| Literature DB >> 20011062 |
K Kalmantis1, C Dimitrakakis, Ch Koumpis, A Tsigginou, N Papantoniou, S Mesogitis, A Antsaklis.
Abstract
Purpose. The aim of this study was to determine the value of 3D and 3D Power Doppler sonography in the detection of tumor malignancy in breast lesions and to find new diagnostic criteria for differential diagnosis. Methods. One hundred and twenty five women with clinically or mammographically suspicious findings were referred for 3D Power Doppler ultrasound prior to surgery. Histological diagnosis was conducted after surgery and compared with ultrasound findings. Sonographic criteria used for breast cancer diagnosis were based on a system that included morphological characteristics and criteria of the vascular pattern of a breast mass by Power Doppler imaging. Results. Seventy-two lesions were histopathologically diagnosed as benign and 53 tumors as malignant. Three-dimensional ultrasound identified 49 out of 53 histologically confirmed breast cancers resulting in a sensitivity of 92.4% and a specificity of 86.1% in diagnosing breast malignancy (PPV: 0.83, NPV:0.94). Conclusions. 3D ultrasonography is a valuable tool in identifying preoperatively the possibility of a tumor to be malignant.Entities:
Year: 2009 PMID: 20011062 PMCID: PMC2778558 DOI: 10.1155/2009/530579
Source DB: PubMed Journal: Obstet Gynecol Int ISSN: 1687-9597
3D Ultrasonographic criteria for breast tumors.
| (1) Shape | Round/oval | 0 |
| Lobular | 1 | |
| Irregular | 2 | |
|
| ||
| (2) Orientation | Wider than tall (W > T) | 0 |
| Not clear (W = T) | 1 | |
| Taller than wide (W < T) | 2 | |
|
| ||
| (3) Margin | Well defined | 0 |
| ILL defined (microlobulated) | 2 | |
|
| ||
| (4) Surrounding echogenicity | Hypoechogenic regular (pseydocapsule) | 0 |
| Echogenic irregular | 2 | |
|
| ||
| (5) Echogenicity | Hyperechoic | 0 |
| Hypoechoic | 2 | |
|
| ||
| (6) Echotexture | Homogenous | 0 |
| Inhomogenous | 2 | |
|
| ||
| (7) Acoustic transmission | Present (enhancement) | 0 |
| Absent | 2 | |
|
| ||
| (8) Pattern | Compression pattern | 0 |
| Retraction/star pattern | 2 | |
|
| ||
| (9) Vessels architecture | Linear | 0 |
| Chaotic-complex | 1 | |
|
| ||
| (10) R.I. | ≥0.42 | 0 |
| <0.42 | 1 | |
Figure 13D pictures of a fibroadenoma.
Figure 23D reconstruction of an invasive ductal carcinoma angulated with inhomogenous echotexture and retraction pattern.
3D Ultrasound findings compared with histopathology reports.
| 3D Ultrasound | Histopathology | ||
|---|---|---|---|
| Diagnosis | Histologicaly confirmed preoperative diagnoses | ||
| Benign | 66 | 62 (86,1%) | 72 |
| Malignant | 59 | 49 (92,4%) | 53 |
| Total | 125 | 111 (88,8%) | 125 |
Figure 3High diagnostic capability of 3D ultrasound in differentiating benign from malignant breast tumors.
3D outcome according to the sonographic criteria used in our breast tumor patients.
| Benign | CA | |||||
|---|---|---|---|---|---|---|
|
| % |
| % |
| ||
| Shape | Round/oval | 52 | 72.2% | 1 | 1.9% | <.0001 |
| Lobular | 20 | 27.8% | 10 | 18.9% | ||
| Irregular | 0 | 0% | 42 | 79.2% | ||
| Orientation | (W > T) | 49 | 68.1% | 4 | 7.5% | <.0001 |
| (W = T) | 21 | 29.2% | 5 | 9.4% | ||
| (W < T) | 2 | 2.8% | 44 | 83.0% | ||
| Margin | Well defined | 70 | 97.2% | 13 | 25% | <.0001 |
| ILL defined | 2 | 2.8% | 40 | 75% | ||
| Surrounding echogenicity | Hypoechogenic regular | 72 | 100.0% | 24 | 45.3% | .002 |
| Echogenic irregular | 0 | 0% | 29 | 54.7% | ||
| Echogenicity | Hyperechoic | 63 | 87.5% | 33 | 62.3% | .002 |
| Hypoechoic | 9 | 12.5% | 20 | 37.7% | ||
| Echotexture | Homogenous | 37 | 51.4% | 12 | 22.6% | <.0001 |
| Inhomogenous | 35 | 48.6% | 41 | 77.4% | ||
| Acoustic transmission | Present | 36 | 50.0% | 8 | 15.1% | <.0001 |
| Absent | 36 | 50.0% | 45 | 84.9% | ||
| Pattern | Compression pattern | 69 | 95.8% | 6 | 11.3% | <.0001 |
| Retraction/star pattern | 3 | 4.2% | 47 | 88.7% | ||
| Vessels architecture | Linear | 70 | 97.2% | 25 | 47.2% | <.0001 |
| Chaotic-complex | 2 | 2.8% | 28 | 52.8% | ||
| R.I. | ≥0.42 | 70 | 97.2% | 29 | 54.7% | <.0001 |
| <0.42 | 2 | 2.8% | 24 | 45.3% |
Figure 43D Power Doppler imaging of a malignant tumor with chaotic vessels' architecture and complex branching pattern.