Literature DB >> 31742799

Robust outer volume suppression utilizing elliptical pulsed second order fields (ECLIPSE) for human brain proton MRSI.

Chathura Kumaragamage1, Henk M De Feyter1, Peter Brown1, Scott McIntyre1, Terence W Nixon1, Robin A de Graaf1,2.   

Abstract

PURPOSE: The robust and reliable utilization of proton magnetic resonance spectroscopic imaging (MRSI) at high fields is hampered by several key technical difficulties, including contamination from extracranial lipids. To that end, this work presents novel lipid suppression sequences for proton MRSI in the human brain utilizing elliptical localization with pulsed second-order fields (ECLIPSE).
METHODS: Two lipid suppression methods were implemented with the ECLIPSE gradient insert. One method is a variable power, 4-pulse sequence optimized to achieve outer volume suppression (OVS) and compared against a standard, 8-slice OVS method. The second ECLIPSE method is implemented as an inversion recovery (IR) sequence with elliptical inner volume selection (IVS) and compared against a global IR method.
RESULTS: The ECLIPSE-OVS sequence provided a 116-fold mean lipid suppression (range, 104-134), whereas an optimized 8-slice OVS sequence achieved 15-fold suppression (range, 13-18). Furthermore, the superior ECLIPSE-OVS suppression was achieved at 30% of the radiofrequency (RF) power required by 8-slice OVS. The ECLIPSE-based IR sequence suppressed skull lipids by 155-fold (range, 122-257), compared to 16-fold suppression (range, 14-19) achieved with IR.
CONCLUSION: OVS and IVS executed with ECLIPSE provide robust and effective lipid suppression at reduced RF power with high immunity to variations in B1 and T1 .
© 2019 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  ECLIPSE; human brain MRSI; lipids; outer volume suppression

Mesh:

Substances:

Year:  2019        PMID: 31742799      PMCID: PMC6982600          DOI: 10.1002/mrm.28047

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  42 in total

1.  Comparison of inversion recovery preparation schemes for lipid suppression in 1H MRSI of human brain.

Authors:  Andreas Ebel; Varanavasi Govindaraju; Andrew A Maudsley
Journal:  Magn Reson Med       Date:  2003-05       Impact factor: 4.668

2.  Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy.

Authors:  R J Ordidge; M Wylezinska; J W Hugg; E Butterworth; F Franconi
Journal:  Magn Reson Med       Date:  1996-10       Impact factor: 4.668

3.  Ultra-high resolution brain metabolite mapping at 7 T by short-TR Hadamard-encoded FID-MRSI.

Authors:  Gilbert Hangel; Bernhard Strasser; Michal Považan; Eva Heckova; Lukas Hingerl; Roland Boubela; Stephan Gruber; Siegfried Trattnig; Wolfgang Bogner
Journal:  Neuroimage       Date:  2016-11-04       Impact factor: 6.556

Review 4.  Spatial localization in NMR spectroscopy in vivo.

Authors:  P A Bottomley
Journal:  Ann N Y Acad Sci       Date:  1987       Impact factor: 5.691

5.  In vivo 1H NMR spectroscopy of rat brain at 1 ms echo time.

Authors:  I Tkác; Z Starcuk; I Y Choi; R Gruetter
Journal:  Magn Reson Med       Date:  1999-04       Impact factor: 4.668

6.  Elliptical localization with pulsed second-order fields (ECLIPSE) for robust lipid suppression in proton MRSI.

Authors:  Robin A de Graaf; Peter B Brown; Henk M De Feyter; Scott McIntyre; Terence W Nixon
Journal:  NMR Biomed       Date:  2018-07-09       Impact factor: 4.044

7.  Changes of hippocampal N-acetyl aspartate and volume in Alzheimer's disease. A proton MR spectroscopic imaging and MRI study.

Authors:  N Schuff; D Amend; F Ezekiel; S K Steinman; J Tanabe; D Norman; W Jagust; J H Kramer; J A Mastrianni; G Fein; M W Weiner
Journal:  Neurology       Date:  1997-12       Impact factor: 9.910

8.  Spin-echo magnetic resonance spectroscopic imaging at 7 T with frequency-modulated refocusing pulses.

Authors:  He Zhu; Brian J Soher; Ronald Ouwerkerk; Michael Schär; Peter B Barker
Journal:  Magn Reson Med       Date:  2012-06-12       Impact factor: 4.668

9.  7T MR spectroscopic imaging in the localization of surgical epilepsy.

Authors:  Jullie W Pan; Robert B Duckrow; Jason Gerrard; Caroline Ong; Lawrence J Hirsch; Stanley R Resor; Yan Zhang; Ognen Petroff; Susan Spencer; Hoby P Hetherington; Dennis D Spencer
Journal:  Epilepsia       Date:  2013-07-29       Impact factor: 5.864

10.  Multisection proton MR spectroscopic imaging of the brain.

Authors:  J H Duyn; J Gillen; G Sobering; P C van Zijl; C T Moonen
Journal:  Radiology       Date:  1993-07       Impact factor: 11.105

View more
  5 in total

Review 1.  In Vivo 13C Magnetic Resonance Spectroscopy for Assessing Brain Biochemistry in Health and Disease.

Authors:  Rimil Guha Roy; Avantika Samkaria; Pravat K Mandal; Joseph C Maroon; Yashika Arora
Journal:  Neurochem Res       Date:  2022-01-28       Impact factor: 3.996

2.  Whole-brain high-resolution metabolite mapping with 3D compressed-sensing SENSE low-rank 1 H FID-MRSI.

Authors:  Antoine Klauser; Paul Klauser; Frédéric Grouiller; Sébastien Courvoisier; François Lazeyras
Journal:  NMR Biomed       Date:  2021-10-01       Impact factor: 4.478

3.  ECLIPSE utilizing gradient-modulated offset-independent adiabaticity (GOIA) pulses for highly selective human brain proton MRSI.

Authors:  Chathura Kumaragamage; Henk M De Feyter; Peter Brown; Scott McIntyre; Terence W Nixon; Robin A de Graaf
Journal:  NMR Biomed       Date:  2020-10-01       Impact factor: 4.478

4.  Water and lipid suppression techniques for advanced 1 H MRS and MRSI of the human brain: Experts' consensus recommendations.

Authors:  Ivan Tkáč; Dinesh Deelchand; Wolfgang Dreher; Hoby Hetherington; Roland Kreis; Chathura Kumaragamage; Michal Považan; Daniel M Spielman; Bernhard Strasser; Robin A de Graaf
Journal:  NMR Biomed       Date:  2020-12-16       Impact factor: 4.478

5.  Proton metabolic mapping of the brain at 7 T using a two-dimensional free induction decay-echo-planar spectroscopic imaging readout with lipid suppression.

Authors:  Kyung Min Nam; Arjan D Hendriks; Vincent O Boer; Dennis W J Klomp; Jannie P Wijnen; Alex A Bhogal
Journal:  NMR Biomed       Date:  2022-05-26       Impact factor: 4.478

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.