Fetal monitoring with pulse oximetry.

N Johnson1, V A Johnson, J Fisher, B Jobbings, J Bannister, R J Lilford.   

Abstract

Continuous fetal monitoring was achieved with a fetal scalp pulse oximetry sensor in 86 labours. The average recorded fetal oxygen saturation in early labour (cervical dilatation less than 5 cm) was 68% (SD 13%). At the end of labour (cervical dilatation greater than or equal to 9 cm) the recorded mean oxygen saturation was 58% (SD 17%). The largest range of readings during a single labour was 81%-11% but this drop was associated with cord compression. The average SD during 1 h of normal labour was 10%. A second group of 40 fetuses was monitored during induction of labour before and after elective amniotomy. Oxygen saturation did not appear to change after amniotomy (mean change -0.4%, SD 1.2%) and there was no difference between mean antenatal or early intrapartum readings. We excluded the amniochorionic membranes as a possible source of data corruption by measuring their in vitro absorption spectra and confirming that they do not preferentially absorb light of either 660 or 940 nm wavelength. Non-invasive pulse oximetry can be used to monitor the fetus before and during labour.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1998630     DOI: 10.1111/j.1471-0528.1991.tb10308.x

Source DB:  PubMed          Journal:  Br J Obstet Gynaecol        ISSN: 0306-5456


  12 in total

1.  Reflectance pulse oximetry--principles and obstetric application in the Zurich system.

Authors:  V König; R Huch; A Huch
Journal:  J Clin Monit Comput       Date:  1998-08       Impact factor: 2.502

Review 2.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

Review 3.  Factors influencing fetal pulse oximetry performance.

Authors:  James L Reuss
Journal:  J Clin Monit Comput       Date:  2004-02       Impact factor: 2.502

4.  Reducing risk in obstetrics.

Authors:  J Drife
Journal:  Qual Health Care       Date:  1995-06

5.  Reflectance pulse oximetry in fetal lambs: subcutaneous vessels and vasoconstriction affect its reliability.

Authors:  R Nijland; H W Jongsma; I M Verbruggen; J G Nijhuis
Journal:  J Clin Monit       Date:  1996-05

6.  Intrapartum reflectance pulse oximetry: effects of sensor location and fixation duration on oxygen saturation readings.

Authors:  K Faisst; P Kirkinen; V König; A Huch; R Huch
Journal:  J Clin Monit       Date:  1997-09

7. 

Authors:  F Béguin
Journal:  Arch Gynecol Obstet       Date:  1995-12       Impact factor: 2.344

8.  Cardiotocography during labour.

Authors:  J Neilson
Journal:  BMJ       Date:  1993-02-06

9.  Validation of reflectance pulse oximetry: an evaluation of a new sensor in piglets.

Authors:  R Nijland; S Nierlich; H W Jongsma; J G Nijhuis; B Oeseburg; K Springer; P Mannheimer
Journal:  J Clin Monit       Date:  1997-01

10.  Anesthesia for in utero repair of myelomeningocele.

Authors:  Marla Ferschl; Robert Ball; Hanmin Lee; Mark D Rollins
Journal:  Anesthesiology       Date:  2013-05       Impact factor: 7.892

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.