Literature DB >> 19945121

Minimally invasive versus conventional mitral valve surgery: a propensity-matched comparison.

Lars G Svensson1, Fernando A Atik, Delos M Cosgrove, Eugene H Blackstone, Jeevanantham Rajeswaran, Gita Krishnaswamy, Ung Jin, A Marc Gillinov, Brian Griffin, José L Navia, Tomislav Mihaljevic, Bruce W Lytle.   

Abstract

OBJECTIVE: Less invasive approaches to mitral valve surgery are increasingly used for improved cosmesis; however, few studies have investigated their effect on outcome. We sought to compare these minimally invasive approaches fairly with conventional full sternotomy by using propensity-matching methods.
METHODS: From January 1995 to January 2004, 2124 patients underwent isolated mitral valve surgery through a minimally invasive approach, and 1047 underwent isolated mitral valve surgery through a conventional sternotomy. Because there were important differences in patient characteristics, a propensity score based on 42 factors was used to obtain 590 well-matched patient pairs (56% of cases).
RESULTS: In-hospital mortality was similar for propensity-matched patients: 0.17% (1/590) for those undergoing minimally invasive surgery and 0.85% (5/590) for those undergoing conventional surgery (P = .2). Occurrences of stroke (P = .8), renal failure (P > .9), myocardial infarction (P = .7), and infection (P = .8) were also similar. However, 24-hour mediastinal drainage was less after minimally invasive surgery (median, 250 vs 350 mL; P < .0001), and fewer patients received transfusions (30% vs 37%, P = .01). More patients undergoing minimally invasive surgery were extubated in the operating room (18% vs 5.7%, P < .0001), and postoperative forced expiratory volume in 1 second was higher. Early after operation, pain scores were lower (P < .0001) after minimally invasive surgery.
CONCLUSION: Within that portion of the spectrum of mitral valve surgery in which propensity matching was possible, minimally invasive mitral valve surgery had cosmetic, blood product use, respiratory, and pain advantages over conventional surgery, and no apparent detriments. Mortality and morbidity for robotic and percutaneous procedures should be compared with these minimally invasive outcomes. Copyright 2010. Published by Mosby, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19945121     DOI: 10.1016/j.jtcvs.2009.09.038

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  36 in total

Review 1.  Minimally invasive heart valve surgery: how and why in 2012.

Authors:  Rakesh M Suri; Nassir M Thalji
Journal:  Curr Cardiol Rep       Date:  2012-04       Impact factor: 2.931

2.  Robotic mitral valve repair for all categories of leaflet prolapse: improving patient appeal and advancing standard of care.

Authors:  Rakesh M Suri; Harold M Burkhart; Kent H Rehfeldt; Maurice Enriquez-Sarano; Richard C Daly; Eric E Williamson; Zhuo Li; Hartzell V Schaff
Journal:  Mayo Clin Proc       Date:  2011-07-14       Impact factor: 7.616

Review 3.  Minimally invasive aortic valve replacement surgery through lower half sternotomy.

Authors:  James R Fenton; John R Doty
Journal:  J Thorac Dis       Date:  2013-11       Impact factor: 2.895

4.  Minimally invasive mitral valve surgery is associated with excellent resource utilization, cost, and outcomes.

Authors:  Robert B Hawkins; J Hunter Mehaffey; Samuel M Kessel; Jolian J Dahl; Irving L Kron; John A Kern; Leora T Yarboro; Gorav Ailawadi
Journal:  J Thorac Cardiovasc Surg       Date:  2018-04-03       Impact factor: 5.209

5.  Propensity-matched analysis of minimally invasive mitral valve repair using a nationwide surgical database.

Authors:  Hiroyuki Nishi; Hiroaki Miyata; Noboru Motomura; Koichi Toda; Shigeru Miyagawa; Yoshiki Sawa; Shinichi Takamoto
Journal:  Surg Today       Date:  2015-06-27       Impact factor: 2.549

Review 6.  Complex robotic correction for complex degenerative mitral valve disease.

Authors:  Danny Ramzy; Joshua Chung; Wen Cheng; Michele A De Robertis; James Mirocha; Alfredo Trento
Journal:  Ann Cardiothorac Surg       Date:  2017-01

7.  Intramedullary reinforcement of sternal fixation with autologous xiphoid tenon.

Authors:  Jen-Ping Chang
Journal:  J Thorac Dis       Date:  2018-01       Impact factor: 2.895

8.  A minimally invasive approach is more cost-effective than a traditional sternotomy approach for mitral valve surgery.

Authors:  Alexander Iribarne; Rachel Easterwood; Mark J Russo; Y Claire Wang; Jonathan Yang; Kimberly N Hong; Craig R Smith; Michael Argenziano
Journal:  J Thorac Cardiovasc Surg       Date:  2011-06-14       Impact factor: 5.209

9.  Minimally invasive approach provides at least equivalent results for surgical correction of mitral regurgitation: a propensity-matched comparison.

Authors:  Andrew B Goldstone; Pavan Atluri; Wilson Y Szeto; Alen Trubelja; Jessica L Howard; John W MacArthur; Craig Newcomb; Joseph P Donnelly; Dale M Kobrin; Mary A Sheridan; Christiana Powers; Robert C Gorman; Joseph H Gorman; Alberto Pochettino; Joseph E Bavaria; Michael A Acker; W Clark Hargrove; Y Joseph Woo
Journal:  J Thorac Cardiovasc Surg       Date:  2013-03       Impact factor: 5.209

10.  Is minimally invasive thoracoscopic surgery the new benchmark for treating mitral valve disease?

Authors:  Andrew B Goldstone; Y Joseph Woo
Journal:  Ann Cardiothorac Surg       Date:  2016-11