Literature DB >> 20015806

Low-dose computed tomography of the paranasal sinuses: radiation doses and reliability analysis.

Kasim Abul-Kasim1, Anita Strömbeck, Pernilla Sahlstrand-Johnson.   

Abstract

PURPOSE: The study aimed to (1) optimize the radiation doses of computed tomography (CT) of paranasal sinuses, (2) compare the radiation doses of different CT protocols with that of plain radiography, and (3) evaluate the reliability of low-dose CT in the detection of pathology and characterization of the detected pathology.
MATERIALS AND METHODS: A head phantom was examined with different scan parameters to define a cutoff value to which the radiation dose can be reduced without negative impact on image quality. Kruskal-Wallis test and Wilcoxon W test were performed to compare the effective doses of the plain radiography in 30 patients with that of 3 different CT protocols in a total of 90 patients. The interobserver and intraobserver agreement in the detection of pathologic findings and in characterization of the pathology was estimated by calculating κ value.
RESULTS: The effective doses of plain radiography and low-dose CT were 0.098 and 0.045 mSv, respectively (P < .001). The effective dose of standard CT of sinuses (0.371 mSv) was 3.8 times higher than that of plain radiography and 8.2 times higher than that of low-dose CT (P < .001). The interobserver and intraobserver agreement on CT with regard to detection of pathology and pathology characterization was almost perfect (κ values 0.81-1) compared to fair (κ values 0.38-0.39) in plain radiography.
CONCLUSIONS: The here proposed low-dose CT means significant dose reduction and is a reliable method in the investigation of the paranasal sinuses.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 20015806     DOI: 10.1016/j.amjoto.2009.08.004

Source DB:  PubMed          Journal:  Am J Otolaryngol        ISSN: 0196-0709            Impact factor:   1.808


  10 in total

1.  Low-dose computed tomography of the paranasal sinus and facial skull using a high-pitch dual-source system--first clinical results.

Authors:  Boris Schell; Ralf W Bauer; Thomas Lehnert; J Matthias Kerl; Markus Hambek; Angelika May; Thomas J Vogl; Martin G Mack
Journal:  Eur Radiol       Date:  2010-07-20       Impact factor: 5.315

2.  Low-Dose CT of the Paranasal Sinuses: Minimizing X-Ray Exposure with Spectral Shaping.

Authors:  Wolfgang Wuest; Matthias May; Marc Saake; Michael Brand; Michael Uder; Michael Lell
Journal:  Eur Radiol       Date:  2016-02-24       Impact factor: 5.315

3.  Evaluation of different low-dose multidetector CT and cone beam CT protocols in maxillary sinus imaging: part I-an in vitro study.

Authors:  Abeer A Almashraqi; Eman A Ahmed; Nashwa S Mohamed; Imad H Barngkgei; Nader A Elsherbini; Esam S Halboub
Journal:  Dentomaxillofac Radiol       Date:  2017-04-12       Impact factor: 2.419

4.  Comparative assessment of panoramic radiography and CBCT imaging for radiodiagnostics in the posterior maxilla.

Authors:  Maryam Shahbazian; Charlotte Vandewoude; Jan Wyatt; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2013-03-24       Impact factor: 3.573

5.  Radiation dose reduction in paranasal sinus CT using model-based iterative reconstruction.

Authors:  J M Hoxworth; D Lal; G P Fletcher; A C Patel; M He; R G Paden; A K Hara
Journal:  AJNR Am J Neuroradiol       Date:  2013-10-10       Impact factor: 3.825

6.  [Significance of the sinus x-ray prior to septoplasty].

Authors:  F Bast; S Weikert; T Schrom
Journal:  HNO       Date:  2013-07       Impact factor: 1.284

7.  Reduction of Radiation Dosage in Visualization of Paranasal Sinuses in Daily Routine.

Authors:  Christian Güldner; Isabell Diogo; Julia Leicht; Magis Mandapathil; Thomas Wilhelm; Afshin Teymoortash; Evelyn Jahns
Journal:  Int J Otolaryngol       Date:  2017-01-31

8.  Tin-filtered 100 kV ultra-low-dose CT of the paranasal sinus: Initial clinical results.

Authors:  Bernhard Petritsch; Aleksander Kosmala; Andreas Max Weng; Thorsten Alexander Bley
Journal:  PLoS One       Date:  2019-05-06       Impact factor: 3.240

Review 9.  Dose reduction in CT imaging for facial bone trauma in adults: A narrative literature review.

Authors:  Tayla Hooper; Grace Eccles; Talia Milliken; Josephine R Mathieu-Burry; Warren Reed
Journal:  J Med Radiat Sci       Date:  2019-02-01

10.  Reducing the radiation dose of pediatric paranasal sinus CT using an ultralow tube voltage (70 kVp) combined with iterative reconstruction: Feasibility and image quality.

Authors:  Jing Chi; Dongfeng Xu; Shengnan Yin; Man Li; Li Shen; Ning Ding; Xiaofang Chen; Yiding Ji
Journal:  Medicine (Baltimore)       Date:  2020-08-21       Impact factor: 1.817

  10 in total