Literature DB >> 20004589

Analysis of selective androgen receptor modulators by gas chromatography-microchip atmospheric pressure photoionization-mass spectrometry.

Laura Luosujärvi1, Markus Haapala, Mario Thevis, Ville Saarela, Sami Franssila, Raimo A Ketola, Risto Kostiainen, Tapio Kotiaho.   

Abstract

A gas chromatography-microchip atmospheric pressure photoionization-mass spectrometric (GC-microAPPI-MS) method was developed and used for the analysis of three 2-quinolinone-derived selective androgen receptor modulators (SARMs). SARMs were analyzed from spiked urine samples, which were hydrolyzed and derivatized with N-methyl-N-(trimethylsilyl)trifluoroacetamide before analysis. Trimethylsilyl derivatives of SARMs formed both radical cations (M(+*)) and protonated molecules ([M + H](+)) in photoionization. Better signal-to-noise ratios (S/N) were obtained in MS/MS analysis using the M(+*) ions as precursor ions than using the [M + H](+) ions, and therefore the M(+*) ions were selected for the precursor ions in selected reaction monitoring (SRM) analysis. Limits of detection (LODs) with the method ranged from 0.01 to 1 ng/mL, which correspond to instrumental LODs of 0.2-20 pg. Limits of quantitation ranged from 0.03 to 3 ng/mL. The mass spectrometric response to the analytes was linear (R > or = 0.995) from the LOQ concentration level up to 100 ng/mL concentration, and intra-day repeatabilities were 5%-9%. In addition to the GC-microAPPI-MS study, the proof-of-principle of gas chromatography-microchip atmospheric pressure chemical ionization-Orbitrap MS (GC-microAPCI-Orbitrap MS) was demonstrated. 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20004589     DOI: 10.1016/j.jasms.2009.10.019

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  28 in total

1.  Microchip atmospheric pressure chemical ionization source for mass spectrometry.

Authors:  Pekka Ostman; Seppo J Marttila; Tapio Kotiaho; Sami Franssila; Risto Kostiainen
Journal:  Anal Chem       Date:  2004-11-15       Impact factor: 6.986

Review 2.  Non-steroidal steroid receptor modulators.

Authors:  Rogier C Buijsman; Pedro H H Hermkens; Rachel D van Rijn; H Thijs Stock; N Miranda Teerhuis
Journal:  Curr Med Chem       Date:  2005       Impact factor: 4.530

3.  Capillary liquid chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry.

Authors:  Pekka Ostman; Sirkku Jäntti; Kestas Grigoras; Ville Saarela; Raimo A Ketola; Sami Franssila; Tapio Kotiaho; Risto Kostiainen
Journal:  Lab Chip       Date:  2006-04-27       Impact factor: 6.799

4.  Gas chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry.

Authors:  Pekka Ostman; Laura Luosujärvi; Markus Haapala; Kestas Grigoras; Raimo A Ketola; Tapio Kotiaho; Sami Franssila; Risto Kostiainen
Journal:  Anal Chem       Date:  2006-05-01       Impact factor: 6.986

5.  Discovery of 6-N,N-bis(2,2,2-trifluoroethyl)amino- 4-trifluoromethylquinolin-2(1H)-one as a novel selective androgen receptor modulator.

Authors:  Arjan van Oeveren; Mehrnouch Motamedi; Neelakandha S Mani; Keith B Marschke; Francisco J López; William T Schrader; Andrés Negro-Vilar; Lin Zhi
Journal:  J Med Chem       Date:  2006-10-19       Impact factor: 7.446

6.  Microchip sonic spray ionization.

Authors:  Jaroslav Pól; Tiina J Kauppila; Markus Haapala; Ville Saarela; Sami Franssila; Raimo A Ketola; Tapio Kotiaho; Risto Kostiainen
Journal:  Anal Chem       Date:  2007-03-24       Impact factor: 6.986

7.  Microchip for combining gas chromatography or capillary liquid chromatography with atmospheric pressure photoionization-mass spectrometry.

Authors:  Markus Haapala; Laura Luosujärvi; Ville Saarela; Tapio Kotiaho; Raimo A Ketola; Sami Franssila; Risto Kostiainen
Journal:  Anal Chem       Date:  2007-05-26       Impact factor: 6.986

8.  Atmospheric pressure photoionization-mass spectrometry with a microchip heated nebulizer.

Authors:  Tiina J Kauppila; Pekka Ostman; Seppo Marttila; Raimo A Ketola; Tapio Kotiaho; Sami Franssila; Risto Kostiainen
Journal:  Anal Chem       Date:  2004-11-15       Impact factor: 6.986

9.  Desorption atmospheric pressure photoionization.

Authors:  Markus Haapala; Jaroslav Pól; Ville Saarela; Ville Arvola; Tapio Kotiaho; Raimo A Ketola; Sami Franssila; Tiina J Kauppila; Risto Kostiainen
Journal:  Anal Chem       Date:  2007-09-06       Impact factor: 6.986

10.  New nonsteroidal androgen receptor modulators based on 4-(trifluoromethyl)-2(1H)-pyrrolidino[3,2-g] quinolinone.

Authors:  J P Edwards; S J West; C L Pooley; K B Marschke; L J Farmer; T K Jones
Journal:  Bioorg Med Chem Lett       Date:  1998-04-07       Impact factor: 2.823

View more
  1 in total

1.  The ionization mechanisms in direct and dopant-assisted atmospheric pressure photoionization and atmospheric pressure laser ionization.

Authors:  Tiina J Kauppila; Hendrik Kersten; Thorsten Benter
Journal:  J Am Soc Mass Spectrom       Date:  2014-09-24       Impact factor: 3.109

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.