Thermal infrared imaging: a novel method to monitor airflow during polysomnography.

Jayasimha N Murthy1, Johan van Jaarsveld, Jin Fei, Ioannis Pavlidis, Rajesh I Harrykissoon, Joseph F Lucke, Saadia Faiz, Richard J Castriotta.   

Abstract

STUDY
OBJECTIVES: This is a feasibility study designed to evaluate the accuracy of thermal infrared imaging (TIRI) as a noncontact method to monitor airflow during polysomnography and to ascertain the chance-corrected agreement (K) between TIRI and conventional airflow channels (nasal pressure [Pn], oronasal thermistor and expired CO2 [P(E)CO2]) in the detection of apnea and hypopnea.
DESIGN: Subjects were recruited to undergo polysomnography for 1 to 2 hours, during which simultaneous recordings from electroencephalography, electrooculography, electromyography, respiratory impedance plethysmography, conventional airflow channels, and TIRI were obtained.
SETTING: University-affiliated, American Academy of Sleep Medicine-accredited sleep disorders center. PATIENTS OR PARTICIPANTS: Fourteen volunteers without a history of sleep disordered breathing and 13 patients with a history of obstructive sleep apnea were recruited. MEASUREMENTS AND
RESULTS: In the detection of apnea and hypopnea, excellent agreement was noted between TIRI and thermistor (kappa = 0.92, Bayesian Credible Interval [BCI] 0.86, 0.96; pkappa = 0.99). Good agreement was noted between TIRI and Pn (kappa = 0.83, BCI 0.70, 0.90; pkappa = 0.98) and between TIRI and P(E)CO2 (kappa = 0.80, BCI 0.66, 0.89; pkappa = 0.94).
CONCLUSIONS: TIRI is a feasible noncontact technology to monitor airflow during polysomnography. In its current methodologic incarnation, it demonstrates a high degree of chance-corrected agreement with the oronasal thermistor in the detection of apnea and hypopneas but demonstrates a lesser degree of chance-corrected agreement with Pn. Further overnight validation studies must be performed to evaluate its potential in clinical sleep medicine.

Entities:  

Mesh:

Year:  2009        PMID: 19928392      PMCID: PMC2768959          DOI: 10.1093/sleep/32.11.1521

Source DB:  PubMed          Journal:  Sleep        ISSN: 0161-8105            Impact factor:   5.849


  10 in total

Review 1.  Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force.

Authors: 
Journal:  Sleep       Date:  1999-08-01       Impact factor: 5.849

2.  Proposed supplements and amendments to 'A Manual of Standardized Terminology, Techniques and Scoring System for Sleep Stages of Human Subjects', the Rechtschaffen & Kales (1968) standard.

Authors:  T Hori; Y Sugita; E Koga; S Shirakawa; K Inoue; S Uchida; H Kuwahara; M Kousaka; T Kobayashi; Y Tsuji; M Terashima; K Fukuda; N Fukuda
Journal:  Psychiatry Clin Neurosci       Date:  2001-06       Impact factor: 5.188

3.  Noncontact measurement of breathing function.

Authors:  Ramya Murthy; Ioannis Pavlidis
Journal:  IEEE Eng Med Biol Mag       Date:  2006 May-Jun

4.  Virtual thermistor.

Authors:  Jin Fei; Ioannis Pavlidis
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2007

5.  Sleep in the laboratory and sleep at home: comparisons of older insomniacs and normal sleepers.

Authors:  J D Edinger; A I Fins; R J Sullivan; G R Marsh; D S Dailey; T V Hope; M Young; E Shaw; D Carlson; D Vasilas
Journal:  Sleep       Date:  1997-12       Impact factor: 5.849

6.  The effect of polysomnography on sleep position: possible implications on the diagnosis of positional obstructive sleep apnea.

Authors:  M L Metersky; R J Castriotta
Journal:  Respiration       Date:  1996       Impact factor: 3.580

7.  Accuracy of nasal cannula pressure recordings for assessment of ventilation during sleep.

Authors:  R Thurnheer; X Xie; K E Bloch
Journal:  Am J Respir Crit Care Med       Date:  2001-11-15       Impact factor: 21.405

8.  The first night effect: an EEG study of sleep.

Authors:  H W Agnew; W B Webb; R L Williams
Journal:  Psychophysiology       Date:  1966-01       Impact factor: 4.016

9.  Prevalence and consequences of sleep disorders in traumatic brain injury.

Authors:  Richard J Castriotta; Mark C Wilde; Jenny M Lai; Strahil Atanasov; Brent E Masel; Samuel T Kuna
Journal:  J Clin Sleep Med       Date:  2007-06-15       Impact factor: 4.062

10.  Validation of nasal pressure for the identification of apneas/hypopneas during sleep.

Authors:  Steven J Heitman; Raj S Atkar; Eric A Hajduk; Richard A Wanner; W Ward Flemons
Journal:  Am J Respir Crit Care Med       Date:  2002-08-01       Impact factor: 21.405

  10 in total
  15 in total

Review 1.  Seizure detection: do current devices work? And when can they be useful?

Authors:  Xiuhe Zhao; Samden D Lhatoo
Journal:  Curr Neurol Neurosci Rep       Date:  2018-05-23       Impact factor: 5.081

2.  Noncontact spirometry with a webcam.

Authors:  Chenbin Liu; Yuting Yang; Francis Tsow; Dangdang Shao; Nongjian Tao
Journal:  J Biomed Opt       Date:  2017-05-01       Impact factor: 3.170

3.  Validation of a non-contact screening device for the combination of sleep-disordered breathing and periodic limb movements in sleep.

Authors:  Gerhard Weinreich; Sarah Terjung; Yi Wang; Stefanie Werther; Alberto Zaffaroni; Helmut Teschler
Journal:  Sleep Breath       Date:  2017-08-18       Impact factor: 2.816

Review 4.  Advancements in Methods and Camera-Based Sensors for the Quantification of Respiration.

Authors:  Haythem Rehouma; Rita Noumeir; Sandrine Essouri; Philippe Jouvet
Journal:  Sensors (Basel)       Date:  2020-12-17       Impact factor: 3.576

5.  New concept using Passive Infrared (PIR) technology for a contactless detection of breathing movement: a pilot study involving a cohort of 169 adult patients.

Authors:  V Hers; D Corbugy; I Joslet; P Hermant; J Demarteau; B Delhougne; G Vandermoten; J P Hermanne
Journal:  J Clin Monit Comput       Date:  2013-04-03       Impact factor: 2.502

6.  A novel method for extracting respiration rate and relative tidal volume from infrared thermography.

Authors:  Gregory F Lewis; Rodolfo G Gatto; Stephen W Porges
Journal:  Psychophysiology       Date:  2011-01-07       Impact factor: 4.016

7.  Antero-cervical thermophysiological characterization of obstructive sleep apnea patients.

Authors:  Mariana Jarnalo; Ricardo Vardasca; Joaquim Gabriel Mendes; Marta Drummond
Journal:  Sleep Breath       Date:  2018-02-23       Impact factor: 2.816

8.  Neonatal non-contact respiratory monitoring based on real-time infrared thermography.

Authors:  Abbas K Abbas; Konrad Heimann; Katrin Jergus; Thorsten Orlikowsky; Steffen Leonhardt
Journal:  Biomed Eng Online       Date:  2011-10-20       Impact factor: 2.819

Review 9.  Thermal Infrared Imaging-Based Computational Psychophysiology for Psychometrics.

Authors:  Daniela Cardone; Paola Pinti; Arcangelo Merla
Journal:  Comput Math Methods Med       Date:  2015-08-03       Impact factor: 2.238

10.  Intelligent neonatal monitoring based on a virtual thermal sensor.

Authors:  Abbas K Abbas; Steffen Leonhardt
Journal:  BMC Med Imaging       Date:  2014-03-02       Impact factor: 1.930

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.