Literature DB >> 19964480

In vitro testing of floating light activated micro-electrical stimulators.

Ammar Abdo1, Vianney Jayasinha, Philipp S Spuhler, M Unlu, Mesut Sahin.   

Abstract

Chronic tissue response to microelectrode implants stands in the way as a major challenge to development of many neural prosthetic applications. The long term tissue response is mostly due to the movement of interconnects and the resulting mechanical stress between the electrode and the surrounding neural tissue. Remotely activated floating micro-stimulators are one possible method of eliminating the interconnects. As a method of energy transfer to the micro-stimulator, we proposed to use a laser beam at near infrared (NIR) wavelengths. FLAMES of various sizes were fabricated with integrated silicon PIN photodiodes. Sizes varied from 120 (Width) x 300 (Length) x 100 (Height) microm to 200 x 500 x 100microm. Devices were bench tested using 850nm excitation from a Ti:Sapphire laser. To test this method, the voltage field of the FLAMES was experimentally tested in saline solution pulsed with a NIR laser beam. The voltage generated is around 196mV in peak at the cathodic contact as a response to a single pulse. When a train of laser pulses was applied at 100Hz, the peak voltage at the cathodic contact remained around 141mV suggesting the feasibility of this approach for applications with pulse frequencies up to 100Hz.

Entities:  

Mesh:

Year:  2009        PMID: 19964480      PMCID: PMC2848066          DOI: 10.1109/IEMBS.2009.5334073

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  7 in total

1.  Multi-joint movement of the cat hindlimb evoked by microstimulation of the lumbosacral spinal cord.

Authors:  Changfeng Tai; August M Booth; Charles J Robinson; William C de Groat; James R Roppolo
Journal:  Exp Neurol       Date:  2003-10       Impact factor: 5.330

2.  Intraspinal microstimulation generates functional movements after spinal-cord injury.

Authors:  Rajiv Saigal; Costantino Renzi; Vivian K Mushahwar
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2004-12       Impact factor: 3.802

3.  Finite element analysis of a floating microstimulator.

Authors:  Mesut Sahin; Syed S Ur-Rahman
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2007-06       Impact factor: 3.802

4.  A compact architecture for three-dimensional neural microelectrode arrays.

Authors:  Gayatri E Perlin; Kensall D Wise
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

5.  Optical properties of human brain tissue, meninges, and brain tumors in the spectral range of 200 to 900 nm.

Authors:  H R Eggert; V Blazek
Journal:  Neurosurgery       Date:  1987-10       Impact factor: 4.654

6.  On the influence of volume currents and extended sources on neuromagnetic fields: a simulation study.

Authors:  J Haueisen; C Ramon; P Czapski; M Eiselt
Journal:  Ann Biomed Eng       Date:  1995 Nov-Dec       Impact factor: 3.934

7.  Intraspinal micro stimulation generates locomotor-like and feedback-controlled movements.

Authors:  Vivian K Mushahwar; Deborah M Gillard; Michel J A Gauthier; Arthur Prochazka
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2002-03       Impact factor: 3.802

  7 in total
  5 in total

1.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

2.  Temperature elevation profile inside the rat brain induced by a laser beam.

Authors:  Ali Ersen; Ammar Abdo; Mesut Sahin
Journal:  J Biomed Opt       Date:  2014-01       Impact factor: 3.170

3.  Floating light-activated microelectrical stimulators tested in the rat spinal cord.

Authors:  Ammar Abdo; Mesut Sahin; David S Freedman; Elif Cevik; Philipp S Spuhler; M Selim Unlu
Journal:  J Neural Eng       Date:  2011-09-14       Impact factor: 5.379

Review 4.  Spinal primitives and intra-spinal micro-stimulation (ISMS) based prostheses: a neurobiological perspective on the "known unknowns" in ISMS and future prospects.

Authors:  Simon F Giszter
Journal:  Front Neurosci       Date:  2015-03-20       Impact factor: 4.677

5.  Improved selectivity from a wavelength addressable device for wireless stimulation of neural tissue.

Authors:  Elif Ç Seymour; David S Freedman; Mutlu Gökkavas; Ekmel Ozbay; Mesut Sahin; M Selim Unlü
Journal:  Front Neuroeng       Date:  2014-02-18
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.