Radiation induced currents in MRI RF coils: application to linac/MRI integration.

B Burke1, B G Fallone, S Rathee.   

Abstract

The integration of medical linear accelerators (linac) with magnetic resonance imaging (MRI) systems is advancing the current state of image-guided radiotherapy. The MRI in these integrated units will provide real-time, accurate tumor locations for radiotherapy treatment, thus decreasing geometric margins around tumors and reducing normal tissue damage. In the real-time operation of these integrated systems, the radiofrequency (RF) coils of MRI will be irradiated with radiation pulses from the linac. The effect of pulsed radiation on MRI radio frequency (RF) coils is not known and must be studied. The instantaneous radiation induced current (RIC) in two different MRI RF coils were measured and presented. The frequency spectra of the induced currents were calculated. Some basic characterization of the RIC was also done: isolation of the RF coil component responsible for RIC, dependence of RIC on dose rate, and effect of wax buildup placed on coil on RIC. Both the time and frequency characteristics of the RIC were seen to vary with the MRI RF coil used. The copper windings of the RF coils were isolated as the main source of RIC. A linear dependence on dose rate was seen. The RIC was decreased with wax buildup, suggesting an electronic disequilibrium as the cause of RIC. This study shows a measurable RIC present in MRI RF coils. This unwanted current could be possibly detrimental to the signal to noise ratio in MRI and produce image artifacts.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20071754      PMCID: PMC2910755          DOI: 10.1088/0031-9155/55/3/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  Currents induced in the dielectrics of fonization chambers through the action of highenergy radiation.

Authors:  H E JOHNS; N ASPIN; R G BAKER
Journal:  Radiat Res       Date:  1958-12       Impact factor: 2.841

Review 2.  Advances in image-guided radiation therapy.

Authors:  Laura A Dawson; David A Jaffray
Journal:  J Clin Oncol       Date:  2007-03-10       Impact factor: 44.544

Review 3.  Innovations in image-guided radiotherapy.

Authors:  Dirk Verellen; Mark De Ridder; Nadine Linthout; Koen Tournel; Guy Soete; Guy Storme
Journal:  Nat Rev Cancer       Date:  2007-12       Impact factor: 60.716

4.  Magnetic-field-induced dose effects in MR-guided radiotherapy systems: dependence on the magnetic field strength.

Authors:  A J E Raaijmakers; B W Raaymakers; J J W Lagendijk
Journal:  Phys Med Biol       Date:  2008-01-18       Impact factor: 3.609

5.  Integrating a 1.5 T MRI scanner with a 6 MV accelerator: proof of concept.

Authors:  B W Raaymakers; J J W Lagendijk; J Overweg; J G M Kok; A J E Raaijmakers; E M Kerkhof; R W van der Put; I Meijsing; S P M Crijns; F Benedosso; M van Vulpen; C H W de Graaff; J Allen; K J Brown
Journal:  Phys Med Biol       Date:  2009-05-19       Impact factor: 3.609

6.  Radio frequency noise from clinical linear accelerators.

Authors:  B Burke; M Lamey; S Rathee; B Murray; B G Fallone
Journal:  Phys Med Biol       Date:  2009-04-01       Impact factor: 3.609

7.  First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system.

Authors:  B G Fallone; B Murray; S Rathee; T Stanescu; S Steciw; S Vidakovic; E Blosser; D Tymofichuk
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

8.  Radiation induced currents in parallel plate ionization chambers: measurement and Monte Carlo simulation for megavoltage photon and electron beams.

Authors:  Wamied Abdel-Rahman; Jan P Seuntjens; Frank Verhaegen; Ervin B Podgorsak
Journal:  Med Phys       Date:  2006-09       Impact factor: 4.071

9.  Patient dosimetry for hybrid MRI-radiotherapy systems.

Authors:  C Kirkby; T Stanescu; S Rathee; M Carlone; B Murray; B G Fallone
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

  9 in total
  1 in total

1.  Quantitative analysis of image quality for acceptance and commissioning of an MRI simulator with a semiautomatic method.

Authors:  Xinyuan Chen; Jianrong Dai
Journal:  J Appl Clin Med Phys       Date:  2018-03-24       Impact factor: 2.102

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.