV%) (n = 8) was calculated to be 4.4%. (c) Evaluation
of cobalt sensor response in the pH range of 2 to 8. Square wave pulsed
voltammograms show the characteristic cathodic current of 10–4 M aqueous KH2PO4 at various pH ranges from
2 to 8 in a 25 mM KHP buffer and 1 mM KCl at a scan rate of 50 mV/s.
(d) Evaluation of the effect of dissolved oxygen on the cobalt phosphate
sensor. Inset: Difference in current response measured at the cathodic
peak potential (−1.05 V). (e) Evaluation of the electrochemical
stability of the cobalt-based phosphate sensor at a fixed phosphateconcentration (∼10–5 M). Inset: Variation
in the current response measured at the cathodic peak potential (−1.05
V) for 10 measurements. (f) Evaluation of the cobalt sensor response
in the presence of various interfering cations. The bar graph shows
the change in the current response measured at the cathodic peak potential
(−1.05 V). Left to right: nitrate (0.05, 0.5, and 5 mM); sulfate
(0.09, 0.9, and 9 mM); iodide (0.05, 0.5, and 5 mM); acetate (0.05,
0.5, and 5 mM); carbonate (0.05, 0.5, and 5 mM); and humic acid (5,
0.5, and 0.25 mM).
Effect
of Environmental Interferences and
Electrochemical Stability
To check the class="Chemical">cobalt sensor’s
selectivity in detecting class="Chemical">pan class="Chemical">phosphate ions and evaluating the influence
of other interfering factors on the performance of the phosphate sensor,
the following tests were performed.
Effect
of pH on the Phosphate Sensor
The thermodynamic equilibrium
state of the class="Chemical">metal–electrolyte
system at varying class="Chemical">pHs in an electrochemical system can be investigated
using the Pourbaix diagram. Suclass="Chemical">pclass="Chemical">plementary Information Figure S3 shows the Pourbaix diagram of class="Chemical">pan class="Chemical">cobalt.
The cathodic (orange bullets) and anodic (blue bullets) peak potential
obtained from the CV curve at pH = 2 to 11 was plotted on the Pourbaix
diagram. The corresponding square wave pulsed voltammograms showing
the characteristic cathodic current curves at different pH conditions
are also presented in Figure c. The corresponding CV curves are shown in Supplementary
Information Figure S5. The
plots from the Pourbaix diagram and the CV curves suggest that the
sensor response is pH-dependent. The availability of nutrient phosphate
is significantly affected by the pH condition of the water.[42,43] The ideal pH condition for most algae growth falls slightly within
the alkaline pH range of 8.2 to 8.7.[44] However,
certain algae species, for example, Spirodela polyrrhiza, grow at a slightly acidic pH between 6 and 6.5.[45] As a result, for this project, we have recorded
the response of the electrochemical phosphate sensor over a broad
pH range.
Effect of Dissolved Oxygen
on the Phosphate
Sensor
Dissolved class="Chemical">oxygen (class="Chemical">pan class="Chemical">DO) is known to steadily deplete
in areas rich in microalgal bacterial flocs.[46] To closely mimic the environmental settings and confirm the stability
of the cobalt-based phosphate sensor under such conditions, we evaluated
the effect of DO on the electrode surface. Figure d shows three CV curves under the following
conditions: as-prepared, air/O2-saturated (increase in
DO), and N2-purged (decrease in DO) at a 10–2 M constant aqueous phosphateconcentration. The concentration of
DO, measured using a commercially available oxygen electrode (YSI,
USA), was found to be 7.94 ppm for as-prepared, 8.08 ppm for air/O2-saturated, and 2.02 ppm for N2-saturated phosphate
solutions. The response of the phosphate sensor was influenced by
the DOconcentration as assisted by the cathodic reduction peak observed
at around −1.05 V due to oxygen reduction reaction in eq below:
The current response
changed from −1.2 to −2.0 μA (∼66% change)
when the pan class="Chemical">DO changed from 2 to 8 class="Chemical">pclass="Chemical">pm (inset Figure d). This result suggests that class="Chemical">pan class="Chemical">DO needs to
be measured along with the sensor response for any practical application
as it will interfere with an analyte.
Electrochemical
Stability
In addition,
the electrochemical stability of the class="Chemical">cobalt sensor was evaluated by
reclass="Chemical">pan class="Chemical">cording the CV 10 times at the same 10–5 M phosphateconcentration, as shown in Figure e. The inset plot of the current vs the number of measurements
shows negligible variation, indicating the high stability of the cobalt
sensor.
Effect of Interfering Ions on the Phosphate
Sensor
The interfering ions (e.g., class="Chemical">nitrate, class="Chemical">pan class="Chemical">sulfate, acetate,
carbonate, and iodide) were selected because they are widely found
in various environmental samples (e.g., in river water) as well as
in drinking water.[47] These ions are generally
present at concentrations in the ∼10–3 to
10–5 M range.[48] The interference
of these ions on the sensor response was tested by measuring the CV
of the orthophosphate (H2PO4–) ions (∼1 mM) in the presence of five times the concentration
of the interfering ions (∼5 mM). The bar chart in Figure f shows the variation
in the phosphate sensor current response in the presence of various
interfering cations (evaluated at ∼−1.0 V cathodic peak
potential). These results showed a deviation of ±20% due to the
presence of interfering ions, with the highest effect being found
with the presence of humic acid (±15%) in the water sample. Other
ions have a moderate effect of ∼±5% on sensor performance,
supporting the selectivity of the cobalt-based phosphate sensor. The
shift in current response was quantified using eq :where Ip is the phosphate
current value and Iii is the interfering
ion current. Collectively, these results
show that the cobalt electrode exhibits good selectivity and sensitivity
for phosphate ions, strengthening the potential of the cobalt sensor
for biological and agricultural applications where the environmental
interferences mentioned previously are commonly observed.[27,49,50]
Surface
Characterization
To investigate
the class="Chemical">cobalt electrode surface chemistry under various class="Chemical">pan class="Chemical">conditions, we
conducted X-ray photoelectron spectroscopy (XPS) studies on the sensors
before and after the electrochemical experiments (Figure ). Deconvolution of the XPS
spectra for the fresh cobalt wire showed four orbital splitting peaks,
specifically, a Co0 (Co 2p3/2) prominent peak
at 778 eV, a CoO (Co 2p3/2) peak at 781 eV, and a Co 2p1/2 peak at 797 eV (Figure a (S1)). These values are in good agreement with data
found in the literature for Co 2p core-level XPS spectra.[51,52] After electrochemical experiments using different test solutions,
the deconvoluted XPS spectra showed only two prominent peaks as seen
in Figure a (S2–S4)
due to the oxidation of Co0 to Co2+. In a 25
mM KHP buffer (Figure a (S2)), a peak shift was observed from the oxidation of Co0 (Co 2p3/2 at 778 eV) to Co2+(Co 2p3/2 at 781.5 eV). Similar results were also observed in previous studies.[29,53] Similarly, for the cobalt electrodes exposed to phosphate ions (Figure a (S3)), a shift
in the peak in the XPS peaks was observed due to the oxidation of
Co0 (Co 2p3/2) at 778 eV to Co2+ (Co
2p3/2) at 782.5 eV due to the formation of the Co3(PO4)2complex on the electrode surface. Furthermore,
the appearance of the Co2+ (Co 2p3/2) peak at
783.5 eV is further evidence of the formation of the Co3(PO4)2complex after additional CV cycles (Figure a (S4)). Peaks for
carbon at 284 eV correspond to the C–C bonding and at 286 eV
to the C–O adventitious carbon peaks (Figure b). Peaks for oxygen were observed at 532
eV, specific to C–O bonding, and H–O–C stretching
was observed at 533 eV.
Figure 3
Deconvoluted XPS peaks of cobalt electrode.
(a) Peaks for cobalt
(Co), (b) peaks for carbon (C), and (c) peaks for oxygen (O). S1:
bare cobalt wire, S2: KHP buffer (after 10 cycles of CV), S3: KHP
buffer + KH2PO4 (after 10 cycles of CV), and
S4: KHP buffer + KH2PO4 (after 20 cycles of
CV).
Declass="Chemical">convoluted XPS class="Chemical">peaks of class="Chemical">pan class="Chemical">cobalt electrode.
(a) Peaks for cobalt
(Co), (b) peaks for carbon (C), and (c) peaks for oxygen (O). S1:
bare cobalt wire, S2: KHP buffer (after 10 cycles of CV), S3: KHP
buffer + KH2PO4 (after 10 cycles of CV), and
S4: KHP buffer + KH2PO4 (after 20 cycles of
CV).
To validate the XPS results and
support the evidence of the formation
of the class="Chemical">Co3(PO4)2class="Chemical">pan class="Chemical">complex, we collected
energy dispersive X-ray spectroscopy (EDAX) spectra of the cobalt
electrode under the same test conditions. The results are presented
in Supplementary Information Figure S4.
The EDAX results showed a decrease in the weight % for Co in the K-shell from 98.1 to 93.7% due to the oxidation of cobalt
observed in the XPS studies.
Surface Charge Transfer
Processes on a Cobalt
Electrode
The charge transfer processes occurring on the
class="Chemical">cobalt electrode surface due to the diffusion of the class="Chemical">pan class="Chemical">phosphate ions
were investigated using electrochemical impedance spectroscopy (EIS).
The impedimetric response of the cobalt sensor was measured as a function
of the phosphateconcentration in the frequency range of 1.0 Hz to
1.0 MHz with an AC amplitude of 10 mV vs Ag/AgCl. The semicircular
curve in EIS, referred to as the Nyquist curve, corresponds to the
electron transfer process, its diameter suggesting the electron/charge
transfer resistance (RCT) that depends
on the properties of the electrode–electrolyte interface.[54] The corresponding Nyquist curves at different
phosphate ion concentrations are shown in Figure . The inset of Figure a shows the equivalent circuit used to fit
the impedance data. Here, RS is the solution
resistance, CPE the constant phase element, ZW the Warburg impedance, and R(z) is the redox resistance that occurs due to the diffusion of the
phosphate ions from the bulk to the cobalt electrode interface.[55] The solution resistance (RS) for all experiments was found to be ∼100–200
Ω (Figure a).
The EIS results show an increase in RCT from 1 to 3.5 kΩ with an increase in phosphateconcentration
in the range of 0–500 μM (Figure b). The increase in the charge transfer resistance
results because of the formation of a Co3(PO4)2 dielectric layer with the increase in the concentration
of phosphate, a finding that agrees well with our proposed mechanism.
Figure 4
(a) Nyquist
curve at different phosphate ion concentrations in
the range of 0 to 500 μM. The inset shows the equivalent circuit.
(b) Plot of charge transfer resistance at different phosphate ion
concentrations.
(a) Nyquist
curve at different class="Chemical">phosphate ion class="Chemical">pan class="Chemical">concentrations in
the range of 0 to 500 μM. The inset shows the equivalent circuit.
(b) Plot of charge transfer resistance at different phosphate ion
concentrations.
Electrochemical
Phosphate Detection in Environmental
Water Samples
Our CV technique was used to detect class="Chemical">orthophosphate
in class="Chemical">pan class="Chemical">water samples from the Mississippi River. This test had two objectives:
(i) to demonstrate whether the calibration curve developed for the
electrochemical sensor is appropriate for on-field application and
(ii) to assess the interferences from the real water matrix on phosphate
ion detection. The CV measurements from 14 water samples collected
over a one-month period are presented in Figure a. The unknown phosphateconcentrations in
the Mississippi River water samples were determined from the calibration
curve developed by using the reduction peak current (at −1.05
V). The results have also been tabulated in Supplementary Information Table S1. These results were validated
using EPA Method 365.5.
Figure 5
Phosphate detection in Mississippi (MS) water
samples. (a) Electrochemical
detection method. Cyclic voltammograms of cobalt wire as the working
electrode with an Ag/AgCl reference electrode and Pt wire as a counter
electrode in a 25 mM KHP buffer and a 1 mM KCl with KH2PO4; pH ∼ 4.2. (b) Photometric detection method.
Absorbance recorded from a flow injection system at (i) 0, (ii) 0.1,
(iii) 0.25, (iv) 0.75, (v) 2, (vi) 5, and (vii) 10 μM phosphate
concentrations. Inset: Calibration curve obtained by the signals recorded
from the flow injection analysis (n = 2). (c) Performance
comparison of electrochemical versus photometric phosphate concentration.
class="Chemical">Phosphate detection in Mississiclass="Chemical">pclass="Chemical">pi (MS) class="Chemical">pan class="Chemical">water
samples. (a) Electrochemical
detection method. Cyclic voltammograms of cobalt wire as the working
electrode with an Ag/AgCl reference electrode and Pt wire as a counter
electrode in a 25 mM KHP buffer and a 1 mM KCl with KH2PO4; pH ∼ 4.2. (b) Photometric detection method.
Absorbance recorded from a flow injection system at (i) 0, (ii) 0.1,
(iii) 0.25, (iv) 0.75, (v) 2, (vi) 5, and (vii) 10 μM phosphateconcentrations. Inset: Calibration curve obtained by the signals recorded
from the flow injection analysis (n = 2). (c) Performance
comparison of electrochemical versus photometric phosphateconcentration.
Spectrophotometric Phosphate
Detection in
Environmental Water Samples
To validate our results from
the electrochemical measurements, the EPA standard spectrophotometric
method was used to determine the class="Chemical">phosphateclass="Chemical">pan class="Chemical">content in the river water
samples. The phosphate signals recorded from the flow injection system
from 0 to 10 μM phosphateconcentrations using the spectrophotometric
method can be seen in Figure b. The phosphateconcentrations for the Mississippi River
water samples determined from the calibration curve are presented
in Figure b (inset),
and the results are tabulated in Supplementary Information Table S2. The performance comparison of the electrochemical
versus the photometric phosphateconcentration is presented in Figure c. The Pearson’s R, determined from the statistical analysis of the data
presented in Figure c, was found to be 0.889, indicating a good fit of the electrochemical
and photometric phosphateconcentration. These results
indicate that the cobalt–phosphate sensor exhibits good performance
and stability for applications related to the real water matrix.
Disposable Microfabricated Phosphate Sensor
Chips
For field applications, we designed, fabricated, and
tested disposable sensors on a glass substrate. Figure a,b show the oclass="Chemical">ptical images of the fabricated
sensors. For simclass="Chemical">plicity and low class="Chemical">pan class="Chemical">cost, we used Au as both the reference
and counter electrode, and a planar cobalt electrode was used as a
working electrode. This design is also compatible with large-scale
production using screen-printing technology. The electrochemical response
of this fully integrated sensor was evaluated using CV testing. The
CV curves in Figure c (and Supplementary Information Figure S8) show the phosphate selective response of these disposable sensors
over dynamic concentrations ranging from 10–10 to
10–2 M. The applied potential was in the voltage
range of −1.4 to 0.4 V. Due to the use of Au as the reference
electrode, the cathodic dip due to the reduction of Co2+ to Co0 on our sensor shifted from the previously described
position and appeared at about −1.0 V. These results are in
accordance with the reduction peak observed in Figure c at −1.0 V with our optimized cobalt-based
phosphate sensor. The anodic peak also increased with the increase
in the phosphateconcentrations, similar to the results observed with
the bulk Co electrodes. The phosphate sensor calibration curve (provided
in the inset in Figure c) shows a linear trend from 10–10 to 10–2 M with a detection limit of ∼10–7 M (Supplementary
Information Table S4). The R2 coefficient of the linear fit was found to be 0.99.
We have obtained an order of magnitude improved limit of detection
in comparison to previously published reports using a cobalt sensor
(Supplementary Information Table S5). The
disposable sensor also exhibited significant reproducibility with
a chip-to-chip variation of 0.03%. Additionally, Aumetal deposition
is easy and corrosion-resistant and does not easily oxidize, ensuring
long-term stability for mass production. The performance of the glass-printed
cobalt–phosphate sensor was found to be better compared to
the conventional bulk Co wire. Furthermore, the printed sensor can
be integrated with a point-of-application device, making this sensor
chip applicable for portable on-field environmental applications.
Figure 6
Printed
electrodes on the glass substrate. (a–b) Image showing
the sensor. Here, C = counter electrode, R = reference electrode,
and W = working electrode. (c) Phosphate sensing using the printed
electrodes. Cyclic voltammograms of Co-metal as the working electrode
with Au-metal as the reference and counter electrode in a 25 mM KHP
buffer and 1 mM KCl with KH2PO4 in the concentration
range of 10–10 to 10–2 M at a
scan rate of 50 mV/s. Inset: Phosphate sensor calibration curve showing
a linear range of detection in 10–10 to 10–2 M. Note: The current signal obtained from the buffer was subtracted
from all sample peak currents.
Printed
electrodes on the glass substrate. (a–b) Image showing
the sensor. Here, C = class="Chemical">counter electrode, R = reference electrode,
and W = worclass="Chemical">pan class="Chemical">king electrode. (c) Phosphate sensing using the printed
electrodes. Cyclic voltammograms of Co-metal as the working electrode
with Au-metal as the reference and counter electrode in a 25 mM KHP
buffer and 1 mM KCl with KH2PO4 in the concentration
range of 10–10 to 10–2 M at a
scan rate of 50 mV/s. Inset: Phosphate sensor calibration curve showing
a linear range of detection in 10–10 to 10–2 M. Note: The current signal obtained from the buffer was subtracted
from all sample peak currents.
Conclusions
Portable devices are needed for
on-field applications to monitor
class="Chemical">waterclass="Chemical">pollutants to helclass="Chemical">p alleviate class="Chemical">pan class="Chemical">water contamination problems. We
report the design, fabrication, and testing of a low-cost, portable,
and sensitive electrochemical Co-based sensor for the quantitative
determination of phosphate. The bulk sensor showed a linear response
for phosphate ions within a dynamic range of 10–7 to 10–3 M. The limit of detection of the bulk
sensor was found to be 10–7 M. The sensor performance
was influenced by DO and pH interferences. Furthermore, humic acid
exhibited the greatest effect on phosphate sensor performance. The
results suggest that simultaneous measurement of DO and pH is needed
for accurate estimation and successful implementation for on-field
environmental application.
Experimental Section
Materials
class="Chemical">Potassium phosphate (class="Chemical">pan class="Chemical">KH2PO4) and potassium hydrogen phthalate (KHP) were
purchased from Ward Science (Rochester, NY, USA). Potassium chloride
(KCl), sodium carbonate (Na2CO3), potassium
iodide (KI), sodium nitrate (NaNO3), and calcium acetate
(C4H6O4Ca) were ordered from VWR-Chemicals
(Missouri, TX, USA). Potassium sulfate (K2SO4) was acquired from EMD Chemicals (Burlington, MA, USA). Cobalt wire
(0.5 mm diameter, 99.995% pure) and humic acid were purchased from
Alfa Aesar (Ward Hill, MA, USA). The double-distilled water obtained
from Milli-Q was utilized for making solutions of all analytes.
Electrochemical Measurements
An electrochemical
workstation (Potentiostat/Galvanostat Interface1010E, Gamry Instruments,
Warminster, PA, USA) was employed to reclass="Chemical">cord the cyclic voltammograms
(CV) and the chronoamclass="Chemical">perometry (CA) resclass="Chemical">ponse. Initial class="Chemical">pan class="Chemical">phosphate sensing
was demonstrated using a three-electrode (working, counter, and reference
electrode) configuration, with a Co wire (diameter = 0.5 mm, active
area ∼ 1.85 cm2) serving as a working electrode,
Pt wire as a counter electrode, and Ag/AgCl as a reference electrode.
A scanning rate of 50 mV/s was used for all CV measurements, and
the applied potential was scanned for four cycles in the voltage range
of −1.4 to 0.4 V in a 25 mM class="Chemical">KHP buffer and 1 mM class="Chemical">pan class="Chemical">KCl with KH2PO4 in a concentration range of 5 × 10–7 to 5 × 10–4 M at pH ∼
4.2. The sensor calibration curve and the limit of detection were
evaluated for these concentration ranges. The CA measurements were
performed in the same concentration range while applying a step potential
of 0.25 V with a timestep of 40 s. Square wave pulsed voltammetry
(SQV) experiments were conducted using the same setup within a potential
window from 0.4 to −1.4 V vs Ag/AgCl using a 50 mV amplitude,
a potential step of 0.75 mV, and a frequency of 25 Hz.
The sensing
performance of the electrodes was evaluated by class="Chemical">conducting
voltammetry exclass="Chemical">periments under various class="Chemical">pan class="Chemical">conditions including (i) the
effect of dissolved oxygen, (ii) the effect of pH, and (iii) the effect
of common interfering ions normally present in environmentalwater
samples. The effect of dissolved oxygen was evaluated by recording
and comparing CV measurements at the same aqueous phosphateconcentration
as prepared after air/O2 saturation through bubbling air
for ∼30 min and after N2 saturation by bubbling
high-purity N2 for up to ∼30 min. The concentrations
of oxygen in the test solutions were monitored using a commercial
oxygen electrode. The solutions post-bubbling were immediately used
for conducting CV measurements under identical experimental settings.
The influence of pH was evaluated using CV and SQV in the pH range
from 2 to 11 by adjusting to the desired pH using diluteHCl (1 M)
and/or NaOH (0.75 M). The effect of interference from common ions,
specifically sulfate, carbonate, acetate, nitrate, and iodide, was
recorded at different concentrations. We also evaluated the effect
of natural organic matters or humic acid on the phosphate measurements.
Further electrochemical class="Chemical">phosphate measurements were class="Chemical">pan class="Chemical">conducted using
river water samples collected from the Mississippi River at Baton
Rouge, Louisiana, every other day over a period of 30 days. The samples
were stored at 4 °C for further analysis. From the collected
river water samples, 10 mL of the water samples was filtered through
a 0.2 μm syringe filter before each experiment. For the electrochemical
experiments, the pH of the samples was brought to pH ∼ 4.2
by adding 25 mM KHP. Finally, the CV and CA responses were recorded
as described above.
Characterization
An X-ray photoelectron
spectrosclass="Chemical">coclass="Chemical">pe (XPS) from Scienta Omicron ESCA 2SR with an Al Kα
X-ray source was used for class="Chemical">pan class="Chemical">cobalt electrode surface examination. The
XPS spectra were obtained from an inert environment by applying 3
keV beam energy at a 45° inclination to etch the cobalt surface.
Spectrophotometry Measurements
For
validating the electrochemical results, EPA Method 365.5 (class="Chemical">orthophosphate
in class="Chemical">pan class="Chemical">estuarine and coastal water by colorimetry) was used to determine
the phosphatecontent in the Mississippi River water samples. An OI
Analytical Flow Solutions IV auto analyzer was used for the colorimetric
determination of phosphate. Briefly, the spectrophotometric determination
of orthophosphate was based on the reaction of the water sample with
a composite reagent of ammonium molybdate ((NH4)2MoO4) and antimony potassium tartarate (C8H10K2O15Sb2) in an acidic medium
to form an antimony phosphomolybdatecomplex. The resulting complex
reacted with ascorbic acid to produce a bluish complex, the optical
absorbance of which was measured at ∼660 nm. The color intensity
of the resulting sample is directly proportionate to the orthophosphateconcentration.
Fabrication of Printed
Electrodes
For the fabrication of printed electrodes (with
worclass="Chemical">king, class="Chemical">pan class="Chemical">counter,
and reference electrodes), a design was made using AutoCAD 2016 with
dimensions suitable for a standard glass slide (75 × 25 mm).
This design was cut from a clear Mylar sheet using a Cameo Cutter,
and the cut pieces were taped on a standard clean glass slide for
metal deposition using vacuum tape. A Physical Vapor Deposition Evaporator
at a base pressure of 10–8 Torr was used for the
deposition of the metals. Briefly, a Ti layer of 35 nm was deposited
at 20 Å/s (for working, counter, and reference electrodes) followed
by a 200 nm Au layer deposited at 1 Å/s to create the counter
and reference electrodes by masking the working electrode with a Mylar
sheet. Finally, a Co layer of 300 nm was deposited at 1–5 Å/s
to create the working electrode by masking the remaining areas with
a Mylar sheet. The size of the sensing area was 8.9 mm2, and the gap between each electrode was 0.35 mm. The area of the
working electrode was 2.8 mm2, the area of the counter
electrode was 6.0 mm2, and the area of the reference electrode
was 0.73 mm2. The detailed fabrication procedure with photographs
is shown in the Supplementary Information.
Authors: François-Eric Legiret; Vincent J Sieben; E Malcolm S Woodward; Samer K Abi Kaed Bey; Matthew C Mowlem; Douglas P Connelly; Eric P Achterberg Journal: Talanta Date: 2013-05-09 Impact factor: 6.057