Literature DB >> 11734446

Accuracy of nasal cannula pressure recordings for assessment of ventilation during sleep.

R Thurnheer1, X Xie, K E Bloch.   

Abstract

Nasal prong pressure monitoring (PNOSE) is utilized to assess ventilation during sleep. However, it has not been rigorously validated against the gold standard of face-mask pneumotachography (VFM). Therefore, we compared PNOSE with VFM in 20 patients with suspected sleep apnea during nocturnal polysomnography, and analyzed factors affecting accuracy of PNOSE-derived variables. Patients rated their nasal obstruction on a visual analog scale. Mean +/- SE apnea/hypopnea index (AHI) by VFM was 24.0 +/- 5.1 h(-1). The bias (mean difference) and limits of agreement (+/- 2 SD) of AHI derived from PNOSE, and square root-transformed PNOSE, a measure proposed as a surrogate of airflow, were +3.9 (+/- 4.6), and -0.9 (+/- 9.0) h(-1). Subjective scores of nasal obstruction before polysomnographies did not herald inaccuracy of AHI from PNOSE. Square root-transformed PNOSE closely tracked pneumotachographic airflow over 10 breaths (r(2) among signals 0.88 to 0.96) but the relationship among these signals was highly variable if comparisons were extended over an entire night. Compared with face-mask pneumotachography, nasal pressure monitoring provides accurate AHI for clinical purposes even in patients perceiving nasal obstruction. Square-root transformation provides near linear nasal pressure/airflow relationships over a short time but is not essential for estimation of AHI.

Entities:  

Mesh:

Year:  2001        PMID: 11734446     DOI: 10.1164/ajrccm.164.10.2102104

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  33 in total

Review 1.  Sleep . 3: Clinical presentation and diagnosis of the obstructive sleep apnoea hypopnoea syndrome.

Authors:  D Schlosshan; M W Elliott
Journal:  Thorax       Date:  2004-04       Impact factor: 9.139

2.  Home Portable Sleep Testing Has Gone Global.

Authors:  Karel Calero; William McDowell Anderson
Journal:  J Clin Sleep Med       Date:  2016-01       Impact factor: 4.062

3.  Validation of a polyvinylidene fluoride impedance sensor for respiratory event classification during polysomnography.

Authors:  Brian B Koo; Colin Drummond; Susan Surovec; Nathan Johnson; Stephanie A Marvin; Susan Redline
Journal:  J Clin Sleep Med       Date:  2011-10-15       Impact factor: 4.062

4.  Use of Chest Wall EMG to Classify Hypopneas as Obstructive or Central.

Authors:  Richard B Berry; Scott Ryals; Mary H Wagner
Journal:  J Clin Sleep Med       Date:  2018-05-15       Impact factor: 4.062

Review 5.  Diagnostic issues in pediatric obstructive sleep apnea.

Authors:  Hiren Muzumdar; Raanan Arens
Journal:  Proc Am Thorac Soc       Date:  2008-02-15

6.  A procedure for determining subject-specific pulse oxygen saturation response.

Authors:  Kyle M Burk; Joseph A Orr
Journal:  Med Biol Eng Comput       Date:  2020-01-27       Impact factor: 2.602

7.  Inspiratory flow limitation in a normal population of adults in São Paulo, Brazil.

Authors:  Luciana O Palombini; Sergio Tufik; David M Rapoport; Indu A Ayappa; Christian Guilleminault; Luciana B M de Godoy; Laura S Castro; Lia Bittencourt
Journal:  Sleep       Date:  2013-11-01       Impact factor: 5.849

8.  Polysomnographic determinants of nocturnal hypercapnia in patients with sleep apnea.

Authors:  Nattapong Jaimchariyatam; Raed A Dweik; Roop Kaw; Loutfi S Aboussouan
Journal:  J Clin Sleep Med       Date:  2013-03-15       Impact factor: 4.062

9.  Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine.

Authors:  Richard B Berry; Rohit Budhiraja; Daniel J Gottlieb; David Gozal; Conrad Iber; Vishesh K Kapur; Carole L Marcus; Reena Mehra; Sairam Parthasarathy; Stuart F Quan; Susan Redline; Kingman P Strohl; Sally L Davidson Ward; Michelle M Tangredi
Journal:  J Clin Sleep Med       Date:  2012-10-15       Impact factor: 4.062

10.  Validation of a novel device to objectively measure adherence to long-term oxygen therapy.

Authors:  Sun-Kai V Lin; Daniel K Bogen; Samuel T Kuna
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2008
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.