Performance evaluation of a 32-element head array with respect to the ultimate intrinsic SNR.

Riccardo Lattanzi1, Aaron K Grant, Jonathan R Polimeni, Michael A Ohliger, Graham C Wiggins, Lawrence L Wald, Daniel K Sodickson.   

Abstract

The quality of an RF detector coil design is commonly judged on how it compares with other coil configurations. The aim of this article is to develop a tool for evaluating the absolute performance of RF coil arrays. An algorithm to calculate the ultimate intrinsic signal-to-noise ratio (SNR) was implemented for a spherical geometry. The same imaging tasks modeled in the calculations were reproduced experimentally using a 32-element head array. Coil performance maps were then generated based on the ratio of experimentally measured SNR to the ultimate intrinsic SNR, for different acceleration factors associated with different degrees of parallel imaging. The relative performance in all cases was highest near the center of the samples (where the absolute SNR was lowest). The highest performance was found in the unaccelerated case and a maximum of 85% was observed with a phantom whose electrical properties are consistent with values in the human brain. The performance remained almost constant for 2-fold acceleration, but deteriorated at higher acceleration factors, suggesting that larger arrays are needed for effective highly-accelerated parallel imaging. The method proposed here can serve as a tool for the evaluation of coil designs, as well as a tool to guide the development of original designs which may begin to approach the optimal performance. (c) 2009 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19904727      PMCID: PMC2830315          DOI: 10.1002/nbm.1435

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  19 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging.

Authors:  Jacco A de Zwart; Patrick J Ledden; Peter Kellman; Peter van Gelderen; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

4.  Ultimate intrinsic signal-to-noise ratio for parallel MRI: electromagnetic field considerations.

Authors:  Michael A Ohliger; Aaron K Grant; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

5.  Electrodynamics and ultimate SNR in parallel MR imaging.

Authors:  Florian Wiesinger; Peter Boesiger; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2004-08       Impact factor: 4.668

6.  Effects of inductive coupling on parallel MR image reconstructions.

Authors:  Michael A Ohliger; Patrick Ledden; Charles A McKenzie; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2004-09       Impact factor: 4.668

7.  Image brightening in samples of high dielectric constant.

Authors:  James Tropp
Journal:  J Magn Reson       Date:  2004-03       Impact factor: 2.229

8.  32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry.

Authors:  G C Wiggins; C Triantafyllou; A Potthast; A Reykowski; M Nittka; L L Wald
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

9.  The intrinsic signal-to-noise ratio in NMR imaging.

Authors:  W A Edelstein; G H Glover; C J Hardy; R W Redington
Journal:  Magn Reson Med       Date:  1986-08       Impact factor: 4.668

10.  Measurement of signal intensities in the presence of noise in MR images.

Authors:  R M Henkelman
Journal:  Med Phys       Date:  1985 Mar-Apr       Impact factor: 4.071

View more
  23 in total

1.  Investigation of multichannel phased array performance for fetal MR imaging on 1.5T clinical MR system.

Authors:  Ye Li; Yong Pang; Daniel Vigneron; Orit Glenn; Duan Xu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-01-01

2.  Brain imaging with improved acceleration and SNR at 7 Tesla obtained with 64-channel receive array.

Authors:  Kamil Uğurbil; Edward Auerbach; Steen Moeller; Andrea Grant; Xiaoping Wu; Pierre-Francois Van de Moortele; Cheryl Olman; Lance DelaBarre; Scott Schillak; Jerahmie Radder; Russell Lagore; Gregor Adriany
Journal:  Magn Reson Med       Date:  2019-02-25       Impact factor: 4.668

3.  Size-adaptable "Trellis" structure for tailored MRI coil arrays.

Authors:  Bei Zhang; Ryan Brown; Martijn Cloos; Riccardo Lattanzi; Daniel Sodickson; Graham Wiggins
Journal:  Magn Reson Med       Date:  2018-12-21       Impact factor: 4.668

4.  Approaching Ultimate Intrinsic SNR in a Uniform Spherical Sample with Finite Arrays of Loop Coils.

Authors:  Manushka V Vaidya; Daniel K Sodickson; Riccardo Lattanzi
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2014-08       Impact factor: 1.176

Review 5.  MRI evaluation and safety in the developing brain.

Authors:  Shannon Tocchio; Beth Kline-Fath; Emanuel Kanal; Vincent J Schmithorst; Ashok Panigrahy
Journal:  Semin Perinatol       Date:  2015-03-03       Impact factor: 3.300

6.  A formalism to investigate the optimal transmit efficiency in radiofrequency shimming.

Authors:  Ioannis P Georgakis; Athanasios G Polimeridis; Riccardo Lattanzi
Journal:  NMR Biomed       Date:  2020-07-28       Impact factor: 4.044

7.  Radiofrequency energy deposition and radiofrequency power requirements in parallel transmission with increasing distance from the coil to the sample.

Authors:  Cem M Deniz; Manushka V Vaidya; Daniel K Sodickson; Riccardo Lattanzi
Journal:  Magn Reson Med       Date:  2015-03-05       Impact factor: 4.668

8.  Design and application of combined 8-channel transmit and 10-channel receive arrays and radiofrequency shimming for 7-T shoulder magnetic resonance imaging.

Authors:  Ryan Brown; Cem Murat Deniz; Bei Zhang; Gregory Chang; Daniel K Sodickson; Graham C Wiggins
Journal:  Invest Radiol       Date:  2014-01       Impact factor: 6.016

9.  Effects of proximity and noise level of phased array coil elements on overall signal-to-noise in parallel MR spectroscopy.

Authors:  Candace C Fleischer; Xiaodong Zhong; Hui Mao
Journal:  Magn Reson Imaging       Date:  2017-12-05       Impact factor: 2.546

Review 10.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.