Quantization of setup uncertainties in 3-D dose calculations.

A E Lujan1, R K Ten Haken, E W Larsen, J M Balter.   

Abstract

Random setup errors can lead to erroneous prediction of the dose distribution calculated for a patient using a static computed tomography (CT) model. Multiple recomputations of the dose distribution covering the range of expected patient positions provides a way to estimate a course of treatment. However, due to the statistical nature of the setup uncertainties, many courses of treatment must be simulated to calculate a distribution of average dose values delivered to a patient. Thus, direct simulation methods can be time consuming and may be impractical for routine clinical treatment planning applications. Methods have been proposed to efficiently calculate the distribution of average dose values via a convolution of the dose distribution (calculated on a static CT model) with a probability distribution function (generally Gaussian) that describes the nature of the uncertainty. In this paper, we extend the convolution-based calculation to calculate the standard deviation of potential outcomes sigmaD(x,y,z) about the distribution of average dose values, and we characterize the statistical significance of this quantity using the central limit theorem. For an example treatment plan based on a treatment protocol in use at our institution, we found that there is a 68% probability that the actual dose delivered to any point (x,y,z) will be within 3% of the average dose value at that point. The standard deviation also yields confidence limits on the dose distribution, and these may be used to evaluate treatment plan stability.

Entities:  

Mesh:

Year:  1999        PMID: 10587223     DOI: 10.1118/1.598756

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Evaluation of dosimetric margins in prostate IMRT treatment plans.

Authors:  J J Gordon; J V Siebers
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

2.  A distance to dose difference tool for estimating the required spatial accuracy of a displacement vector field.

Authors:  Nahla K Saleh-Sayah; Elisabeth Weiss; Francisco J Salguero; Jeffrey V Siebers
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

3.  Dosimetric impact of intrafractional patient motion in pediatric brain tumor patients.

Authors:  Chris Beltran; John Trussell; Thomas E Merchant
Journal:  Med Dosim       Date:  2009-02-07       Impact factor: 1.482

4.  A systematic approach to statistical analysis in dosimetry and patient-specific IMRT plan verification measurements.

Authors:  Songbing Qin; Miao Zhang; Sung Kim; Ting Chen; Leonard H Kim; Bruce G Haffty; Ning J Yue
Journal:  Radiat Oncol       Date:  2013-09-30       Impact factor: 3.481

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.