Large ball metal on metal hips obscure cup angle measurement on plain radiographs.

Alister J Hart1, Wael Dandachli, Klaus Schlueter-Brust, Johann Henckel, Justin Cobb.   

Abstract

CT when compared to plain radiograph is known to be a more valid measure of acetabular component orientation. The validity of plain radiographs may be further compromised by large diameter metal femoral heads because of obscuration of the acetabular rim. We quantified this effect by measuring acetabular cup angles (inclination and version) of 49 metal on metal (MOM) hip resurfacings using plain radiographs and 3D CT based measurement. Bland-Altman plots revealed poor agreement between plain radiographic and CT based measurement with 2 standard deviation limits of agreements of: +7 to -15 degrees for cup inclination angle; and +16 to -31 degrees for cup version angle. The large differences between plain radiographic and CT measurement of cup positions are probably due to the large diameter metal femoral head that can obscure the cup margin. We have used a metal artefact reduction CT protocol with a 3D imaging software package to overcome this problem and measure cup position relative to the Anterior Pelvic Plane.

Entities:  

Mesh:

Year:  2009        PMID: 20041378     DOI: 10.1177/112070000901900405

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  6 in total

1.  Quantifying the contribution of pincer deformity to femoro-acetabular impingement using 3D computerised tomography.

Authors:  Wael Dandachli; Ali Najefi; Farhad Iranpour; Jonathan Lenihan; Alister Hart; Justin Cobb
Journal:  Skeletal Radiol       Date:  2012-03-17       Impact factor: 2.199

Review 2.  Revision total hip arthroplasty for metal-on-metal failure.

Authors:  Justin S Chang; Fares S Haddad
Journal:  J Clin Orthop Trauma       Date:  2019-10-04

3.  Insufficient acetabular version increases blood metal ion levels after metal-on-metal hip resurfacing.

Authors:  Alister J Hart; John A Skinner; Johann Henckel; Barry Sampson; Fabiana Gordon
Journal:  Clin Orthop Relat Res       Date:  2011-06-09       Impact factor: 4.176

4.  Pseudotumors are common in well-positioned low-wearing metal-on-metal hips.

Authors:  Ashley K Matthies; John A Skinner; Humza Osmani; Johann Henckel; Alister J Hart
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

5.  2D measurements of cup orientation are less reliable than 3D measurements.

Authors:  Kinner Davda; Niall Smyth; Justin P Cobb; Alister J Hart
Journal:  Acta Orthop       Date:  2015-02-12       Impact factor: 3.717

6.  Assessment of cup orientation in hip resurfacing: a comparison of TraumaCad and computed tomography.

Authors:  Daniel J Westacott; John McArthur; Richard J King; Pedro Foguet
Journal:  J Orthop Surg Res       Date:  2013-04-11       Impact factor: 2.359

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.