Literature DB >> 17530739

Microchip for combining gas chromatography or capillary liquid chromatography with atmospheric pressure photoionization-mass spectrometry.

Markus Haapala1, Laura Luosujärvi, Ville Saarela, Tapio Kotiaho, Raimo A Ketola, Sami Franssila, Risto Kostiainen.   

Abstract

We present a microfabricated nebulizer chip for combining atmospheric pressure photoionization-mass spectrometry (APPI-MS) with gas chromatography (GC) or capillary liquid chromatography (capLC). The chip consists of a silicon plate and a glass plate or two glass plates. The chip includes a sample inlet channel, auxiliary gas and dopant inlet, vaporizer channel, nozzle, and platinum heater. The sample eluted from the capLC or GC is mixed with auxiliary gas and dopant (toluene) in the heated vaporizer. The chip forms a confined jet of the sample vapor, which is photoionized as it exits the chip. The analytical performance of GC- and capLC-microchip APPI-MS was evaluated with some polycyclic aromatic hydrocarbons, amphetamines, and steroids. The GC-muAPPI-MS method provides high sensitivity down to 0.8 fmol, repeatability (RSD = 7.5-14%), and linearity (r = 0.9952-0.9987). The capLC-muAPPI-MS method shows high sensitivity down to 1 fmol, good repeatability (RSD = 3.6-8.1%), and linearity (r = 0.9989-0.9992).

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17530739     DOI: 10.1021/ac070157a

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Analysis of selective androgen receptor modulators by gas chromatography-microchip atmospheric pressure photoionization-mass spectrometry.

Authors:  Laura Luosujärvi; Markus Haapala; Mario Thevis; Ville Saarela; Sami Franssila; Raimo A Ketola; Risto Kostiainen; Tapio Kotiaho
Journal:  J Am Soc Mass Spectrom       Date:  2009-11-06       Impact factor: 3.109

2.  Ionization of EPA contaminants in direct and dopant-assisted atmospheric pressure photoionization and atmospheric pressure laser ionization.

Authors:  Tiina J Kauppila; Hendrik Kersten; Thorsten Benter
Journal:  J Am Soc Mass Spectrom       Date:  2015-04-01       Impact factor: 3.109

3.  Design, fabrication and test of a microfluidic nebulizer chip for desorption electrospray ionization mass spectrometry.

Authors:  A K Sen; J Darabi; D R Knapp
Journal:  Sens Actuators B Chem       Date:  2009-04-02       Impact factor: 7.460

4.  Detection of carbohydrates and steroids by cation-enhanced nanostructure-initiator mass spectrometry (NIMS) for biofluid analysis and tissue imaging.

Authors:  Gary J Patti; Hin-Koon Woo; Oscar Yanes; Leah Shriver; Diane Thomas; Wilasinee Uritboonthai; Junefredo V Apon; Rick Steenwyk; Marianne Manchester; Gary Siuzdak
Journal:  Anal Chem       Date:  2010-01-01       Impact factor: 6.986

5.  The ionization mechanisms in direct and dopant-assisted atmospheric pressure photoionization and atmospheric pressure laser ionization.

Authors:  Tiina J Kauppila; Hendrik Kersten; Thorsten Benter
Journal:  J Am Soc Mass Spectrom       Date:  2014-09-24       Impact factor: 3.109

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.