Literature DB >> 19902895

Reproducibility and accuracy of templating uncemented THA with digital radiographic and digital TraumaCad templating software.

Panamoottil G Anil Kumar1, Sayyied J Kirmani, Heike Humberg, Venu Kavarthapu, Patrick Li.   

Abstract

The reproducibility and accuracy of a digital software templating program on digital images was examined for primary uncemented total hip arthroplasty (THA). Forty-five patients waiting for an uncemented THA had templating performed of their digital picture archiving and communication systems (PACS) pelvic images with the TraumaCad software program (Orthocrat Ltd, Petach-Tikva, Israel). Acetabular cup size, femoral stem size, and femoral offset were noted by 2 observers, and again by 1 of the observers a week later. Through correlation coefficients and significance testing, the degree of intraobserver and interobserver variability was evaluated, as well as the level of accuracy for digital templating. Excellent correlation was found for all data sets, with no significant difference between them in intraobserver reproducibility. Also in terms of interobserver reproducibility, we found good levels of correlation, with no significant difference between the data sets. In terms of accuracy, the correlation was at least acceptable with no significant difference between any of the data sets. The use of the TraumaCad digital software program provides a reliable method of templating digital images for uncemented THAs. There is little intraobserver and interobserver variability, and the method produces an acceptable level of accuracy.

Entities:  

Mesh:

Year:  2009        PMID: 19902895     DOI: 10.3928/01477447-20090922-08

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  13 in total

1.  [Implant position of total hip arthroplasty shafts. Establishment of a new method for comparison between planned and achieved shaft positions].

Authors:  A Fottner; A Steinbrück; E Volkmer; F Haasters; F Mazoochian; V Jansson
Journal:  Orthopade       Date:  2012-07       Impact factor: 1.087

2.  Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study.

Authors:  Benjamin G Domb; Youssef F El Bitar; Adam Y Sadik; Christine E Stake; Itamar B Botser
Journal:  Clin Orthop Relat Res       Date:  2013-08-29       Impact factor: 4.176

3.  Templating in uncemented total hip arthroplasty-on intra- and interobserver reliability and professional experience.

Authors:  Nils J Strøm; Are Hugo Pripp; Olav Reikerås
Journal:  Ann Transl Med       Date:  2017-02

4.  How to best measure femoral length and lateralisation after total hip arthroplasty on antero-posterior pelvic radiographs.

Authors:  Nicolas Bonin; Laurent Jacquot; Laurent Boulard; Patrick Reynaud; Mo Saffarini; Sébastien Lustig
Journal:  Int Orthop       Date:  2016-03-01       Impact factor: 3.075

5.  Ceramic-on-ceramic total hip arthroplasty: incidence of instability and noise.

Authors:  David Schroder; Lindsey Bornstein; Mathias P G Bostrom; Bryan J Nestor; Douglas E Padgett; Geoffrey H Westrich
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

6.  Trabecular titanium cups in acetabular revision arthroplasty: analysis of 10-year survivorship, restoration of center of rotation and osteointegration.

Authors:  Andrea Cozzi Lepri; Matteo Innocenti; Alberto Galeotti; Christian Carulli; Marco Villano; Roberto Civinini
Journal:  Arch Orthop Trauma Surg       Date:  2021-11-15       Impact factor: 2.928

7.  Acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty.

Authors:  Robert Petretta; Jason Strelzow; Nicholas E Ohly; Peter Misur; Bassam A Masri
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

8.  Two year follow up of supercapsular percutaneously assisted total hip arthroplasty.

Authors:  Andrew Kay; Derek Klavas; Varan Haghshenas; Mimi Phan; Daniel Le
Journal:  BMC Musculoskelet Disord       Date:  2021-05-24       Impact factor: 2.362

9.  Accuracy and Reliability of Preoperative On-screen Templating Using Digital Radiographs for Total Hip Arthroplasty.

Authors:  Jong Ki Shin; Seung Min Son; Tae Woo Kim; Won Chul Shin; Jung Sub Lee; Kuen Tak Suh
Journal:  Hip Pelvis       Date:  2016-12-28

10.  Use of Acetate Templates Over Digital Radiographs for Templating in Total Hip Arthroplasty: Technique and Its Validation.

Authors:  Tarun Goyal; Siddharth S Sethy; Sajid Ansari; Lakshmana Das; Souvik Paul
Journal:  Indian J Orthop       Date:  2020-11-03       Impact factor: 1.251

View more