Literature DB >> 28514470

Noncontact spirometry with a webcam.

Chenbin Liu1, Yuting Yang1, Francis Tsow1, Dangdang Shao1, Nongjian Tao2.   

Abstract

We present an imaging-based method for noncontact spirometry. The method tracks the subtle respiratory-induced shoulder movement of a subject, builds a calibration curve, and determines the flow-volume spirometry curve and vital respiratory parameters, including forced expiratory volume in the first second, forced vital capacity, and peak expiratory flow rate. We validate the accuracy of the method by comparing the data with those simultaneously recorded with a gold standard reference method and examine the reliability of the noncontact spirometry with a pilot study including 16 subjects. This work demonstrates that the noncontact method can provide accurate and reliable spirometry tests with a webcam. Compared to the traditional spirometers, the present noncontact spirometry does not require using a spirometer, breathing into a mouthpiece, or wearing a nose clip, thus making spirometry test more easily accessible for the growing population of asthma and chronic obstructive pulmonary diseases.

Entities:  

Mesh:

Year:  2017        PMID: 28514470      PMCID: PMC5435829          DOI: 10.1117/1.JBO.22.5.057002

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  18 in total

1.  A video-based optical system for rapid measurements of chest wall movement.

Authors:  G B Drummond; N D Duffy
Journal:  Physiol Meas       Date:  2001-08       Impact factor: 2.833

2.  Evaluation of chest motion and volumetry during the breathing cycle by dynamic MRI in healthy subjects: comparison with pulmonary function tests.

Authors:  Christian Plathow; Sebastian Ley; Christian Fink; Michael Puderbach; Melanie Heilmann; Ivan Zuna; Hans-Ulrich Kauczor
Journal:  Invest Radiol       Date:  2004-04       Impact factor: 6.016

3.  Advancements in noncontact, multiparameter physiological measurements using a webcam.

Authors:  Ming-Zher Poh; Daniel J McDuff; Rosalind W Picard
Journal:  IEEE Trans Biomed Eng       Date:  2010-10-14       Impact factor: 4.538

4.  Standardisation of spirometry.

Authors:  M R Miller; J Hankinson; V Brusasco; F Burgos; R Casaburi; A Coates; R Crapo; P Enright; C P M van der Grinten; P Gustafsson; R Jensen; D C Johnson; N MacIntyre; R McKay; D Navajas; O F Pedersen; R Pellegrino; G Viegi; J Wanger
Journal:  Eur Respir J       Date:  2005-08       Impact factor: 16.671

5.  Noncontact measurement of breathing function.

Authors:  Ramya Murthy; Ioannis Pavlidis
Journal:  IEEE Eng Med Biol Mag       Date:  2006 May-Jun

6.  Tracking in low frame rate video: a cascade particle filter with discriminative observers of different life spans.

Authors:  Yuan Li; Haizhou Ai; Takayoshi Yamashita; Shihong Lao; Masato Kawade
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2008-10       Impact factor: 6.226

7.  Noninvasive respiratory monitoring system based on the piezoceramic transducer's pyroelectric effect.

Authors:  Y P Huang; M S Young; C C Tai
Journal:  Rev Sci Instrum       Date:  2008-03       Impact factor: 1.523

8.  Estimates of ventilation from body surface measurements in unrestrained subjects.

Authors:  F D McCool; K B Kelly; S H Loring; I A Greaves; J Mead
Journal:  J Appl Physiol (1985)       Date:  1986-09

9.  Rib cage mechanics during quiet breathing and exercise in humans.

Authors:  C M Kenyon; S J Cala; S Yan; A Aliverti; G Scano; R Duranti; A Pedotti; P T Macklem
Journal:  J Appl Physiol (1985)       Date:  1997-10

10.  Surface chest motion decomposition for cardiovascular monitoring.

Authors:  Ghufran Shafiq; Kalyana C Veluvolu
Journal:  Sci Rep       Date:  2014-05-28       Impact factor: 4.379

View more
  3 in total

1.  Respiratory function assessment at the time of a new respiratory virus pandemic.

Authors:  Antonella LoMauro; Fabrizio Gervasoni; Arnaldo Andreoli; Andrea Aliverti
Journal:  Respir Med       Date:  2021-08-10       Impact factor: 4.582

2.  Standardization of Spirometry 2019 Update. An Official American Thoracic Society and European Respiratory Society Technical Statement.

Authors:  Brian L Graham; Irene Steenbruggen; Martin R Miller; Igor Z Barjaktarevic; Brendan G Cooper; Graham L Hall; Teal S Hallstrand; David A Kaminsky; Kevin McCarthy; Meredith C McCormack; Cristine E Oropez; Margaret Rosenfeld; Sanja Stanojevic; Maureen P Swanney; Bruce R Thompson
Journal:  Am J Respir Crit Care Med       Date:  2019-10-15       Impact factor: 21.405

Review 3.  Contactless Vital Signs Monitoring From Videos Recorded With Digital Cameras: An Overview.

Authors:  Nunzia Molinaro; Emiliano Schena; Sergio Silvestri; Fabrizio Bonotti; Damiano Aguzzi; Erika Viola; Fabio Buccolini; Carlo Massaroni
Journal:  Front Physiol       Date:  2022-02-18       Impact factor: 4.566

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.