Literature DB >> 20009194

A method for partial volume correction of PET-imaged tumor heterogeneity using expectation maximization with a spatially varying point spread function.

David L Barbee1, Ryan T Flynn, James E Holden, Robert J Nickles, Robert Jeraj.   

Abstract

Tumor heterogeneities observed in positron emission tomography (PET) imaging are frequently compromised by partial volume effects which may affect treatment prognosis, assessment or future implementations such as biologically optimized treatment planning (dose painting). This paper presents a method for partial volume correction of PET-imaged heterogeneous tumors. A point source was scanned on a GE Discovery LS at positions of increasing radii from the scanner's center to obtain the spatially varying point spread function (PSF). PSF images were fit in three dimensions to Gaussian distributions using least squares optimization. Continuous expressions were devised for each Gaussian width as a function of radial distance, allowing for generation of the system PSF at any position in space. A spatially varying partial volume correction (SV-PVC) technique was developed using expectation maximization (EM) and a stopping criterion based on the method's correction matrix generated for each iteration. The SV-PVC was validated using a standard tumor phantom and a tumor heterogeneity phantom and was applied to a heterogeneous patient tumor. SV-PVC results were compared to results obtained from spatially invariant partial volume correction (SINV-PVC), which used directionally uniform three-dimensional kernels. SV-PVC of the standard tumor phantom increased the maximum observed sphere activity by 55 and 40% for 10 and 13 mm diameter spheres, respectively. Tumor heterogeneity phantom results demonstrated that as net changes in the EM correction matrix decreased below 35%, further iterations improved overall quantitative accuracy by less than 1%. SV-PVC of clinically observed tumors frequently exhibited changes of +/-30% in regions of heterogeneity. The SV-PVC method implemented spatially varying kernel widths and automatically determined the number of iterations for optimal restoration, parameters which are arbitrarily chosen in SINV-PVC. Comparing SV-PVC to SINV-PVC demonstrated that similar results could be reached using both methods, but large differences result for the arbitrary selection of SINV-PVC parameters. The presented SV-PVC method was performed without user intervention, requiring only a tumor mask as input. Research involving PET-imaged tumor heterogeneity should include correcting for partial volume effects to improve the quantitative accuracy of results.

Entities:  

Mesh:

Year:  2010        PMID: 20009194      PMCID: PMC2954051          DOI: 10.1088/0031-9155/55/1/013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  38 in total

Review 1.  The hallmarks of cancer.

Authors:  D Hanahan; R A Weinberg
Journal:  Cell       Date:  2000-01-07       Impact factor: 41.582

2.  Positron emission tomography partial volume correction: estimation and algorithms.

Authors:  John A D Aston; Vincent J Cunningham; Marie-Claude Asselin; Alexander Hammers; Alan C Evans; Roger N Gunn
Journal:  J Cereb Blood Flow Metab       Date:  2002-08       Impact factor: 6.200

3.  Object dependency of resolution in reconstruction algorithms with interiteration filtering applied to PET data.

Authors:  Sanida Mustafovic; Kris Thielemans
Journal:  IEEE Trans Med Imaging       Date:  2004-04       Impact factor: 10.048

4.  Quantitation of the human basal ganglia with positron emission tomography: a phantom study of the effect of contrast and axial positioning.

Authors:  B Bendriem; S L Dewey; D J Schlyer; A P Wolf; N D Volkow
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

Review 5.  Oncologic PET tracers beyond [(18)F]FDG and the novel quantitative approaches in PET imaging.

Authors:  R Kumar; H Dhanpathi; S Basu; D Rubello; S Fanti; A Alavi
Journal:  Q J Nucl Med Mol Imaging       Date:  2008-03       Impact factor: 2.346

6.  Radioactive spheres without inactive wall for lesion simulation in PET.

Authors:  Marisa Bazañez-Borgert; Ralph A Bundschuh; Michael Herz; Maria-Jose Martínez; Markus Schwaiger; Sibylle I Ziegler
Journal:  Z Med Phys       Date:  2008       Impact factor: 4.820

7.  Performance characteristics of a whole-body PET scanner.

Authors:  T R DeGrado; T G Turkington; J J Williams; C W Stearns; J M Hoffman; R E Coleman
Journal:  J Nucl Med       Date:  1994-08       Impact factor: 10.057

Review 8.  Tumor heterogeneity.

Authors:  G H Heppner
Journal:  Cancer Res       Date:  1984-06       Impact factor: 12.701

9.  Partial-volume correction in PET: validation of an iterative postreconstruction method with phantom and patient data.

Authors:  Boon-Keng Teo; Youngho Seo; Stephen L Bacharach; Jorge A Carrasquillo; Steven K Libutti; Himanshu Shukla; Bruce H Hasegawa; Randall A Hawkins; Benjamin L Franc
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

10.  Spatial heterogeneity in sarcoma 18F-FDG uptake as a predictor of patient outcome.

Authors:  Janet F Eary; Finbarr O'Sullivan; Janet O'Sullivan; Ernest U Conrad
Journal:  J Nucl Med       Date:  2008-11-07       Impact factor: 10.057

View more
  14 in total

1.  Classification and evaluation strategies of auto-segmentation approaches for PET: Report of AAPM task group No. 211.

Authors:  Mathieu Hatt; John A Lee; Charles R Schmidtlein; Issam El Naqa; Curtis Caldwell; Elisabetta De Bernardi; Wei Lu; Shiva Das; Xavier Geets; Vincent Gregoire; Robert Jeraj; Michael P MacManus; Osama R Mawlawi; Ursula Nestle; Andrei B Pugachev; Heiko Schöder; Tony Shepherd; Emiliano Spezi; Dimitris Visvikis; Habib Zaidi; Assen S Kirov
Journal:  Med Phys       Date:  2017-05-18       Impact factor: 4.071

Review 2.  Radiotherapy for head and neck tumours in 2012 and beyond: conformal, tailored, and adaptive?

Authors:  Vincent Grégoire; Robert Jeraj; John Aldo Lee; Brian O'Sullivan
Journal:  Lancet Oncol       Date:  2012-06-28       Impact factor: 41.316

3.  Design and evaluation of an accurate CNR-guided small region iterative restoration-based tumor segmentation scheme for PET using both simulated and real heterogeneous tumors.

Authors:  Alpaslan Koç; Albert Güveniş
Journal:  Med Biol Eng Comput       Date:  2019-12-17       Impact factor: 2.602

Review 4.  The physical basis and future of radiation therapy.

Authors:  T Bortfeld; R Jeraj
Journal:  Br J Radiol       Date:  2011-06       Impact factor: 3.039

Review 5.  Functional and molecular image guidance in radiotherapy treatment planning optimization.

Authors:  Shiva K Das; Randall K Ten Haken
Journal:  Semin Radiat Oncol       Date:  2011-04       Impact factor: 5.934

6.  PET Image Deblurring and Super-Resolution with an MR-Based Joint Entropy Prior.

Authors:  Tzu-An Song; Fan Yang; Samadrita Roy Chowdhury; Kyungsang Kim; Keith A Johnson; Georges El Fakhri; Quanzheng Li; Joyita Dutta
Journal:  IEEE Trans Comput Imaging       Date:  2019-04-25

7.  Simultaneous Tumor Segmentation, Image Restoration, and Blur Kernel Estimation in PET Using Multiple Regularizations.

Authors:  Laquan Li; Jian Wang; Wei Lu; Shan Tan
Journal:  Comput Vis Image Underst       Date:  2016-10-06       Impact factor: 3.876

8.  Correlation of PET images of metabolism, proliferation and hypoxia to characterize tumor phenotype in patients with cancer of the oropharynx.

Authors:  Matthew J Nyflot; Paul M Harari; Stephen Yip; Scott B Perlman; Robert Jeraj
Journal:  Radiother Oncol       Date:  2012-10-13       Impact factor: 6.280

9.  Asphericity of pretherapeutic tumour FDG uptake provides independent prognostic value in head-and-neck cancer.

Authors:  Ivayla Apostolova; Ingo G Steffen; Florian Wedel; Alexandr Lougovski; Simone Marnitz; Thorsten Derlin; Holger Amthauer; Ralph Buchert; Frank Hofheinz; Winfried Brenner
Journal:  Eur Radiol       Date:  2014-06-26       Impact factor: 5.315

10.  A method for model-free partial volume correction in oncological PET.

Authors:  Frank Hofheinz; Jens Langner; Jan Petr; Bettina Beuthien-Baumann; Liane Oehme; Jörg Steinbach; Jörg Kotzerke; Jörg van den Hoff
Journal:  EJNMMI Res       Date:  2012-04-24       Impact factor: 3.138

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.