Literature DB >> 19891018

CO(2) insufflation for potentially difficult colonoscopies: efficacy when used by less experienced colonoscopists.

Toshio Uraoka1, Jun Kato, Motoaki Kuriyama, Keisuke Hori, Shin Ishikawa, Keita Harada, Koji Takemoto, Sakiko Hiraoka, Hideyuki Fujita, Joichiro Horii, Yutaka Saito, Kazuhide Yamamoto.   

Abstract

AIM: To clarify the effectiveness of CO(2) insufflation in potentially difficult colonoscopy cases, particularly in relation to the experience level of colonoscopists.
METHODS: One hundred twenty potentially difficult cases were included in this study, which involved females with a low body mass index and patients with earlier abdominal and/or pelvic open surgery or previously diagnosed left-side colon diverticulosis. Patients receiving colonoscopy examinations without sedation using a pediatric variable-stiffness colonoscope were divided into two groups based on either CO(2) or standard air insufflation. Both insufflation procedures were also evaluated according to the experience level of the respective colonoscopists who were divided into an experienced colonoscopist (EC) group and a less experienced colonoscopist (LEC) group. Study measurements included a 100-mm visual analogue scale (VAS) for patient pain during and after colonoscopy examinations, in addition to insertion to the cecum and withdrawal times.
RESULTS: Examination times did not differ, however, VAS scores in the CO(2) group were significantly better than in the air group (P < 0.001, two-way ANOVA) from immediately after the procedure and up to 2 h later. There were no significant differences between either insufflation method in the EC group (P = 0.29), however, VAS scores for CO(2) insufflation were significantly better than air insufflation in the LEC group (P = 0.023) immediately after colonoscopies and up to 4 h afterwards.
CONCLUSION: CO(2) insufflation reduced patient pain after colonoscopy in potentially difficult cases when performed by LECs. 2009 The WJG Press and Baishideng. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19891018      PMCID: PMC2773898          DOI: 10.3748/wjg.15.5186

Source DB:  PubMed          Journal:  World J Gastroenterol        ISSN: 1007-9327            Impact factor:   5.742


  35 in total

1.  A survey on gastroenterology training in Europe.

Authors:  R Bisschops; A Wilmer; J Tack
Journal:  Gut       Date:  2002-05       Impact factor: 23.059

2.  A new variable stiffness colonoscope makes colonoscopy easier: a randomised controlled trial.

Authors:  J C Brooker; B P Saunders; S G Shah; C B Williams
Journal:  Gut       Date:  2000-06       Impact factor: 23.059

3.  Effect of variable stiffness colonoscopes on cecal intubation times for routine colonoscopy by an experienced examiner in sedated patients.

Authors:  D K Rex
Journal:  Endoscopy       Date:  2001-01       Impact factor: 10.093

4.  Factors that predict incomplete colonoscopy: thinner is not always better.

Authors:  J C Anderson; J D Gonzalez; C R Messina; B J Pollack
Journal:  Am J Gastroenterol       Date:  2000-10       Impact factor: 10.864

5.  A randomized controlled trial in a training institution comparing a pediatric variable stiffness colonoscope, a pediatric colonoscope, and an adult colonoscope.

Authors:  Douglas A Shumaker; Atif Zaman; Ronald M Katon
Journal:  Gastrointest Endosc       Date:  2002-02       Impact factor: 9.427

6.  NORCCAP (Norwegian colorectal cancer prevention): a randomised trial to assess the safety and efficacy of carbon dioxide versus air insufflation in colonoscopy.

Authors:  M Bretthauer; E Thiis-Evensen; G Huppertz-Hauss; L Gisselsson; T Grotmol; E Skovlund; G Hoff
Journal:  Gut       Date:  2002-05       Impact factor: 23.059

7.  Procedural success and complications of large-scale screening colonoscopy.

Authors:  Douglas B Nelson; Kenneth R McQuaid; John H Bond; David A Lieberman; David G Weiss; Tiina K Johnston
Journal:  Gastrointest Endosc       Date:  2002-03       Impact factor: 9.427

8.  Factors affecting insertion time and patient discomfort during colonoscopy.

Authors:  W H Kim; Y J Cho; J Y Park; P K Min; J K Kang; I S Park
Journal:  Gastrointest Endosc       Date:  2000-11       Impact factor: 9.427

9.  Usefulness of a pediatric colonoscope for routine colonoscopy in women who have undergone hysterectomy.

Authors:  John B Marshall; Rodney A Perez; Richard W Madsen
Journal:  Gastrointest Endosc       Date:  2002-06       Impact factor: 9.427

10.  An adequate level of training for technical competence in screening and diagnostic colonoscopy: a prospective multicenter evaluation of the learning curve.

Authors:  Suck-Ho Lee; Il-Kwun Chung; Sun-Joo Kim; Jin-Oh Kim; Bong-Min Ko; Young Hwangbo; Won Ho Kim; Dong Hun Park; Sang Kil Lee; Cheol Hee Park; Il-Hyun Baek; Dong Il Park; Seun-Ja Park; Jeong-Seon Ji; Byung-Ik Jang; Yoon-Tae Jeen; Jeong Eun Shin; Jeong-Sik Byeon; Chang-Soo Eun; Dong Soo Han
Journal:  Gastrointest Endosc       Date:  2008-02-14       Impact factor: 9.427

View more
  12 in total

1.  The water exchange method and difficult colonoscopy.

Authors:  Felix W Leung; Yanglin Pan; Surinder K Mann; Joseph W Leung; Rodelei M Siao-Salera; Guy Jackson
Journal:  J Interv Gastroenterol       Date:  2012-07-01

2.  Safety and effectiveness of propofol sedation during and after outpatient colonoscopy.

Authors:  Akira Horiuchi; Yoshiko Nakayama; Masashi Kajiyama; Naoyuki Kato; Tetsuya Kamijima; Yasuyuki Ichise; Naoki Tanaka
Journal:  World J Gastroenterol       Date:  2012-07-14       Impact factor: 5.742

Review 3.  Is the type of insufflation a key issue in gastro-intestinal endoscopy?

Authors:  Amy C Lord; Stefan Riss
Journal:  World J Gastroenterol       Date:  2014-03-07       Impact factor: 5.742

4.  Feasibility and Importance of Enteroscopy after Gastric Bypass.

Authors:  Dean Keren; H Madi; I Matter; A Assalia; T Rainis
Journal:  Obes Surg       Date:  2017-05       Impact factor: 4.129

Review 5.  Colorectal endoscopic submucosal dissection: Recent technical advances for safe and successful procedures.

Authors:  Katsumi Yamamoto; Tomoki Michida; Tsutomu Nishida; Shiro Hayashi; Masafumi Naito; Toshifumi Ito
Journal:  World J Gastrointest Endosc       Date:  2015-10-10

6.  Clinical impact of endoscopy position detecting unit (UPD-3) for a non-sedated colonoscopy.

Authors:  Masakatsu Fukuzawa; Junichi Uematsu; Shin Kono; Sho Suzuki; Takemasa Sato; Naoko Yagi; Yuichiro Tsuji; Kenji Yagi; Chika Kusano; Takuji Gotoda; Takashi Kawai; Fuminori Moriyasu
Journal:  World J Gastroenterol       Date:  2015-04-28       Impact factor: 5.742

7.  Percutaneous endoscopic gastrostomy under steady pressure automatically controlled endoscopy: First clinical series.

Authors:  Hiroyuki Imaeda; Kiyokazu Nakajima; Naoki Hosoe; Masanori Nakahara; Shinichiro Zushi; Motohiko Kato; Kazuhiro Kashiwagi; Yasushi Matsumoto; Kayoko Kimura; Rieko Nakamura; Norihito Wada; Masahiko Tsujii; Naohisa Yahagi; Toshifumi Hibi; Takanori Kanai; Tetsuo Takehara; Haruhiko Ogata
Journal:  World J Gastrointest Endosc       Date:  2016-02-10

8.  DDW 2011 cutting edge colonoscopy techniques - state of the art lecture master class - warm water infusion/CO(2) insufflation for colonoscopy.

Authors:  Felix W Leung; Joseph W Leung; Surinder K Mann; Shai Friedland; Francisco C Ramirez; Snorri Olafsson
Journal:  J Interv Gastroenterol       Date:  2011-04

9.  Carbon dioxide insufflation during colorectal endoscopic submucosal dissection for patients with obstructive ventilatory disturbance.

Authors:  Masao Yoshida; Kenichiro Imai; Kinichi Hotta; Yuichiro Yamaguchi; Masaki Tanaka; Naomi Kakushima; Kohei Takizawa; Hiroyuki Matsubayashi; Hiroyuki Ono
Journal:  Int J Colorectal Dis       Date:  2013-12-03       Impact factor: 2.571

10.  The water method is effective in difficult colonoscopy - it enhances cecal intubation in unsedated patients with a history of abdominal surgery.

Authors:  Felix W Leung; Surinder K Mann; Joseph W Leung; Rodelei M Siao-Salera; Jackson Guy
Journal:  J Interv Gastroenterol       Date:  2011-10-01
View more