Etiology, risk factors and management of implant fractures.

Arturo Sánchez-Pérez1, Ma José Moya-Villaescusa, Alfonso Jornet-Garcia, Santiago Gomez.   

Abstract

Implant fracture is an infrequent and late biomechanical complication with a serious clinical outcome. In effect, such fractures pose important problems for both the patient and the dental surgeon. According to most literature sources, the prevalence of dental implant fractures is very low (approximately 2 fractures per 1000 implants in the mouth). Considering that implant placement is becoming increasingly popular, an increase in the number of failures due to late fractures is to be expected. Clearly, careful treatment can contribute to reduce the incidence of fracture. An early diagnosis of the signs alerting to implant fatigue, such as loosening, torsion or fracture of the post screws and prosthetic ceramic fracture, can help prevent an undesirable outcome. The present literature review describes the management options and discusses the possible causal mechanisms underlying such failures, as well as the factors believed to contribute to implant fracture.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20038899     DOI: 10.4317/medoral.15.e504

Source DB:  PubMed          Journal:  Med Oral Patol Oral Cir Bucal        ISSN: 1698-4447


  15 in total

1.  Influence of bone insertion level of the implant on the fracture strength of different connection designs: an in vitro study.

Authors:  Sergio Alexandre Gehrke; Miriam Souza Dos Santos Vianna; Berenice Anina Dedavid
Journal:  Clin Oral Investig       Date:  2013-07-17       Impact factor: 3.573

Review 2.  Dental implant fractures - aetiology, treatment and case report.

Authors:  Coelho Goiato Marcelo; Marcela Filié Haddad; Humberto Gennari Filho; Luiz Marcelo Ribeiro Villa; Daniela Micheline Dos Santos; Alves Pesqueira Aldiéris
Journal:  J Clin Diagn Res       Date:  2014-03-15

3.  Osteotomy combined with the trephine technique for invisible implant fracture: A case report.

Authors:  Liang-Wen Chen; Min Wang; Hai-Bin Xia; Dong Chen
Journal:  World J Clin Cases       Date:  2022-06-06       Impact factor: 1.534

4.  Dense cancellous bone as evidenced by a high HU value is predictive of late implant failure: a preliminary study.

Authors:  Ikuya Miyamoto; Tetsu Takahashi; Tatsurou Tanaka; Bunichi Hirayama; Kenko Tanaka; Toru Yamazaki; Yasuhiro Morimoto; Izumi Yoshioka
Journal:  Oral Radiol       Date:  2017-08-03       Impact factor: 1.852

5.  Prevalence of complications after the oral rehabilitation with implant-supported hybrid prostheses.

Authors:  Júlia Real-Osuna; Nieves Almendros-Marqués; Cosme Gay-Escoda
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-01-01

6.  Implant success lies in complications management: A report of two cases.

Authors:  Sapna Rani; Jyoti Devi; Mahesh Verma
Journal:  Contemp Clin Dent       Date:  2016 Apr-Jun

7.  Selectable Implant Removal Methods due to Mechanical and Biological Failures.

Authors:  Jong-Bin Lee
Journal:  Case Rep Dent       Date:  2017-07-05

8.  SEM Analysis and Management of Fracture Dental Implant.

Authors:  Archana Singh; Ankita Singh; Rajul Vivek; T P Chaturvedi; Pankaj Chauhan; Shruti Gupta
Journal:  Case Rep Dent       Date:  2013-04-23

Review 9.  Technical complications of implant-causes and management: A comprehensive review.

Authors:  Swati Gupta; Hemant Gupta; Amrit Tandan
Journal:  Natl J Maxillofac Surg       Date:  2015 Jan-Jun

Review 10.  Complications in implant dentistry.

Authors:  Ayesha Hanif; Saima Qureshi; Zeeshan Sheikh; Haroon Rashid
Journal:  Eur J Dent       Date:  2017 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.