| Literature DB >> 20042124 |
Maia Dzhugashvili1, Elodie Tournay, Charlotte Pichenot, Ariane Dunant, Eduardo Pessoa, Adel Khallel, Sébastien Gouy, Catherine Uzan, Jean-Rémy Garbay, Françoise Rimareix, Marc Spielmann, Philippe Vielh, Hugo Marsiglia, Céline Bourgier.
Abstract
BACKGROUND: Accurate localisation of the lumpectomy cavity (LC) volume is one of the most critical points in 3D-conformal Partial breast irradiation (3D-APBI) treatment planning because the irradiated volume is restricted to a small breast volume. Here, we studied the role of the placement of surgical clips at the 4 cardinal points of the lumpectomy cavity in target delineation.Entities:
Mesh:
Year: 2009 PMID: 20042124 PMCID: PMC2808304 DOI: 10.1186/1748-717X-4-70
Source DB: PubMed Journal: Radiat Oncol ISSN: 1748-717X Impact factor: 3.481
Figure 1Surgical procedure of clip placement.
Patient demographics and clinical data.
| N = 40 | Median | Min - max | N (%) |
|---|---|---|---|
| Age (years old) | 60 | 44 - 94 | |
| Tumour size (mm) | 12 | 2 - 35 | |
| Histological tumour volume (cm3) | 76 | 13 - 364 | |
| Time from surgery to radiotherapy (days) | 51 | 14 - 252 | |
| Adjuvant chemotherapy (number of patients) | 13 (33%) | ||
| pTis pN0 | 1 (2.5%) | ||
| pT1 pN0-1 | 33 (82.5%) | ||
| pT2 pN0-1 | 6 (15%) | ||
Discrepancies in lumpectomy cavity volumes between the 4 radiation oncologists (Juniors J1 and J2; Experts E1 and E2).
| N = 40 | Volume of lumpectomy cavity (cm3) | Volume of lumpectomy cavity (cm3) when the assessment was restricted to CT slices containing surgical clips | p | ||
|---|---|---|---|---|---|
| J1 | 14 | 5 - 53 | 15 | 6 - 53 | 0.98 |
| J2 | 16 | 5 - 61 | 16 | 5 - 60 | 0.39 |
| E1 | 13 | 5 - 48 | 12 | 5 - 46 | p < 0.0001 |
| E2 | 11 | 5 - 96 | 11 | 4 - 50 | p < 0.0001 |
Discrepancies in lumpectomy cavity (LC) volumes; in conformity index and in distances between centres of gravity of each LC volume when the study was restricted to CT slices containing surgical clips.
| Volume of lumpectomy cavity - cm3 (n = 40) | P* | Conformity index | Distance between gravity centres (mm) | ||
|---|---|---|---|---|---|
| ΔJ1-J2 | Med | - 0.9 | 0.02 | 0.64 | 2.2 |
| ΔJ1-E1 | Med | 1.5 | 0.007 | 0.65 | 1.8 |
| ΔJ1-E2 | Med | 3.5 | < 0.0001 | 0.57 | 2.4 |
| ΔJ2-E1 | Med | 3.5 | < 0.0001 | 0.57 | 2.4 |
| ΔJ2-E2 | Med | 4.2 | < 0.0001 | 0.55 | 3.1 |
| ΔE1-E2 | Med | 1.6 | < 0.0002 | 0.62 | 2.51 |
* p value for testing equality of volumes between physicians ( < 0.01 is significant).
ΔJ1-J2 = between J1 and J2. ΔJ1-E1 = between J1 and E1. ΔJ1-E2 = between J1 and E2. ΔJ2-E1 = between J2 and E1. ΔJ2-E1 = between J2 and E2. ΔE1-E2 = between E1 and E2.
Lumpectomy cavity (LC) volumes in APBI trials
| Median volume of lumpectomy cavity (cc) | Min - max (cc) | ||
|---|---|---|---|
| Berrang et al [ | Seroma visible on CT-scan | 31.8 | 7.3 - 131.9 |
| Seroma visible on 3D-US | 23.2 | 5 - 93.6 | |
| Ford et al [ | LC on CT scan | 15.4 | 5.2 - 133.5 |
| LC on PET-CT | 32.8 | 7 - 199.4 | |
| Vicini et al [ | LC | 12 | 5 - 65 |
| Formenti et al [ | LC | 34 | 7 - 379 |
| IGR study | LC by juniors | 14-16 | 5 - 61 |
| LC by experts | 11-13 | 5 - 96 | |
Discrepancies in distances inter-Com (Centre Of the Mass of the target volume) when the CTV was entirely assessed (study 1) and when the study was restricted to CT slices containing surgical clips (study 2).
| Study 1 | Study 2 | |||
|---|---|---|---|---|
| Median | Min - max | Median | Min - max | |
| ΔJ1-J2 | 3.4 | 0 - 11.9 | 2.2 | 0 - 11.9 |
| ΔJ1-E1 | 2.6 | 0.9 - 34.2 | 1.8 | 0.5 - 26.3 |
| ΔJ1-E2 | 3.3 | 1.1 - 36.5 | 2.4 | 0.6 - 30.9 |
| ΔJ2-E1 | 3.3 | 0.9 - 24.4 | 2.4 | 0.7 - 20.4 |
| ΔJ2-E2 | 3.5 | 1.3 - 26.2 | 3.1 | 1.3 - 24.7 |
| ΔE1-E2 | 3.1 | 0.2 - 24.3 | 2.5 | 0.2 - 10.0 |
ΔJ1-J2 = between J1 and J2. ΔJ1-E1 = between J1 and E1. ΔJ1-E2 = between J1 and E2. ΔJ2-E1 = between J2 and E1. ΔJ2-E1 = between J2 and E2. ΔE1-E2 = between E1 and E2.