Literature DB >> 18524386

Radioactive spheres without inactive wall for lesion simulation in PET.

Marisa Bazañez-Borgert1, Ralph A Bundschuh, Michael Herz, Maria-Jose Martínez, Markus Schwaiger, Sibylle I Ziegler.   

Abstract

With the growing importance of PET and PET/CT in diagnosis, staging, therapy monitoring and radiotherapy planning, appropriate tools to simulate lesions in phantoms are important. Normally hollow spheres, made of plastic or glass, which can be filled with radioactive solutions, are used. As these spheres have an inactive wall they do not reflect the real situation in the patient and lead to quantification errors in the presence of background activity. We propose spheres made of radioactive wax, which are easy to produce, give a high flexibility to the user and a more accurate quantification. These wax spheres were evaluated for their applicability in PET phantoms and it was found that the activity is not diffusing into the surrounding water in relevant quantities, that they show a sufficient homogeneity, and that their attenuation properties are equivalent to water for photons of PET energies. Recovery coefficients for the wax spheres were measured and compared with those obtained for fillable plastic spheres for diameters of 28, 16, 10, and 6 mm in the presence of background activity. Recovery coefficients of the wax spheres were found to be up to 21% higher than for the fillable spheres.

Entities:  

Mesh:

Year:  2008        PMID: 18524386     DOI: 10.1016/j.zemedi.2007.06.001

Source DB:  PubMed          Journal:  Z Med Phys        ISSN: 0939-3889            Impact factor:   4.820


  10 in total

Review 1.  PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques.

Authors:  Habib Zaidi; Issam El Naqa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03-25       Impact factor: 9.236

2.  Estimation of the minimum detectable activity of preclinical PET imaging systems with an analytical method.

Authors:  Qinan Bao; Arion F Chatziioannou
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

3.  Quantitative assessment of glucose metabolism in the vessel wall of abdominal aortic aneurysms: correlation with histology and role of partial volume correction.

Authors:  Christian Reeps; Ralph A Bundschuh; Jaroslav Pellisek; Michael Herz; Sandra van Marwick; Markus Schwaiger; Hans-Henning Eckstein; Stephan G Nekolla; Markus Essler
Journal:  Int J Cardiovasc Imaging       Date:  2012-07-07       Impact factor: 2.357

4.  Determination of accuracy and precision of lesion uptake measurements in human subjects with time-of-flight PET.

Authors:  Margaret E Daube-Witherspoon; Suleman Surti; Amy E Perkins; Joel S Karp
Journal:  J Nucl Med       Date:  2014-03-06       Impact factor: 10.057

5.  A method for partial volume correction of PET-imaged tumor heterogeneity using expectation maximization with a spatially varying point spread function.

Authors:  David L Barbee; Ryan T Flynn; James E Holden; Robert J Nickles; Robert Jeraj
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

6.  PET-based delineation of tumour volumes in lung cancer: comparison with pathological findings.

Authors:  Andrea Schaefer; Yoo Jin Kim; Stephanie Kremp; Sebastian Mai; Jochen Fleckenstein; Hendrik Bohnenberger; Hans-Joachim Schäfers; Jan-Martin Kuhnigk; Rainer M Bohle; Christian Rübe; Carl-Martin Kirsch; Aleksandar Grgic
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-04-30       Impact factor: 9.236

7.  A method for model-free partial volume correction in oncological PET.

Authors:  Frank Hofheinz; Jens Langner; Jan Petr; Bettina Beuthien-Baumann; Liane Oehme; Jörg Steinbach; Jörg Kotzerke; Jörg van den Hoff
Journal:  EJNMMI Res       Date:  2012-04-24       Impact factor: 3.138

8.  Quantitative evaluation of PSMA PET imaging using a realistic anthropomorphic phantom and shell-less radioactive epoxy lesions.

Authors:  Roberto Fedrigo; Dan J Kadrmas; Patricia E Edem; Lauren Fougner; Ivan S Klyuzhin; M Peter Petric; François Bénard; Arman Rahmim; Carlos Uribe
Journal:  EJNMMI Phys       Date:  2022-01-15

9.  A novel phantom technique for evaluating the performance of PET auto-segmentation methods in delineating heterogeneous and irregular lesions.

Authors:  B Berthon; C Marshall; R Holmes; E Spezi
Journal:  EJNMMI Phys       Date:  2015-06-27

10.  The influence of different signal-to-background ratios on spatial resolution and F18-FDG-PET quantification using point spread function and time-of-flight reconstruction.

Authors:  Julian Mm Rogasch; Frank Hofheinz; Alexandr Lougovski; Christian Furth; Juri Ruf; Oliver S Großer; Konrad Mohnike; Peter Hass; Mathias Walke; Holger Amthauer; Ingo G Steffen
Journal:  EJNMMI Phys       Date:  2014-09-19
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.