Literature DB >> 1999040

Intravascular ultrasound imaging of human coronary arteries in vivo. Analysis of tissue characterizations with comparison to in vitro histological specimens.

J M Tobis1, J Mallery, D Mahon, K Lehmann, P Zalesky, J Griffith, J Gessert, M Moriuchi, M McRae, M L Dwyer.   

Abstract

BACKGROUND: Intravascular ultrasound imaging was performed in 27 patients after coronary balloon angioplasty to quantify the lumen and atheroma cross-sectional areas. METHODS AND
RESULTS: A 20-MHz ultrasound catheter was inserted through a 1.6-mm plastic introducer sheath across the dilated area to obtain real-time images at 30 times/sec. The ultrasound images distinguished the lumen from atheroma, calcification, and the muscular media. The presence of dissection between the media and the atheroma was well visualized. These observations of tissue characterization were compared with an in vitro study of 20 human atherosclerotic artery segments that correlated the ultrasound images to histological preparations. The results indicate that high-quality intravascular ultrasound images under controlled in vitro conditions can provide accurate microanatomic information about the histological characteristics of atherosclerotic plaques. Similar quality cross-sectional ultrasound images were also obtained in human coronary arteries in vivo. Quantitative analysis of the ultrasound images from the clinical studies revealed that the mean cross-sectional lumen area after balloon angioplasty was 5.0 +/- 2.0 mm2. The mean residual atheroma area at the level of the prior dilatation was 8.7 +/- 3.4 mm2, which corresponded to 63% of the available arterial cross-sectional area. At the segments of the coronary artery that appeared angiographically normal, the ultrasound images demonstrated the presence of atheroma involving 4.7 +/- 3.2 mm2, which was a mean of 35 +/- 23% of the available area bounded by the media.
CONCLUSIONS: Intravascular ultrasound appears to be more sensitive than angiography for demonstrating the presence and extent of atherosclerosis and arterial calcification. Intracoronary imaging after balloon angioplasty reveals that a significant amount of atheroma is still present, which may partly explain why the incidence of restenosis is high after percutaneous transluminal coronary angioplasty.

Entities:  

Mesh:

Year:  1991        PMID: 1999040     DOI: 10.1161/01.cir.83.3.913

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  59 in total

1.  Assessment of the mechanical properties of coronary arteries using intravascular ultrasound: an in vivo study.

Authors:  M J Williams; R A Stewart; C J Low; G T Wilkins
Journal:  Int J Card Imaging       Date:  1999-08

2.  Reliability of mechanical and phased-array designs for serial intravascular ultrasound examinations--animal and clinical studies in stented and non-stented coronary arteries.

Authors:  J C Tardif; O F Bertrand; R Mongrain; J Lespérance; J Grégoire; P Paiement; R Bonan
Journal:  Int J Card Imaging       Date:  2000-10

3.  Intravascular ultrasound imaging of the coronary arteries: an in vitro evaluation of measurement of area of the lumen and atheroma characterisation.

Authors:  M H Anderson; I A Simpson; D Katritsis; M J Davies; D E Ward
Journal:  Br Heart J       Date:  1992-09

4.  Application of intravascular ultrasonography for intracaval tumor thrombectomies in adrenal metastasis from hepatocellular carcinoma: report of two cases.

Authors:  Y Shimahara; T Shibata; T Morimoto; N Yamamoto; Y Iimuro; Y Yamamoto; I Ikai; Y Yamaoka
Journal:  Surg Today       Date:  1999       Impact factor: 2.549

Review 5.  [Progression and regression of atherosclerotic plaques. New results based on intracoronary ultrasound].

Authors:  Raimund Erbel
Journal:  Herz       Date:  2015-09       Impact factor: 1.443

6.  Atherosclerosis imaging with intravascular ultrasound. Validating acquisition and measurement tools to assure meaningful results.

Authors:  Paul Schoenhagen
Journal:  Int J Cardiovasc Imaging       Date:  2006-10       Impact factor: 2.357

Review 7.  Optical coherence tomography for imaging the vulnerable plaque.

Authors:  Guillermo J Tearney; Ik-Kyung Jang; Brett E Bouma
Journal:  J Biomed Opt       Date:  2006 Mar-Apr       Impact factor: 3.170

8.  Quantitative assessment of peripheral and coronary artery lesions before and after balloon angioplasty: a comparison of intravascular ultrasound and angiography.

Authors:  M Schartl; W Bocksch; T Linderer; S Beckmann; S Dreysse
Journal:  Heart Vessels       Date:  1994       Impact factor: 2.037

9.  Intravascular ultrasonography of supra-aortic arteries as an adjunct to percutaneous transluminal angioplasty.

Authors:  T Hirai; Y Korogi; Y Sakamoto; S Hamatake; M Takahashi
Journal:  Neuroradiology       Date:  1995-07       Impact factor: 2.804

10.  High-resolution visualization of mouse cardiac microvasculature using optical histology.

Authors:  Austin J Moy; Patrick C Lo; Bernard Choi
Journal:  Biomed Opt Express       Date:  2013-12-04       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.