Literature DB >> 19931014

Dosimetric impact of intrafractional patient motion in pediatric brain tumor patients.

Chris Beltran1, John Trussell, Thomas E Merchant.   

Abstract

The purpose of this study was to determine the dosimetric consequences of intrafractional patient motion on the clinical target volume (CTV), spinal cord, and optic nerves for non-sedated pediatric brain tumor patients. The patients were immobilized for treatment using a customized thermoplastic full-face mask and bite-block attached to an array of reflectors. The array was optically tracked by infra-red cameras at a frequency of 10 Hz. Patients were localized based on skin/mask marks and weekly films were taken to ensure proper setup. Before each noncoplanar field was delivered, the deviation from baseline of the array was recorded. The systematic error (SE) and random error (RE) were calculated. Direct simulation of the intrafractional motion was used to quantify the dosimetric changes to the targets and critical structures. Nine patients utilizing the optical tracking system were evaluated. The patient cohort had a mean of 31 +/- 1.5 treatment fractions; motion data were acquired for a mean of 26 +/- 6.2 fractions. The mean age was 15.6 +/- 4.1 years. The SE and RE were 0.4 and 1.1 mm in the posterior-anterior, 0.5 and 1.0 mm in left-right, and 0.6 and 1.3 mm in superior-inferior directions, respectively. The dosimetric effects of the motion on the CTV were negligible; however, the dose to the critical structures was increased. Patient motion during treatment does affect the dose to critical structures, therefore, planning risk volumes are needed to properly assess the dose to normal tissues. Because the motion did not affect the dose to the CTV, the 3-mm PTV margin used is sufficient to account for intrafractional motion, given the patient is properly localized at the start of treatment. Copyright 2010 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19931014      PMCID: PMC3800030          DOI: 10.1016/j.meddos.2009.01.004

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  32 in total

1.  Quantization of setup uncertainties in 3-D dose calculations.

Authors:  A E Lujan; R K Ten Haken; E W Larsen; J M Balter
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Inclusion of geometric uncertainties in treatment plan evaluation.

Authors:  Marcel van Herk; Peter Remeijer; Joos V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-04-01       Impact factor: 7.038

3.  Margins for translational and rotational uncertainties: a probability-based approach.

Authors:  Peter Remeijer; Coen Rasch; Joos V Lebesque; Marcel van Herk
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-06-01       Impact factor: 7.038

4.  Margins for geometric uncertainty around organs at risk in radiotherapy.

Authors:  Alan McKenzie; Marcel van Herk; Ben Mijnheer
Journal:  Radiother Oncol       Date:  2002-03       Impact factor: 6.280

5.  Intensity-modulated radiation therapy for pediatric medulloblastoma: early report on the reduction of ototoxicity.

Authors:  Eugene Huang; Bin S Teh; Douglas R Strother; Quillin G Davis; J Kam Chiu; Hsin H Lu; L Steven Carpenter; Wei Yuan Mai; Murali M Chintagumpala; Michael South; Walter H Grant; E Brian Butler; Shiao Y Woo
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-03-01       Impact factor: 7.038

6.  The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy.

Authors:  L A Dawson; K K Brock; S Kazanjian; D Fitch; C J McGinn; T S Lawrence; R K Ten Haken; J Balter
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-12-01       Impact factor: 7.038

7.  Image localization for frameless stereotactic radiotherapy.

Authors:  S L Meeks; F J Bova; T H Wagner; J M Buatti; W A Friedman; K D Foote
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-03-15       Impact factor: 7.038

8.  Comparison of two immobilization techniques using portal film and digitally reconstructed radiographs for pediatric patients with brain tumors.

Authors:  Y Zhu; J Stovall; L Butler; Q Ji; M W Gaber; S Samant; M R Sontag; A J de Armendi; T E Merchant
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-11-01       Impact factor: 7.038

9.  Accuracy of a relocatable stereotactic radiotherapy head frame evaluated by use of a depth helmet.

Authors:  K E Burton; S J Thomas; D Whitney; D S Routsis; R J Benson; N G Burnet
Journal:  Clin Oncol (R Coll Radiol)       Date:  2002-02       Impact factor: 4.126

10.  PTV margin determination in conformal SRT of intracranial lesions.

Authors:  Brent C Parker; Almon S Shiu; Moshe H Maor; Frederick F Lang; H Helen Liu; R Allen White; John A Antolak
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

View more
  5 in total

1.  Dosimetric consequences of rotational errors in radiation therapy of pediatric brain tumor patients.

Authors:  Chris Beltran; Alexander Pegram; Thomas E Merchant
Journal:  Radiother Oncol       Date:  2011-07-02       Impact factor: 6.280

2.  Inter- and intrafractional positional uncertainties in pediatric radiotherapy patients with brain and head and neck tumors.

Authors:  Chris Beltran; Matthew J Krasin; Thomas E Merchant
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-03       Impact factor: 7.038

3.  Surface-guided tomotherapy improves positioning and reduces treatment time: A retrospective analysis of 16 835 treatment fractions.

Authors:  André Haraldsson; Sofie Ceberg; Crister Ceberg; Sven Bäck; Silke Engelholm; Per E Engström
Journal:  J Appl Clin Med Phys       Date:  2020-06-26       Impact factor: 2.102

4.  Single Fraction Frameless Stereotactic Radiosurgery on the Gamma Knife Icon for Patients With Brain Metastases: Time to Abandon the Frame?

Authors:  Rodney E Wegner; Zachary D Horne; Yun Liang; Matthew Goss; Alexander Yu; Jonathan Pace; Richard W Williamson; Jody Leonardo; Stephen M Karlovits; Russel Fuhrer
Journal:  Adv Radiat Oncol       Date:  2021-06-06

5.  Improvement of therapeutic index for brain tumors with daily image guidance.

Authors:  Lisa Be Shields; James M Coons; Catherine Dedich; Maria Ragains; Kristi Scalf; Todd W Vitaz; Aaron C Spalding
Journal:  Radiat Oncol       Date:  2013-12-02       Impact factor: 3.481

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.