Literature DB >> 21914931

Floating light-activated microelectrical stimulators tested in the rat spinal cord.

Ammar Abdo1, Mesut Sahin, David S Freedman, Elif Cevik, Philipp S Spuhler, M Selim Unlu.   

Abstract

Microelectrodes of neural stimulation utilize fine wires for electrical connections to driving electronics. Breakage of these wires and the neural tissue response due to their tethering forces are major problems encountered with long-term implantation of microelectrodes. The lifetime of an implant for neural stimulation can be substantially improved if the wire interconnects are eliminated. Thus, we proposed a floating light-activated microelectrical stimulator (FLAMES) for wireless neural stimulation. In this paradigm, a laser beam at near infrared (NIR) wavelengths will be used as a means of energy transfer to the device. In this study, microstimulators of various sizes were fabricated, with two cascaded GaAs p-i-n photodiodes, and tested in the rat spinal cord. A train of NIR pulses (0.2 ms, 50 Hz) was sent through the tissue to wirelessly activate the devices and generate the stimulus current. The forces elicited by intraspinal stimulation were measured from the ipsilateral forelimb with a force transducer. The largest forces were around 1.08 N, a significant level of force for the rat forelimb motor function. These in vivo tests suggest that the FLAMES can be used for intraspinal microstimulation even for the deepest implant locations in the rat spinal cord. The power required to generate a threshold arm movement was investigated as the laser source was moved away from the microstimulator. The results indicate that the photon density does not decrease substantially for horizontal displacements of the source that are in the same order as the beam radius. This gives confidence that the stimulation threshold may not be very sensitive to small displacement of the spinal cord relative to the spine-mounted optical power source.

Entities:  

Mesh:

Year:  2011        PMID: 21914931      PMCID: PMC3205078          DOI: 10.1088/1741-2560/8/5/056012

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  36 in total

1.  BION system for distributed neural prosthetic interfaces.

Authors:  G E Loeb; R A Peck; W H Moore; K Hood
Journal:  Med Eng Phys       Date:  2001-01       Impact factor: 2.242

2.  Spinal cord microstimulation generates functional limb movements in chronically implanted cats.

Authors:  V K Mushahwar; D F Collins; A Prochazka
Journal:  Exp Neurol       Date:  2000-06       Impact factor: 5.330

3.  Optical properties of selected native and coagulated human brain tissues in vitro in the visible and near infrared spectral range.

Authors:  A N Yaroslavsky; P C Schulze; I V Yaroslavsky; R Schober; F Ulrich; H J Schwarzmaier
Journal:  Phys Med Biol       Date:  2002-06-21       Impact factor: 3.609

4.  Responses to spinal microstimulation in the chronically spinalized rat and their relationship to spinal systems activated by low threshold cutaneous stimulation.

Authors:  M C Tresch; E Bizzi
Journal:  Exp Brain Res       Date:  1999-12       Impact factor: 1.972

5.  Bio-heat transfer model of deep brain stimulation-induced temperature changes.

Authors:  Maged M Elwassif; Qingjun Kong; Maribel Vazquez; Marom Bikson
Journal:  J Neural Eng       Date:  2006-11-06       Impact factor: 5.379

6.  The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull.

Authors:  Roy Biran; Dave C Martin; Patrick A Tresco
Journal:  J Biomed Mater Res A       Date:  2007-07       Impact factor: 4.396

7.  Neuronal loss due to prolonged controlled-current stimulation with chronically implanted microelectrodes in the cat cerebral cortex.

Authors:  Douglas McCreery; Victor Pikov; Philip R Troyk
Journal:  J Neural Eng       Date:  2010-05-11       Impact factor: 5.379

8.  Hindlimb endpoint forces predict movement direction evoked by intraspinal microstimulation in cats.

Authors:  Michel A Lemay; Dane Grasse; Warren M Grill
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2009-06-02       Impact factor: 3.802

9.  Electrochemical fabrication of conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) nanofibrils on microfabricated neural prosthetic devices.

Authors:  Junyan Yang; Karen Lipkin; David C Martin
Journal:  J Biomater Sci Polym Ed       Date:  2007       Impact factor: 3.517

10.  Intraspinal stimulation for bladder voiding in cats before and after chronic spinal cord injury.

Authors:  Victor Pikov; Leo Bullara; Douglas B McCreery
Journal:  J Neural Eng       Date:  2007-10-02       Impact factor: 5.379

View more
  14 in total

1.  A PDMS-based optical waveguide for transcutaneous powering of microelectrode arrays.

Authors:  Ali Ersen; Mesut Sahin
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2016-08

2.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

3.  Temperature elevation profile inside the rat brain induced by a laser beam.

Authors:  Ali Ersen; Ammar Abdo; Mesut Sahin
Journal:  J Biomed Opt       Date:  2014-01       Impact factor: 3.170

4.  Near-infrared light penetration profile in the rodent brain.

Authors:  Ammar Abdo; Ali Ersen; Mesut Sahin
Journal:  J Biomed Opt       Date:  2013-07       Impact factor: 3.170

5.  Photoelectric artefact from optogenetics and imaging on microelectrodes and bioelectronics: New Challenges and Opportunities.

Authors:  Takashi D Y Kozai; Alberto L Vazquez
Journal:  J Mater Chem B       Date:  2015-07-07       Impact factor: 6.331

6.  Chronic tissue response to untethered microelectrode implants in the rat brain and spinal cord.

Authors:  Ali Ersen; Stella Elkabes; David S Freedman; Mesut Sahin
Journal:  J Neural Eng       Date:  2015-01-21       Impact factor: 5.379

7.  Chronic electrical stimulation of peripheral nerves via deep-red light transduced by an implanted organic photocapacitor.

Authors:  Malin Silverå Ejneby; Marie Jakešová; Jose J Ferrero; Ludovico Migliaccio; Ihor Sahalianov; Zifang Zhao; Magnus Berggren; Dion Khodagholy; Vedran Đerek; Jennifer N Gelinas; Eric Daniel Głowacki
Journal:  Nat Biomed Eng       Date:  2021-12-16       Impact factor: 29.234

Review 8.  Spinal primitives and intra-spinal micro-stimulation (ISMS) based prostheses: a neurobiological perspective on the "known unknowns" in ISMS and future prospects.

Authors:  Simon F Giszter
Journal:  Front Neurosci       Date:  2015-03-20       Impact factor: 4.677

9.  In Vivo Demonstration of Addressable Microstimulators Powered by Rectification of Epidermically Applied Currents for Miniaturized Neuroprostheses.

Authors:  Laura Becerra-Fajardo; Antoni Ivorra
Journal:  PLoS One       Date:  2015-07-06       Impact factor: 3.240

Review 10.  Biomedical Implants with Charge-Transfer Monitoring and Regulating Abilities.

Authors:  Donghui Wang; Ji Tan; Hongqin Zhu; Yongfeng Mei; Xuanyong Liu
Journal:  Adv Sci (Weinh)       Date:  2021-06-24       Impact factor: 16.806

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.