Literature DB >> 18263948

Magnetic-field-induced dose effects in MR-guided radiotherapy systems: dependence on the magnetic field strength.

A J E Raaijmakers1, B W Raaymakers, J J W Lagendijk.   

Abstract

Several institutes are currently working on the development of a radiotherapy treatment system with online MR imaging (MRI) modality. The main difference between their designs is the magnetic field strength of the MRI system. While we have chosen a 1.5 Tesla (T) magnetic field strength, the Cross Cancer Institute in Edmonton will be using a 0.2 T MRI scanner and the company Viewray aims to use 0.3 T. The magnetic field strength will affect the severity of magnetic field dose effects, such as the electron return effect (ERE): considerable dose increase at tissue air boundaries due to returning electrons. This paper has investigated how the ERE dose increase depends on the magnetic field strength. Therefore, four situations where the ERE occurs have been simulated: ERE at the distal side of the beam, the lateral ERE, ERE in cylindrical air cavities and ERE in the lungs. The magnetic field comparison values were 0.2, 0.75, 1.5 and 3 T. Results show that, in general, magnetic field dose effects are reduced at lower magnetic field strengths. At the distal side, the ERE dose increase is largest for B = 0.75 T and depends on the irradiation field size for B = 0.2 T. The lateral ERE is strongest for B = 3 T but shows no effect for B = 0.2 T. Around cylindrical air cavities, dose inhomogeneities disappear if the radius of the cavity becomes small relative to the in-air radius of the secondary electron trajectories. At larger cavities (r > 1 cm), dose inhomogeneities exist for all magnetic field strengths. In water-lung-water phantoms, the ERE dose increase takes place at the water-lung transition and the dose decreases at the lung-water transition, but these effects are minimal for B = 0.2 T. These results will contribute to evaluating the trade-off between magnetic field dose effects and image quality of MR-guided radiotherapy systems.

Entities:  

Mesh:

Year:  2008        PMID: 18263948     DOI: 10.1088/0031-9155/53/4/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  43 in total

Review 1.  Individualized radiotherapy by combining high-end irradiation and magnetic resonance imaging.

Authors:  Stephanie E Combs; Fridtjof Nüsslin; Jan J Wilkens
Journal:  Strahlenther Onkol       Date:  2016-02-06       Impact factor: 3.621

2.  Monte Carlo simulations of patient dose perturbations in rotational-type radiotherapy due to a transverse magnetic field: a tomotherapy investigation.

Authors:  Y M Yang; M Geurts; J B Smilowitz; E Sterpin; B P Bednarz
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

3.  Feasibility of spinal stereotactic body radiotherapy in Elekta Unity® MR-Linac.

Authors:  Eun Young Han; Manik Aima; Neil Hughes; Tina M Briere; Debra N Yeboa; Pam Castillo; Jihong Wang; Jinzhong Yang; Sastry Vedam
Journal:  J Radiosurg SBRT       Date:  2020

4.  New concept on an integrated interior magnetic resonance imaging and medical linear accelerator system for radiation therapy.

Authors:  Xun Jia; Zhen Tian; Yan Xi; Steve B Jiang; Ge Wang
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-02

Review 5.  Magnetic resonance image guidance in external beam radiation therapy planning and delivery.

Authors:  Ilamurugu Arivarasan; Chandrasekaran Anuradha; Shanmuga Subramanian; Ayyalusamy Anantharaman; Velayudham Ramasubramanian
Journal:  Jpn J Radiol       Date:  2017-06-13       Impact factor: 2.374

Review 6.  Biological effects of static magnetic field exposure in the context of MR-guided radiotherapy.

Authors:  Jonathan Kim Mohajer; Andrew Nisbet; Eirini Velliou; Mazhar Ajaz; Giuseppe Schettino
Journal:  Br J Radiol       Date:  2018-10-31       Impact factor: 3.039

7.  Feasibility of normal tissue dose reduction in radiotherapy using low strength magnetic field.

Authors:  Nuri Hyun Jung; Youngseob Shin; In-Hye Jung; Jungwon Kwak
Journal:  Radiat Oncol J       Date:  2015-09-30

Review 8.  Magnetic resonance imaging in precision radiation therapy for lung cancer.

Authors:  Hannah Bainbridge; Ahmed Salem; Rob H N Tijssen; Michael Dubec; Andreas Wetscherek; Corinne Van Es; Jose Belderbos; Corinne Faivre-Finn; Fiona McDonald
Journal:  Transl Lung Cancer Res       Date:  2017-12

9.  Monte Carlo study of the chamber-phantom air gap effect in a magnetic field.

Authors:  Daniel J O'Brien; Gabriel O Sawakuchi
Journal:  Med Phys       Date:  2017-05-26       Impact factor: 4.071

10.  Radiation induced currents in MRI RF coils: application to linac/MRI integration.

Authors:  B Burke; B G Fallone; S Rathee
Journal:  Phys Med Biol       Date:  2010-01-13       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.