Literature DB >> 20049481

Comparison of gas exchange data using the Aquatrainer system and the facemask with Cosmed K4b2 during exercise in healthy subjects.

Mathieu Gayda1, Laurent Bosquet, Martin Juneau, Thibaut Guiraud, Jean Lambert, Anil Nigam.   

Abstract

The aim of this study was to determine the level of agreement between the new Aquatrainer system and the facemask in the assessment of submaximal and maximal cardiopulmonary responses during exercise performed on ergocycle. Twenty-six physically active healthy subjects (mean age: 41 +/- 14 years) performed a submaximal constant work test followed by maximal incremental exercise test on ergocycle, one with cardiopulmonary responses measured using the Cosmed K4b2 facemask, the other using the Cosmed K4b2 Aquatrainer. Using the Aquatrainer, the gas exchange variables at 100 W were significantly lower for VO(2) (1,483 +/- 203 vs. 1,876 +/- 204 ml min(-1), P < 0.0001), VCO(2) (1,442 +/- 263 vs. 1,749 +/- 231 ml min(-1), P < 0.0001), VE (38 +/- 5 vs. 44 +/- 6 l min(-1), P < 0.0001), and VT (1.92 +/- 0.47 vs. 2.18 +/- 0.41 l, P < 0.0001) relative to facemask. The bias +/-95% limits of agreement (LOA) for VO(2) was 393 +/- 507 ml min(-1) for the submaximal constant work test at 100 W and 495 +/- 727 ml min(-1) for VO(2max). At maximal intensity, cardiopulmonary responses measured with the Aquatrainer system were significantly lower for: VO(2) (2,799 +/- 751 vs. 3,294 +/- 821 ml min(-1), P < 0.0001), VCO(2) (3,426 +/- 836 vs. 3,641 +/- 946 ml min(-1), P = 0.012), VE (98 +/- 21 vs. 108 +/- 26 l min(-1), P = 0.0009) relative to facemask. A non-constant measurement error [interaction effect: (facemask or aquatrainer) x power] was noted from 60 to 270 W for VO(2) (ml min(-1)), VCO(2) (ml min(-1)), ventilation (l min(-1)) (P < 0.0001) and VT (l, P = 0.0001). Additional studies are required to detect the main sources of error that could be physical and/or physiological in nature. Due to the significant measurement error, the new Aquatrainer system should be used with extreme caution in filed testing conditions of swimmers.

Entities:  

Mesh:

Year:  2010        PMID: 20049481     DOI: 10.1007/s00421-009-1312-2

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  31 in total

1.  Validation of the COSMED K4 b2 portable metabolic system.

Authors:  J E McLaughlin; G A King; E T Howley; D R Bassett; B E Ainsworth
Journal:  Int J Sports Med       Date:  2001-05       Impact factor: 3.118

Review 2.  Ambulatory gas exchange measurements--current status and future options.

Authors:  T Meyer; R C R Davison; W Kindermann
Journal:  Int J Sports Med       Date:  2005-02       Impact factor: 3.118

3.  Validity of a swimming snorkel for metabolic testing.

Authors:  F A Rodríguez; K L Keskinen; M Kusch; U Hoffmann
Journal:  Int J Sports Med       Date:  2007-10-24       Impact factor: 3.118

4.  Energetics of swimming in man.

Authors:  P E Di Prampero; D R Pendergast; D W Wilson; D W Rennie
Journal:  J Appl Physiol       Date:  1974-07       Impact factor: 3.531

5.  Effects of increased external airway resistance during steady-state exercise.

Authors:  M Demedts; N R Anthonisen
Journal:  J Appl Physiol       Date:  1973-09       Impact factor: 3.531

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Evaluation of the Cosmed K2 portable telemetric oxygen uptake analyzer.

Authors:  C G Crandall; S L Taylor; P B Raven
Journal:  Med Sci Sports Exerc       Date:  1994-01       Impact factor: 5.411

8.  Field testing of VO2peak in cross-country skiers with portable breath-by-breath system.

Authors:  K H Doyon; S Perrey; D Abe; R L Hughson
Journal:  Can J Appl Physiol       Date:  2001-02

9.  Accuracy and reliability of a Cosmed K4b2 portable gas analysis system.

Authors:  R Duffield; B Dawson; H C Pinnington; P Wong
Journal:  J Sci Med Sport       Date:  2004-03       Impact factor: 4.319

10.  VO2max, protocol duration, and the VO2 plateau.

Authors:  Byung-Kon Yoon; Len Kravitz; Robert Robergs
Journal:  Med Sci Sports Exerc       Date:  2007-07       Impact factor: 5.411

View more
  9 in total

1.  Letter to the editor of EJAP. Re: Comparison of gas exchange data using the Aquatrainer® system and the facemask with Cosmed K4b2 during exercise in healthy subjects.

Authors:  Paolo Brugnoli
Journal:  Eur J Appl Physiol       Date:  2010-06-18       Impact factor: 3.078

2.  Response to the letter of M. Brugnoli.

Authors:  Mathieu Gayda
Journal:  Eur J Appl Physiol       Date:  2010-10-22       Impact factor: 3.078

3.  VO₂ underestimation using the Aquatrainer compared with facemask measurements: is it all in the ventilation?

Authors:  Victor Machado Reis
Journal:  Eur J Appl Physiol       Date:  2010-11-17       Impact factor: 3.078

4.  Effects of aerobic fitness on oxygen uptake kinetics in heavy intensity swimming.

Authors:  Joana F Reis; Francisco B Alves; Paula M Bruno; Veronica Vleck; Gregoire P Millet
Journal:  Eur J Appl Physiol       Date:  2011-08-31       Impact factor: 3.078

5.  The effect of additional dead space on respiratory exchange ratio and carbon dioxide production due to training.

Authors:  Lukasz Smolka; Jacek Borkowski; Marek Zaton
Journal:  J Sports Sci Med       Date:  2014-01-20       Impact factor: 2.988

6.  Comparison of the metabolic energy cost of overground and treadmill walking in older adults.

Authors:  Nicolas Berryman; Mathieu Gayda; Anil Nigam; Martin Juneau; Louis Bherer; Laurent Bosquet
Journal:  Eur J Appl Physiol       Date:  2011-08-24       Impact factor: 3.078

7.  Reproducibility of an aerobic endurance test for nonexpert swimmers.

Authors:  Adalberto Veronese da Costa; Manoel da Cunha Costa; Daniel Medeiros Carlos; Luis Marcos de Medeiros Guerra; Antônio José Silva; Tiago Manoel Cabral Dos Santos Barbosa
Journal:  J Multidiscip Healthc       Date:  2012-09-06

8.  Cognitive function in patients with stable coronary heart disease: Related cerebrovascular and cardiovascular responses.

Authors:  Mathieu Gayda; Vincent Gremeaux; Louis Bherer; Martin Juneau; Joffrey Drigny; Olivier Dupuy; Gabriel Lapierre; Véronique Labelle; Annik Fortier; Anil Nigam
Journal:  PLoS One       Date:  2017-09-22       Impact factor: 3.240

9.  Validation of an equation for estimating maximal oxygen consumption of nonexpert adult swimmers.

Authors:  Adalberto Veronese da Costa; Manoel da Cunha Costa; Saulo Fernandes Melo de Oliveira; Fabíola Lima de Albuquerque; Fernando José de Sá Pereira Guimarães; Tiago Manuel Barbosa
Journal:  Open Access J Sports Med       Date:  2013-01-21
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.