Literature DB >> 19923043

Fast exact/quasi-exact FBP algorithms for triple-source helical cone-beam CT.

Yang Lu1, Alexander Katsevich, Jun Zhao, Hengyong Yu, Ge Wang.   

Abstract

Cardiac computed tomography (CT) has been improved over past years, but it still needs improvement for higher temporal resolution in the cases of high or irregular cardiac rates. Given successful applications of dual-source cardiac CT scanners, triple-source cone-beam CT seems a promising mode for cardiac CT. In this paper, we propose two filtered-backprojection algorithms for triple-source helical cone-beam CT. The first algorithm utilizes two families of filtering lines. These lines are parallel to the tangent of the scanning trajectory and the so-called L lines. The second algorithm utilizes two families of filtering lines tangent to the boundaries of the Zhao window and L lines, respectively, but it eliminates the filtering paths along the tangent of the scanning trajectory, thus reducing the required detector size greatly. The first algorithm is theoretically exact for r < 0.265R and quasi-exact for 0.265R <or= r < 0.495R, and the second algorithm is quasi-exact for r < 0.495R , where r and R denote the object radius and the trajectory radius, respectively. Both algorithms are computationally efficient. Numerical results are presented to verify and showcase the proposed algorithms.

Entities:  

Mesh:

Year:  2009        PMID: 19923043      PMCID: PMC2885857          DOI: 10.1109/TMI.2009.2035617

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  11 in total

1.  Multirow detector and cone-beam spiral/helical CT.

Authors:  G Wang; C R Crawford; W A Kalender
Journal:  IEEE Trans Med Imaging       Date:  2000-09       Impact factor: 10.048

2.  Spiral CT refines imaging of temporal bone disorders.

Authors:  M W Vannier; G E Wang
Journal:  Diagn Imaging (San Franc)       Date:  1993-11

3.  Exact helical reconstruction using native cone-beam geometries.

Authors:  Frédéric Noo; Jed Pack; Dominic Heuscher
Journal:  Phys Med Biol       Date:  2003-12-07       Impact factor: 3.609

4.  Design, analysis and simulation for development of the first clinical micro-CT scanner.

Authors:  Ge Wang; Shiying Zhao; Hengyong Yu; Charles A Miller; Paul J Abbas; Bruce J Gantz; Seung Wook Lee; Jay T Rubinstein
Journal:  Acad Radiol       Date:  2005-04       Impact factor: 3.173

Review 5.  Approximate and exact cone-beam reconstruction with standard and non-standard spiral scanning.

Authors:  Ge Wang; Yangbo Ye; Hengyong Yu
Journal:  Phys Med Biol       Date:  2007-02-19       Impact factor: 3.609

6.  A general cone-beam reconstruction algorithm.

Authors:  G Wang; T H Lin; P Cheng; D M Shinozaki
Journal:  IEEE Trans Med Imaging       Date:  1993       Impact factor: 10.048

7.  Tiny a priori knowledge solves the interior problem in computed tomography.

Authors:  Hiroyuki Kudo; Matias Courdurier; Frédéric Noo; Michel Defrise
Journal:  Phys Med Biol       Date:  2008-04-09       Impact factor: 3.609

8.  First performance evaluation of a dual-source CT (DSCT) system.

Authors:  Thomas G Flohr; Cynthia H McCollough; Herbert Bruder; Martin Petersilka; Klaus Gruber; Christoph Süss; Michael Grasruck; Karl Stierstorfer; Bernhard Krauss; Rainer Raupach; Andrew N Primak; Axel Küttner; Stefan Achenbach; Christoph Becker; Andreas Kopp; Bernd M Ohnesorge
Journal:  Eur Radiol       Date:  2005-12-10       Impact factor: 5.315

9.  Multithreaded cardiac CT.

Authors:  Marc Kachelriess; Michael Knaup; Willi A Kalender
Journal:  Med Phys       Date:  2006-07       Impact factor: 4.071

10.  A general local reconstruction approach based on a truncated hilbert transform.

Authors:  Yangbo Ye; Hengyong Yu; Yuchuan Wei; Ge Wang
Journal:  Int J Biomed Imaging       Date:  2007
View more
  3 in total

1.  Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults.

Authors:  Gaurav S Desai; Raul N Uppot; Elaine W Yu; Avinash R Kambadakone; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2012-04-19       Impact factor: 5.315

2.  Completeness map evaluation demonstrated with candidate next-generation cardiac CT architectures.

Authors:  Baodong Liu; James Bennett; Ge Wang; Bruno De Man; Kai Zeng; Zhye Yin; Paul Fitzgerald; Hengyong Yu
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

3.  Comparative assessment of three image reconstruction techniques for image quality and radiation dose in patients undergoing abdominopelvic multidetector CT examinations.

Authors:  G S Desai; A Thabet; A Y A Elias; D V Sahani
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.